{"id":9585,"date":"2026-02-02T14:53:24","date_gmt":"2026-02-02T06:53:24","guid":{"rendered":"https:\/\/www.packqc.com\/products\/break-loose-force-and-glide-force-tester\/"},"modified":"2026-04-16T15:26:12","modified_gmt":"2026-04-16T07:26:12","slug":"break-loose-force-and-glide-force-tester","status":"publish","type":"products","link":"https:\/\/www.packqc.com\/bs\/products\/break-loose-force-and-glide-force-tester\/","title":{"rendered":"SSR-01 Klizni otporni tester za \u0161pricu"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Testiranje sile okidanja i klizanja<\/h2>\n\n\n\n<p>U evaluaciji performansi \u0161price, <strong data-start=\"496\" data-end=\"535\">testiranje sile okidanja i klizanja<\/strong> Igra klju\u010dnu ulogu u procjeni glatko\u0107e i pouzdanosti kretanja klipa. Ovaj test odre\u0111uje silu potrebnu za pokretanje i odr\u017eavanje kretanja klipa \u0161price, osiguravaju\u0107i dosljednu primjenu lijeka i sigurnost pacijenta.<\/p>\n\n\n\n<p>Cell Instruments, vode\u0107i proizvo\u0111a\u010d <strong data-start=\"826\" data-end=\"857\">oprema za ispitivanje materijala<\/strong>, pru\u017ea napredne <strong data-start=\"877\" data-end=\"925\">Ma\u0161ine za ispitivanje osloba\u0111aju\u0107e i klizne sile<\/strong> dizajniran prema <em data-start=\"948\" data-end=\"960\">ISO 7886-1<\/em> standardi. Ovi instrumenti poma\u017eu proizvo\u0111a\u010dima, laboratorijama i stru\u010dnjacima za kontrolu kvaliteta da osiguraju da njihove \u0161price zadovoljavaju me\u0111unarodne zahtjeve za kvalitet i performanse.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">ISO 7886-1 i performanse \u0161price<\/h2>\n\n\n\n<p>Me\u0111unarodni standard <strong data-start=\"1233\" data-end=\"1247\">ISO 7886-1<\/strong> odre\u0111uje zahtjeve i metode ispitivanja za sterilne hipodermijske \u0161price za jednokratnu upotrebu. Prilog E standarda iznosi <strong data-start=\"1377\" data-end=\"1450\">metoda ispitivanja za odre\u0111ivanje sila potrebnih za rad klipa<\/strong>, uklju\u010duju\u0107i oba <em data-start=\"1467\" data-end=\"1486\">prekinuti silu<\/em> i <em data-start=\"1491\" data-end=\"1506\">gla\u0111aju\u0107a sila<\/em>.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"1513\" data-end=\"1534\">Slobodna sila<\/strong> odnosi se na <em data-start=\"1549\" data-end=\"1564\">po\u010detna sila<\/em> Potrebno za pokretanje klipa.<\/li>\n\n\n\n<li><strong data-start=\"1609\" data-end=\"1626\">Glavna sila<\/strong> predstavlja <em data-start=\"1642\" data-end=\"1660\">kontinuirana sila<\/em> bilo je potrebno odr\u017eavati kretanje klipa tokom cijelog hoda.<\/li>\n<\/ul>\n\n\n\n<p>Ova dva parametra su klju\u010dni pokazatelji kvaliteta \u0161price, uti\u010du\u0107i na udobnost korisnika, preciznost injekcije i stabilnost protoka lijeka. Prekomjerni ili neujedna\u010deni pritisci mogu dovesti do trzavog kretanja, gre\u0161aka u doziranju ili \u010dak do kvara \u0161price.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Princip testiranja na lom i kliznu silu<br><small> \u2014\u2014 ISO 7886-1 Aneks E<\/small><\/h2>\n\n\n\n<p>The <strong data-start=\"2029\" data-end=\"2068\">testiranje sile okidanja i klizanja<\/strong> proces koristi <strong data-start=\"2084\" data-end=\"2114\">mehani\u010dki ispitni stroj<\/strong> gurnuti kliza\u010d \u0161price dok se mjeri i bilje\u017ei primijenjena sila. Test procjenjuje koliko glatko kliza\u010d radi pod standardiziranim uvjetima, kao \u0161to su temperatura i brzina pomaka.<\/p>\n\n\n\n<p>Tokom testa:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u0160prica je napunjena vodom koja se odr\u017eava na <em data-start=\"2392\" data-end=\"2404\">(23 \u00b1 5)\u00b0C<\/em>.<\/li>\n\n\n\n<li>Mlaznica \u0161price se povezuje s rezervoarom vode na kontroliranom nivou.<\/li>\n\n\n\n<li>Testna ma\u0161ina pomjera kliza\u010d konstantnom brzinom od <em data-start=\"2548\" data-end=\"2568\">(100 \u00b1 5) mm\/min).<\/em><\/li>\n\n\n\n<li>Sistem bilje\u017ei:\n<ul class=\"wp-block-list\">\n<li>The <strong data-start=\"2605\" data-end=\"2631\">osloboditi silu (Fs)<\/strong> \u2013 sila potrebna za pokretanje klipa.<\/li>\n\n\n\n<li>The <strong data-start=\"2686\" data-end=\"2712\">prosje\u010dna sila klizanja (F)<\/strong> \u2013 prosje\u010dna sila tokom stalnog kretanja klipa.<\/li>\n\n\n\n<li>The <strong data-start=\"2772\" data-end=\"2796\">maksimalna sila (Fmax)<\/strong> \u2013 vr\u0161na sila zabilje\u017eena tokom pokreta.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<p>Ovi parametri su prikazani kao a <em style=\"font-size: 16px;\" data-start=\"2873\" data-end=\"2899\">kriva sila-pomak<\/em>, pru\u017eaju\u0107i jasnu vizualizaciju karakteristika performansi \u0161price.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">SSR-01 Klizni otporni tester za \u0161pricu<\/h2>\n\n\n\n<p>Cell Instruments nudi precizno projektovane <strong data-start=\"3081\" data-end=\"3129\">Ma\u0161ine za ispitivanje osloba\u0111aju\u0107e i klizne sile<\/strong> koji se pridr\u017eavaju <em data-start=\"3147\" data-end=\"3159\">ISO 7886-1<\/em> i povezani standardi za farmaceutska ispitivanja.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Klju\u010dne zna\u010dajke uklju\u010duju:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"3598\" data-end=\"3616\">Visoka preciznost<\/strong>: Prisilite na preciznost do <strong data-start=\"3639\" data-end=\"3647\">0.5%<\/strong> od \u010ditanja u punom opsegu.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3673\" data-end=\"3698\">\u0160irok raspon brzina testiranja<\/strong>: Podesivo od <strong style=\"font-size: 16px;\" data-start=\"3716\" data-end=\"3735\">1 do 500 mm\/min<\/strong> da se prilagodi razli\u010ditim uslovima testiranja.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3778\" data-end=\"3805\">Mjerenje triju sila<\/strong>Automatski bilje\u017ei silu odvajanja, prosje\u010dnu kliznu silu i maksimalnu silu.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3888\" data-end=\"3915\">Korisni\u010dko su\u010delje<\/strong>: <strong style=\"font-size: 16px;\" data-start=\"3917\" data-end=\"3935\">PLC-om upravljano<\/strong> sa <strong style=\"font-size: 16px;\" data-start=\"3943\" data-end=\"3969\">7-in\u010dni HMI ekran osjetljiv na dodir<\/strong> za besprijekoran rad.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3996\" data-end=\"4016\">Ugra\u0111eni \u0161tampa\u010d<\/strong>: Pru\u017ea trenutne rezultate testa za dokumentaciju i osiguranje kvaliteta.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"4093\" data-end=\"4116\">Za\u0161tita od preoptere\u0107enja<\/strong>: Osigurava dugoro\u010dnu izdr\u017eljivost i sigurnost operatera.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Glavni parametar<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Load Cell<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">200N (ili prema potrebi)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Test Speed<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">1~500 mm\/min<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Preciznost<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">0.01mm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Snaga<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">110~220V<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Primjene i utjecaj na industriju<\/h2>\n\n\n\n<p>Testiranje sile odvajanja i sile klizanja je klju\u010dno u vi\u0161e sektora:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"4294\" data-end=\"4313\">Medicinski ure\u0111aji<\/strong>: Osigurava sigurnost i upotrebljivost \u0161price za zdravstvene radnike i pacijente.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"4397\" data-end=\"4416\">Pharmaceuticals<\/strong>: Provjerava dosljednost proizvoda prije distribucije.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"4470\" data-end=\"4492\">Regulatorno testiranje<\/strong>: Pru\u017ea podatke potrebne za uskla\u0111enost s <strong style=\"font-size: 16px;\" data-start=\"4538\" data-end=\"4560\"><a href=\"https:\/\/www.iso.org\/standard\/64790.html\" target=\"_blank\" rel=\"noopener nofollow\">ISO 7886-1<\/a> testiranje<\/strong> zahtjevi.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"4577\" data-end=\"4596\">Kontrola kvaliteta<\/strong>: Poma\u017ee proizvo\u0111a\u010dima da odr\u017ee visoke standarde proizvodnje i smanje stopu gre\u0161aka.<\/li>\n<\/ul>\n\n\n\n<p>Zahvaljuju\u0107i preciznosti i pridr\u017eavanju ISO protokola, SSR-01 je idealan za <strong data-start=\"4759\" data-end=\"4810\">proizvo\u0111a\u010di \u0161prica, farmaceutske kompanije<\/strong>, i <strong data-start=\"4816\" data-end=\"4847\">agencije za kontrolu kvaliteta<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Za\u0161to odabrati \u0107elijske instrumente?<\/h2>\n\n\n\n<p>Kao iskusni proizvo\u0111a\u010d specijaliziran za <strong data-start=\"4456\" data-end=\"4491\">ispitivanje materijala i automatizacija<\/strong>, Cell Instruments pru\u017ea potpuna rje\u0161enja za <strong data-start=\"4542\" data-end=\"4589\">Testiranje sile odvajanja i klizanja \u0161price<\/strong>. Mi kombinujemo visokoprecizno in\u017eenjerstvo, prilagodljivi softver i stru\u010dnu tehni\u010dku podr\u0161ku kako bismo pomogli klijentima da zadovolje stroge industrijske standarde.<\/p>\n\n\n\n<p><strong data-start=\"4962\" data-end=\"5001\">Testiranje sile okidanja i klizanja<\/strong> je bitan dio provjere kvaliteta \u0161price u skladu s <em data-start=\"5068\" data-end=\"5080\">ISO 7886-1<\/em>. To direktno utje\u010de na upotrebljivost, sigurnost i uskla\u0111enost s propisima. Kori\u0161tenjem profesionalnih instrumenata za testiranje od <strong data-start=\"5195\" data-end=\"5215\">Cell Instruments<\/strong>, Laboratorije i proizvo\u0111a\u010di mogu posti\u0107i pouzdane, ta\u010dne i reproducibilne rezultate\u2014pobolj\u0161avaju\u0107i i performanse proizvoda i povjerenje kupaca.<\/p>","protected":false},"excerpt":{"rendered":"<p>Testovi otpora pri otpu\u0161tanju i klizanju mjere silu potrebnu za pokretanje i odr\u017eavanje kretanja klipa \u0161price.<\/p>","protected":false},"featured_media":5356,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"product-category":[454,438,495,593],"product-tag":[],"class_list":["post-9585","products","type-products","status-publish","has-post-thumbnail","hentry","product-category-custom-lab-testing-instruments-manufacturer","product-category-medical-and-pharmaceutical-testing","product-category-pharmaceutical-testing","product-category-syringe-testing"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/bs\/wp-json\/wp\/v2\/products\/9585","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/bs\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.packqc.com\/bs\/wp-json\/wp\/v2\/types\/products"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/bs\/wp-json\/wp\/v2\/media\/5356"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/bs\/wp-json\/wp\/v2\/media?parent=9585"}],"wp:term":[{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/www.packqc.com\/bs\/wp-json\/wp\/v2\/product-category?post=9585"},{"taxonomy":"product-tag","embeddable":true,"href":"https:\/\/www.packqc.com\/bs\/wp-json\/wp\/v2\/product-tag?post=9585"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}