{"id":9583,"date":"2026-02-02T14:53:24","date_gmt":"2026-02-02T06:53:24","guid":{"rendered":"https:\/\/www.packqc.com\/products\/syringe-leak-testing-machine\/"},"modified":"2026-04-16T15:11:39","modified_gmt":"2026-04-16T07:11:39","slug":"syringe-leak-testing-machine","status":"publish","type":"products","link":"https:\/\/www.packqc.com\/cs\/products\/syringe-leak-testing-machine\/","title":{"rendered":"SLT-02 Tester t\u011bsnosti st\u0159\u00edka\u010dek"},"content":{"rendered":"<p>Testov\u00e1n\u00ed t\u011bsnosti injek\u010dn\u00edch st\u0159\u00edka\u010dek je kl\u00ed\u010dov\u00fdm procesem pro zaji\u0161t\u011bn\u00ed kvality a bezpe\u010dnosti injek\u010dn\u00edch st\u0159\u00edka\u010dek pou\u017e\u00edvan\u00fdch v r\u016fzn\u00fdch l\u00e9ka\u0159sk\u00fdch a farmaceutick\u00fdch aplikac\u00edch. Stroj na testov\u00e1n\u00ed t\u011bsnosti injek\u010dn\u00edch st\u0159\u00edka\u010dek hraje z\u00e1sadn\u00ed roli p\u0159i zji\u0161\u0165ov\u00e1n\u00ed \u00faniku vzduchu za z\u00e1tku p\u00edstu a zaji\u0161\u0165uje neporu\u0161enost t\u011bsn\u011bn\u00ed injek\u010dn\u00ed st\u0159\u00edka\u010dky.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Co je testov\u00e1n\u00ed t\u011bsnosti st\u0159\u00edka\u010dek?<\/h2>\n\n\n\n<p>Zkou\u0161ka t\u011bsnosti st\u0159\u00edka\u010dky se prov\u00e1d\u00ed za \u00fa\u010delem ov\u011b\u0159en\u00ed, zda z\u00e1tka p\u00edstu st\u0159\u00edka\u010dky a t\u011bsn\u011bn\u00ed nedovoluj\u00ed \u00fanik vzduchu za ur\u010dit\u00fdch tlakov\u00fdch podm\u00ednek. Tato zkou\u0161ka zaji\u0161\u0165uje, \u017ee st\u0159\u00edka\u010dky net\u011bsn\u00ed, co\u017e by mohlo ohrozit jejich funk\u010dnost, zejm\u00e9na u aplikac\u00ed, kde je nejd\u016fle\u017eit\u011bj\u0161\u00ed p\u0159esnost a sterilita, jako jsou injekce inzul\u00ednu nebo vakc\u00edny.<\/p>\n\n\n\n<p>P\u0159i zkou\u0161ce t\u011bsnosti se injek\u010dn\u00ed st\u0159\u00edka\u010dka \u010d\u00e1ste\u010dn\u011b napln\u00ed destilovanou vodou a vakuem se otestuje neporu\u0161enost t\u011bsn\u011bn\u00ed a z\u00e1tky p\u00edstu. Pokud p\u0159es tyto sou\u010d\u00e1sti unik\u00e1 vzduch, znamen\u00e1 to, \u017ee st\u0159\u00edka\u010dka nemus\u00ed spl\u0148ovat po\u017eadovan\u00e9 standardy kvality.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">P\u0159ehled syst\u00e9mu pro testov\u00e1n\u00ed t\u011bsnosti st\u0159\u00edka\u010dek<\/h2>\n\n\n\n<p>The <strong>SLT-02 Tester t\u011bsnosti st\u0159\u00edka\u010dek<\/strong> se skl\u00e1d\u00e1 z u\u017eivatelsky p\u0159\u00edv\u011btiv\u00e9 \u0159\u00eddic\u00ed jednotky, stojanu na st\u0159\u00edka\u010dku a trubi\u010dky pro upevn\u011bn\u00ed st\u0159\u00edka\u010dky b\u011bhem testu. Syst\u00e9m funguje tak, \u017ee se do \u0159\u00eddic\u00ed jednotky p\u0159iv\u00e1d\u00ed stla\u010den\u00fd vzduch, kter\u00fd pomoc\u00ed Venturiho trubice vytv\u00e1\u0159\u00ed p\u0159esn\u00fd podtlak uvnit\u0159 st\u0159\u00edka\u010dky. Konstrukce syst\u00e9mu zaji\u0161\u0165uje stabiln\u00ed udr\u017eov\u00e1n\u00ed vakua po celou dobu testov\u00e1n\u00ed a poskytuje p\u0159esn\u00e9 a opakovateln\u00e9 v\u00fdsledky.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Kl\u00ed\u010dov\u00e9 vlastnosti<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Stabiln\u00ed dr\u017een\u00ed vakua<\/strong>: SLT-02 zaji\u0161\u0165uje st\u00e1l\u00fd podtlak po celou dobu testu, aby bylo mo\u017en\u00e9 p\u0159esn\u011b zjistit p\u0159\u00edpadn\u00fd \u00fanik vzduchu nebo uvoln\u011bn\u00ed z\u00e1tky p\u00edstu.<\/li>\n\n\n\n<li><strong>\u00da\u010dinn\u00e1 v\u00fdroba vakua<\/strong>: Stroj \u00fa\u010dinn\u011b vytv\u00e1\u0159\u00ed pot\u0159ebn\u00fd podtlak a udr\u017euje po\u017eadovan\u00e9 zku\u0161ebn\u00ed podm\u00ednky bez p\u0159eru\u0161en\u00ed.<\/li>\n\n\n\n<li><strong>Nastaviteln\u00e1 sv\u00edtidla<\/strong>: Upevn\u011bn\u00ed st\u0159\u00edka\u010dky lze snadno nastavit tak, aby se do n\u011bj ve\u0161ly st\u0159\u00edka\u010dky r\u016fzn\u00fdch objem\u016f, tak\u017ee SLT-02 je univerz\u00e1ln\u00ed pro r\u016fzn\u00e9 typy a velikosti st\u0159\u00edka\u010dek.<\/li>\n\n\n\n<li><strong>U\u017eivatelsky p\u0159\u00edv\u011btiv\u00fd provoz<\/strong>: P\u0159\u00edstroj SLT-02 je navr\u017een pro snadn\u00e9 pou\u017eit\u00ed, s jednoduch\u00fdm nastaven\u00edm a automatick\u00fdm provozem po zah\u00e1jen\u00ed testu.<\/li>\n\n\n\n<li><strong>Trvanliv\u00e1 \u017eivotnost<\/strong>: Model SLT-02 je zkonstruov\u00e1n pro dlouhodob\u00e9 pou\u017e\u00edv\u00e1n\u00ed, je odoln\u00fd a spolehliv\u00fd a zaji\u0161\u0165uje dlouhodob\u00fd v\u00fdkon s minim\u00e1ln\u00edmi n\u00e1roky na \u00fadr\u017ebu.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Technick\u00e1 vlastnost<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Testovac\u00ed rozsah<\/strong><\/td><td>0~-90KPa<\/td><\/tr><tr><td><strong>Vstup vzduchu<\/strong><\/td><td>0,6 ~ 0,7 Mpa<\/td><\/tr><tr><td><strong>\u010cas testu<\/strong><\/td><td>9999H<\/td><\/tr><tr><td><strong>Moc<\/strong><\/td><td>220V<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Konfigurace<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0158\u00eddic\u00ed jednotka testeru t\u011bsnosti SLT-02<\/strong><\/li>\n\n\n\n<li><strong>Stojan na injek\u010dn\u00ed st\u0159\u00edka\u010dky<\/strong><\/li>\n\n\n\n<li><strong>Hadi\u010dka pro p\u0159ipojen\u00ed st\u0159\u00edka\u010dky<\/strong><\/li>\n\n\n\n<li><strong>Nap\u00e1jec\u00ed kabel<\/strong><\/li>\n\n\n\n<li><strong>Pojistka<\/strong><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Princip zkou\u0161ky net\u011bsnosti st\u0159\u00edka\u010dky Testovac\u00ed stroj<\/h2>\n\n\n\n<p>Proces testov\u00e1n\u00ed za\u010d\u00edn\u00e1 p\u0159ipojen\u00edm trysky st\u0159\u00edka\u010dky ke kompatibiln\u00ed p\u0159ipojovac\u00ed hadi\u010dce. Pot\u00e9 se st\u0159\u00edka\u010dka \u010d\u00e1ste\u010dn\u011b napln\u00ed vodou. Prost\u0159ednictv\u00edm trysky se vytvo\u0159\u00ed \u0159\u00edzen\u00fd podtlak, \u010d\u00edm\u017e se uvnit\u0159 st\u0159\u00edka\u010dky vytvo\u0159\u00ed vakuum. Syst\u00e9m pot\u00e9 sleduje, zda st\u0159\u00edka\u010dka neunik\u00e1 vzduchem p\u0159es z\u00e1tku p\u00edstu nebo t\u011bsn\u011bn\u00ed. D\u00e1le vyhodnocuje, zda se z\u00e1tka p\u00edstu neodd\u011bluje od p\u00edstu. Tento proces simuluje re\u00e1ln\u00e9 podm\u00ednky, kdy st\u0159\u00edka\u010dky mus\u00ed z\u016fstat ut\u011bsn\u011bn\u00e9 a funk\u010dn\u00ed p\u0159i r\u016fzn\u00fdch tlac\u00edch.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">V\u00fdhody st\u0159\u00edka\u010dek pro testov\u00e1n\u00ed t\u011bsnosti<\/h2>\n\n\n\n<p>Stroje pro testov\u00e1n\u00ed t\u011bsnosti st\u0159\u00edka\u010dek nab\u00edzej\u00ed n\u011bkolik v\u00fdhod, zejm\u00e9na pro v\u00fdrobce a pracovn\u00edky kontroly kvality:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>P\u0159esnost a p\u0159esnost<\/strong>: Tyto stroje poskytuj\u00ed velmi p\u0159esn\u00e9 v\u00fdsledky a zaji\u0161\u0165uj\u00ed, aby st\u0159\u00edka\u010dky netekly a spl\u0148ovaly normy ISO.<\/li>\n\n\n\n<li><strong>Zaji\u0161t\u011bn\u00ed kvality<\/strong>: P\u0159\u00edstroj detekuje i ty nejmen\u0161\u00ed net\u011bsnosti a pom\u00e1h\u00e1 tak zajistit, aby st\u0159\u00edka\u010dky byly bezpe\u010dn\u00e9 pro pou\u017eit\u00ed p\u0159i l\u00e9ka\u0159sk\u00fdch z\u00e1kroc\u00edch.<\/li>\n\n\n\n<li><strong>Dodr\u017eov\u00e1n\u00ed<\/strong>: Stroje pro testov\u00e1n\u00ed t\u011bsnosti st\u0159\u00edka\u010dek pom\u00e1haj\u00ed v\u00fdrobc\u016fm dodr\u017eovat normy ISO 7886-1, kter\u00e9 jsou z\u00e1sadn\u00ed pro z\u00edsk\u00e1n\u00ed certifikace a zaji\u0161t\u011bn\u00ed kvality jejich v\u00fdrobk\u016f.<\/li>\n\n\n\n<li><strong>\u00da\u010dinnost<\/strong>: Automatizovan\u00e9 testovac\u00ed syst\u00e9my zefektiv\u0148uj\u00ed proces testov\u00e1n\u00ed, umo\u017e\u0148uj\u00ed vy\u0161\u0161\u00ed propustnost a sni\u017euj\u00ed po\u010det lidsk\u00fdch chyb.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">ISO 7886-1 Zku\u0161ebn\u00ed metoda \u00faniku vzduchu<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">ISO 7886-1 P\u0159\u00edloha B<\/h3>\n\n\n\n<p><a href=\"https:\/\/www.packqc.com\/cs\/product-category\/iso\/iso-7886-1\/\" target=\"_blank\" rel=\"noopener\"><strong>ISO 7886-1<\/strong><\/a> je mezin\u00e1rodn\u00ed norma, kter\u00e1 stanov\u00ed specifikace pro steriln\u00ed injek\u010dn\u00ed st\u0159\u00edka\u010dky, v\u010detn\u011b pokyn\u016f pro. <strong>testov\u00e1n\u00ed \u00faniku vzduchu<\/strong>. Konkr\u00e9tn\u011b, <strong>ISO 7886-1 P\u0159\u00edloha B<\/strong> poskytuje podrobnou zku\u0161ebn\u00ed metodu pro zji\u0161\u0165ov\u00e1n\u00ed \u00faniku vzduchu kolem z\u00e1tky p\u00edstu st\u0159\u00edka\u010dky b\u011bhem aspirace, co\u017e je z\u00e1sadn\u00ed pro zaji\u0161t\u011bn\u00ed funk\u010dnosti st\u0159\u00edka\u010dky.<\/p>\n\n\n\n<p>Key elements of ISO 7886-1 testing include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Zku\u0161ebn\u00ed za\u0159\u00edzen\u00ed<\/strong>: Zku\u0161ebn\u00ed za\u0159\u00edzen\u00ed zahrnuje vakuov\u00fd syst\u00e9m, manometr, vakuov\u011b t\u011bsn\u00e9 ventily a svorku pro uchycen\u00ed injek\u010dn\u00ed st\u0159\u00edka\u010dky.<\/li>\n\n\n\n<li><strong>Testovac\u00ed podm\u00ednky<\/strong>: Injek\u010dn\u00ed st\u0159\u00edka\u010dka je vystavena vakuov\u00e9mu prost\u0159ed\u00ed, kter\u00e9 simuluje podm\u00ednky, jim\u017e by musela \u010delit b\u011bhem pou\u017e\u00edv\u00e1n\u00ed. P\u0159i zkou\u0161ce se sleduje schopnost p\u00edstu z\u016fstat p\u0159ipojen a zda vzduch neunik\u00e1 p\u0159es t\u011bsn\u011bn\u00ed.<\/li>\n\n\n\n<li><strong>Zpr\u00e1va o zkou\u0161ce<\/strong>: V\u00fdsledky mus\u00ed b\u00fdt zdokumentov\u00e1ny, v\u010detn\u011b identifikace st\u0159\u00edka\u010dky, v\u00fdskytu net\u011bsnosti, p\u0159\u00edpadn\u00fdch zm\u011bn tlaku a toho, zda se odd\u011blila z\u00e1tka p\u00edstu.<\/li>\n<\/ul>\n\n\n\n<p>Tato norma zaji\u0161\u0165uje, \u017ee injek\u010dn\u00ed st\u0159\u00edka\u010dky spl\u0148uj\u00ed nezbytn\u00e1 krit\u00e9ria pro l\u00e9ka\u0159sk\u00e9 pou\u017eit\u00ed, a chr\u00e1n\u00ed tak pacienty i zdravotnick\u00e9 pracovn\u00edky.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Proces testov\u00e1n\u00ed<\/h2>\n\n\n\n<p>The <strong>zkou\u0161ka \u00faniku vzduchu<\/strong> je standardn\u00ed postup pou\u017e\u00edvan\u00fd p\u0159i testov\u00e1n\u00ed t\u011bsnosti injek\u010dn\u00edch st\u0159\u00edka\u010dek. Podle <strong>ISO 7886-1<\/strong>, tato metoda spo\u010d\u00edv\u00e1 v aplikaci podtlaku na injek\u010dn\u00ed st\u0159\u00edka\u010dku a m\u011b\u0159en\u00ed zm\u011bny tlaku v pr\u016fb\u011bhu \u010dasu. Zde je stru\u010dn\u00fd p\u0159ehled typick\u00fdch krok\u016f:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Pln\u011bn\u00ed st\u0159\u00edka\u010dky<\/strong>: St\u0159\u00edka\u010dka se napln\u00ed destilovanou vodou, obvykle nejm\u00e9n\u011b 25% jej\u00edho jmenovit\u00e9ho objemu.<\/li>\n\n\n\n<li><strong>Pou\u017eit\u00ed vakua<\/strong>: Injek\u010dn\u00ed st\u0159\u00edka\u010dka je p\u0159ipojena k vakuov\u00e9mu syst\u00e9mu, kter\u00fd vytv\u00e1\u0159\u00ed \u0159\u00edzen\u00fd podtlak, obvykle dosahuj\u00edc\u00ed 88 kPa pod okoln\u00ed atmosf\u00e9rick\u00fd tlak.<\/li>\n\n\n\n<li><strong>Pozorov\u00e1n\u00ed na \u00faniky<\/strong>: Pot\u00e9 se st\u0159\u00edka\u010dka zkontroluje, zda nedoch\u00e1z\u00ed k \u00faniku vzduchu p\u0159es z\u00e1tku p\u00edstu nebo t\u011bsn\u011bn\u00ed. Na manometru se kontroluje, zda nedoch\u00e1z\u00ed k poklesu tlaku, kter\u00fd by nazna\u010doval net\u011bsnost.<\/li>\n\n\n\n<li><strong>Zkou\u0161ka odpojen\u00ed plun\u017eru<\/strong>: Zkou\u0161kou se rovn\u011b\u017e zji\u0161\u0165uje, zda se z\u00e1tka p\u00edstu neodd\u011bluje od p\u00edstu ve vakuu.<\/li>\n<\/ol>\n\n\n\n<p>Tato metoda umo\u017e\u0148uje spolehliv\u011b posoudit, zda jsou t\u011bsn\u011bn\u00ed st\u0159\u00edka\u010dky a z\u00e1tka p\u00edstu neporu\u0161en\u00e9 a funk\u010dn\u00ed.<\/p>\n\n\n\n<p>The <strong>SLT-02 Tester t\u011bsnosti st\u0159\u00edka\u010dek<\/strong> je nezbytn\u00fdm n\u00e1strojem pro v\u00fdrobce injek\u010dn\u00edch st\u0159\u00edka\u010dek a t\u00fdmy kontroly kvality, kter\u00e9 pot\u0159ebuj\u00ed zajistit, aby jejich injek\u010dn\u00ed st\u0159\u00edka\u010dky byly net\u011bsn\u00e9 a spl\u0148ovaly po\u017eadovan\u00e9 mezin\u00e1rodn\u00ed normy, jako jsou nap\u0159. <strong><a href=\"https:\/\/www.iso.org\/standard\/64790.html\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">ISO 7886-1<\/a> P\u0159\u00edloha B<\/strong>. Toto spolehliv\u00e9 a efektivn\u00ed testovac\u00ed \u0159e\u0161en\u00ed zaru\u010duje integritu injek\u010dn\u00edch st\u0159\u00edka\u010dek a je nepostradatelnou sou\u010d\u00e1st\u00ed procesu zaji\u0161t\u011bn\u00ed kvality v l\u00e9ka\u0159sk\u00e9m a farmaceutick\u00e9m pr\u016fmyslu.<\/p>","protected":false},"excerpt":{"rendered":"<p>Syringe leak testing is a crucial process in ensuring the quality and safety of hypodermic syringes used in various medical and pharmaceutical applications.<\/p>","protected":false},"featured_media":5336,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"product-category":[434,437,484,438,495,593,517],"product-tag":[],"class_list":["post-9583","products","type-products","status-publish","has-post-thumbnail","hentry","product-category-iso","product-category-iso-7886-1","product-category-leak-testing","product-category-medical-and-pharmaceutical-testing","product-category-pharmaceutical-testing","product-category-syringe-testing","product-category-vacuum-leak-tester"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/cs\/wp-json\/wp\/v2\/products\/9583","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/cs\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.packqc.com\/cs\/wp-json\/wp\/v2\/types\/products"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/cs\/wp-json\/wp\/v2\/media\/5336"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/cs\/wp-json\/wp\/v2\/media?parent=9583"}],"wp:term":[{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/www.packqc.com\/cs\/wp-json\/wp\/v2\/product-category?post=9583"},{"taxonomy":"product-tag","embeddable":true,"href":"https:\/\/www.packqc.com\/cs\/wp-json\/wp\/v2\/product-tag?post=9583"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}