{"id":9823,"date":"2026-02-24T15:11:44","date_gmt":"2026-02-24T07:11:44","guid":{"rendered":"https:\/\/www.packqc.com\/standard\/pstc-16-3\/"},"modified":"2026-04-16T09:59:30","modified_gmt":"2026-04-16T01:59:30","slug":"pstc-16","status":"publish","type":"standard","link":"https:\/\/www.packqc.com\/bg\/standard\/pstc-16\/","title":{"rendered":"PSTC 16"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Understanding PSTC 16 and Loop Tack Testing<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">What is PSCT 16?<\/h3>\n\n\n\n<p><strong data-start=\"946\" data-end=\"957\">PSTC 16<\/strong> is a standard published by the Pressure Sensitive Tape Council (PSTC) that outlines the procedures for measuring the loop tack of pressure-sensitive adhesives. This test evaluates the ability of the adhesive to adhere to a surface under immediate pressure, a crucial factor in determining how well the tape will perform under normal conditions. The <strong data-start=\"1307\" data-end=\"1320\">\u043f\u0440\u0438\u0445\u0432\u0430\u0449\u0430\u043d\u0435 \u043d\u0430 \u043f\u0440\u0438\u043c\u043a\u0430<\/strong> test is a fundamental part of quality assurance for manufacturers of pressure-sensitive tapes, ensuring they meet performance expectations.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What Is the Loop Tack Test?<\/h3>\n\n\n\n<p><strong>\u041f\u0440\u0438\u0445\u0432\u0430\u0449\u0430\u043d\u0435 \u043d\u0430 \u043f\u0440\u0438\u043c\u043a\u0430<\/strong>&nbsp;refers to the force required to separate an adhesive from a substrate immediately after contact. Unlike peel or shear strength, tack measures the&nbsp;<em>instantaneous bond formation<\/em>&nbsp;capability of the adhesive. The&nbsp;<strong>pressure sensitive tape loop tack test<\/strong>&nbsp;simulates real-world scenarios where tapes must adhere swiftly with minimal pressure.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"> PSCT 16 Loop Tack Test Method<\/h2>\n\n\n\n<p>PSTC 16 outlines two distinct methods for performing the loop tack test: Test Method A and Test Method B. Both methods involve forming a loop of adhesive tape, bringing it into contact with a stainless steel panel, and measuring the separation force. The key difference between these methods lies in the testing equipment.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><a href=\"https:\/\/www.packqc.com\/bg\/product\/sale-packaging-tensile-strength-tester-film\/\">\u041c\u0435\u0442\u043e\u0434 \u043d\u0430 \u0438\u0437\u043f\u0438\u0442\u0432\u0430\u043d\u0435 \u0410<br><small>Uses a tensile tester with a 175 mm specimen<\/small><\/a><\/h3>\n\n\n\n<p>In Test Method A, technicians utilize a tensile tester to measure the force required to detach the loop of tape from a surface. This method is precise but can require more setup and calibration.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><a href=\"https:\/\/www.packqc.com\/bg\/product\/ltt-01-loop-tack-tester\/\">\u041c\u0435\u0442\u043e\u0434 \u043d\u0430 \u0438\u0437\u043f\u0438\u0442\u0432\u0430\u043d\u0435 \u0411<br><small>Employs a dedicated loop tack tester with a 125 mm specimen<\/small><\/a><\/h3>\n\n\n\n<p>Test Method B, on the other hand, uses a specialized <b>\u0442\u0435\u0441\u0442\u0435\u0440 \u0437\u0430 \u043f\u0440\u0438\u043c\u043a\u0438<\/b>, such as the LTT-01 from Cell Instruments. This method provides a more straightforward and automated approach, delivering consistent results with minimal operator input. The LTT-01 is specifically designed to meet the requirements of PSTC 16, ensuring compliance with industry standards.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Test Method A vs. Test Method B<\/h3>\n\n\n\n<p>While both methods evaluate loop tack, their equipment and specimen requirements differ:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Aspect<\/strong><\/th><th><strong>\u041c\u0435\u0442\u043e\u0434 \u043d\u0430 \u0438\u0437\u043f\u0438\u0442\u0432\u0430\u043d\u0435 \u0410<\/strong><\/th><th><strong>\u041c\u0435\u0442\u043e\u0434 \u043d\u0430 \u0438\u0437\u043f\u0438\u0442\u0432\u0430\u043d\u0435 \u0411<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Specimen Length<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">175 mm (7 inches)<\/td><td class=\"has-text-align-center\" data-align=\"center\">125 mm (5 inches)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Equipment<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">\u0422\u0435\u0441\u0442\u0435\u0440 \u0437\u0430 \u043e\u043f\u044a\u043d<\/td><td class=\"has-text-align-center\" data-align=\"center\">Loop Tack Tester<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Contact Area<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">625 mm\u00b2 (1 in\u00b2)<\/td><td class=\"has-text-align-center\" data-align=\"center\">625 mm\u00b2 (1 in\u00b2)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>\u041f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">Research &amp; Developmenct<\/td><td class=\"has-text-align-center\" data-align=\"center\">Quality Control &amp; Production<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"has-text-align-center\"><strong>\u041c\u0435\u0442\u043e\u0434 \u043d\u0430 \u0438\u0437\u043f\u0438\u0442\u0432\u0430\u043d\u0435 \u0411<\/strong>&nbsp;is often preferred for routine testing due to its specialized design, which minimizes variability and accelerates workflows.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure Highlights for PSTC 16 Testing<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u041f\u043e\u0434\u0433\u043e\u0442\u043e\u0432\u043a\u0430 \u043d\u0430 \u043f\u0440\u043e\u0431\u0430\u0442\u0430<\/strong>\n<ul class=\"wp-block-list\">\n<li>Cut specimens to the required dimensions (24 mm width).<\/li>\n\n\n\n<li>Condition samples at 23\u00b0C \u00b12\u00b0C and 50% \u00b15% relative humidity for 24 hours.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u041f\u0440\u043e\u0446\u0435\u0434\u0443\u0440\u0430 \u0437\u0430 \u0442\u0435\u0441\u0442\u0432\u0430\u043d\u0435<\/strong>\n<ul class=\"wp-block-list\">\n<li>Clean the stainless steel panel to remove residue.<\/li>\n\n\n\n<li>Form the tape into a loop (adhesive facing outward).<\/li>\n\n\n\n<li>Bring the loop into contact with the panel using controlled force.<\/li>\n\n\n\n<li>Measure the maximum force required to separate the adhesive.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Failure Modes<\/strong>\n<ul class=\"wp-block-list\">\n<li>Adhesive Failure: Separation at the adhesive-substrate interface.<\/li>\n\n\n\n<li>Cohesive Failure: Internal splitting within the adhesive layer.<\/li>\n\n\n\n<li>Adhesive Transfer: Residual adhesive remains on the substrate.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"\u0418\u0437\u043f\u0438\u0442\u0432\u0430\u043d\u0435 \u0437\u0430 \u043f\u0440\u0438\u043b\u0435\u043f\u0432\u0430\u043d\u0435 \u043f\u043e \u043f\u0440\u0438\u043c\u043a\u0430 \u0441\u044a\u0433\u043b\u0430\u0441\u043d\u043e ASTM D6195, PSTC-16, FINAT \u2116 9.\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/L1HbDnq-LxQ?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Choosing the Right Equipment for PSTC 16 Compliance<\/h2>\n\n\n\n<p>For accurate and repeatable results, selecting a&nbsp;<strong>\u0442\u0435\u0441\u0442\u0435\u0440 \u0437\u0430 \u043f\u0440\u0438\u043c\u043a\u0438<\/strong>&nbsp;designed for&nbsp;<strong>PSTC 16<\/strong>&nbsp;\u0435 \u043e\u0442 \u0441\u044a\u0449\u0435\u0441\u0442\u0432\u0435\u043d\u043e \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435. \u0421\u0430\u0439\u0442\u044a\u0442&nbsp;<strong>Cell Instruments LTT-01 Loop Tack Tester<\/strong>&nbsp;\u043e\u0444\u0435\u0440\u0442\u0438:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>7-Inch Touch Screen<\/strong>: Simplifies parameter adjustments and data visualization.<\/li>\n\n\n\n<li><strong>PLC Control &amp; Precision Ball Screw<\/strong>: Ensures consistent test speeds (1\u2013500 mm\/min) and displacements.<\/li>\n\n\n\n<li><strong>Customizable Parameters<\/strong>: Adjust dwell time, stroke, and speed to match PSTC 16 requirements.<\/li>\n\n\n\n<li><strong>Compliant Test Panels<\/strong>: Includes float glass or stainless steel panels for Method A or B.<\/li>\n\n\n\n<li><strong>\u041f\u043e\u0434\u043e\u0431\u0440\u0435\u043d\u0430 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442<\/strong>: Automatic return and limit devices.<\/li>\n\n\n\n<li><strong>Data Accuracy<\/strong>: Microprinter and software integration for traceable reports.<\/li>\n<\/ul>\n\n\n\n<p>This instrument not only streamlines compliance with&nbsp;<strong>PSTC 16<\/strong>&nbsp;but also supports FINAT FTM-9 and ASTM D6195 standards, making it a versatile choice for labs and production facilities.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Key Considerations for Loop Tack Testing<\/h2>\n\n\n\n<p>When performing loop tack testing under PSTC 16, there are several factors to keep in mind:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u041f\u043e\u0434\u0433\u043e\u0442\u043e\u0432\u043a\u0430 \u043d\u0430 \u043f\u043e\u0432\u044a\u0440\u0445\u043d\u043e\u0441\u0442\u0442\u0430<\/strong>: The condition of the substrate can impact test results. Ensure that the surface is clean and free from contaminants.<\/li>\n\n\n\n<li><strong>Tape Type<\/strong>: Different tapes may exhibit varying loop tack values. Choose the appropriate settings on the tester to match the tape&#8217;s specifications.<\/li>\n\n\n\n<li><strong>\u0423\u0441\u043b\u043e\u0432\u0438\u044f \u043d\u0430 \u043e\u043a\u043e\u043b\u043d\u0430\u0442\u0430 \u0441\u0440\u0435\u0434\u0430<\/strong>: Temperature and humidity can influence the performance of pressure-sensitive tapes. Conduct tests in a controlled environment for the best results.<\/li>\n<\/ul>\n\n\n\n<p>By using equipment like the LTT-01, manufacturers can easily control these variables and ensure consistent, reliable testing results.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Contact Us Get <a href=\"https:\/\/www.packqc.com\/bg\/applications\/loop-tack-test-method\/\">Loop Tack Testing Solution<\/a><\/h2>\n\n\n\n<p><strong><a href=\"https:\/\/pstc.org\/pstc-announces-16th-edition-of-test-methods-for-pressure-sensitive-adhesive-tapes\/\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">PSTC 16<\/a><\/strong>\u00a0\u0435 \u043e\u0441\u043d\u043e\u0432\u0435\u043d \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442 \u0437\u0430 \u043e\u0446\u0435\u043d\u043a\u0430 \u043d\u0430 <strong>\u043b\u0435\u043f\u0438\u043b\u0430, \u0447\u0443\u0432\u0441\u0442\u0432\u0438\u0442\u0435\u043b\u043d\u0438 \u043d\u0430 \u043d\u0430\u0442\u0438\u0441\u043a<\/strong> \u043a\u0430\u0442\u043e \u0438\u0437\u043f\u043e\u043b\u0437\u0432\u0430\u0442\u0435 <strong>\u041c\u0435\u0442\u043e\u0434 \u0437\u0430 \u0438\u0437\u043f\u0438\u0442\u0432\u0430\u043d\u0435 \u043d\u0430 \u043f\u0440\u0438\u043b\u0435\u043f\u0432\u0430\u043d\u0435 \u043d\u0430 \u043f\u0440\u0438\u043c\u043a\u0430<\/strong>. \u041f\u0440\u0438 \u0441\u043f\u0430\u0437\u0432\u0430\u043d\u0435 \u043d\u0430 \u043f\u0440\u0430\u0432\u0438\u043b\u043d\u0438\u0442\u0435 \u043f\u0440\u043e\u0446\u0435\u0434\u0443\u0440\u0438 \u0438 \u0438\u0437\u043f\u043e\u043b\u0437\u0432\u0430\u043d\u0435 \u043d\u0430 <strong>\u0442\u0435\u0441\u0442\u0435\u0440 \u0437\u0430 \u043f\u0440\u0438\u043c\u043a\u0438<\/strong>, \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0438\u0442\u0435 \u043c\u043e\u0433\u0430\u0442 \u0434\u0430 \u0433\u0430\u0440\u0430\u043d\u0442\u0438\u0440\u0430\u0442 <strong>\u0432\u0438\u0441\u043e\u043a\u043e \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u043e \u043d\u0430 \u0437\u0430\u043b\u0435\u043f\u0432\u0430\u043d\u0435<\/strong>. \u0417\u0430 \u0443\u0441\u044a\u0432\u044a\u0440\u0448\u0435\u043d\u0441\u0442\u0432\u0430\u043d\u0438 \u0440\u0435\u0448\u0435\u043d\u0438\u044f \u0437\u0430 \u0438\u0437\u043f\u0438\u0442\u0432\u0430\u043d\u0435, <strong>Cell Instruments\u2019 \u0422\u0435\u0441\u0442\u0435\u0440 \u0437\u0430 \u043f\u0440\u0438\u043b\u0435\u043f\u0432\u0430\u043d\u0435 \u043d\u0430 \u043a\u043e\u043d\u0442\u0443\u0440<\/strong> \u0435 \u0432\u043e\u0434\u0435\u0449 \u0438\u0437\u0431\u043e\u0440 \u0432 \u0438\u043d\u0434\u0443\u0441\u0442\u0440\u0438\u044f\u0442\u0430.<\/p>","protected":false},"excerpt":{"rendered":"<p>Understanding PSTC 16 and Loop Tack Testing What is PSCT 16? PSTC 16 is a standard published by the Pressure Sensitive Tape Council (PSTC) that outlines the procedures for measuring the loop tack of pressure-sensitive adhesives. This test evaluates the ability of the adhesive to adhere to a surface under immediate pressure, a crucial factor [&hellip;]<\/p>","protected":false},"featured_media":5229,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"standard-category":[614],"class_list":["post-9823","standard","type-standard","status-publish","has-post-thumbnail","hentry","standard-category-pstc"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/bg\/wp-json\/wp\/v2\/standard\/9823","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/bg\/wp-json\/wp\/v2\/standard"}],"about":[{"href":"https:\/\/www.packqc.com\/bg\/wp-json\/wp\/v2\/types\/standard"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/bg\/wp-json\/wp\/v2\/media\/5229"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/bg\/wp-json\/wp\/v2\/media?parent=9823"}],"wp:term":[{"taxonomy":"standard-category","embeddable":true,"href":"https:\/\/www.packqc.com\/bg\/wp-json\/wp\/v2\/standard-category?post=9823"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}