{"id":9585,"date":"2026-02-02T14:53:24","date_gmt":"2026-02-02T06:53:24","guid":{"rendered":"https:\/\/www.packqc.com\/products\/break-loose-force-and-glide-force-tester\/"},"modified":"2026-04-16T15:26:12","modified_gmt":"2026-04-16T07:26:12","slug":"break-loose-force-and-glide-force-tester","status":"publish","type":"products","link":"https:\/\/www.packqc.com\/cs\/products\/break-loose-force-and-glide-force-tester\/","title":{"rendered":"Tester posuvn\u00e9ho odporu st\u0159\u00edka\u010dky SSR-01"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Testov\u00e1n\u00ed s\u00edly p\u0159i p\u0159etr\u017een\u00ed a klouz\u00e1n\u00ed<\/h2>\n\n\n\n<p>P\u0159i hodnocen\u00ed v\u00fdkonu injek\u010dn\u00ed st\u0159\u00edka\u010dky, <strong data-start=\"496\" data-end=\"535\">uvoln\u011bte se a testujte klouzavou s\u00edlu<\/strong> hraje kl\u00ed\u010dovou roli p\u0159i posuzov\u00e1n\u00ed plynulosti a spolehlivosti pohybu p\u00edstu. Tato zkou\u0161ka ur\u010duje s\u00edlu pot\u0159ebnou k zah\u00e1jen\u00ed a udr\u017een\u00ed pohybu p\u00edstu st\u0159\u00edka\u010dky, co\u017e zaji\u0161\u0165uje konzistentn\u00ed pod\u00e1v\u00e1n\u00ed l\u00e9ku a bezpe\u010dnost pacienta.<\/p>\n\n\n\n<p>Cell Instruments, p\u0159edn\u00ed v\u00fdrobce <strong data-start=\"826\" data-end=\"857\">za\u0159\u00edzen\u00ed pro testov\u00e1n\u00ed materi\u00e1l\u016f<\/strong>, poskytuje pokro\u010dil\u00e9 <strong data-start=\"877\" data-end=\"925\">stroje pro zkou\u0161en\u00ed s\u00edly p\u0159i uvoln\u011bn\u00ed a klouz\u00e1n\u00ed<\/strong> navr\u017een\u00e9 podle <em data-start=\"948\" data-end=\"960\">ISO 7886-1<\/em> normy. Tyto p\u0159\u00edstroje pom\u00e1haj\u00ed v\u00fdrobc\u016fm, laborato\u0159\u00edm a odborn\u00edk\u016fm na kontrolu kvality zajistit, aby jejich st\u0159\u00edka\u010dky spl\u0148ovaly mezin\u00e1rodn\u00ed po\u017eadavky na kvalitu a v\u00fdkon.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">ISO 7886-1 a v\u00fdkon st\u0159\u00edka\u010dky<\/h2>\n\n\n\n<p>Mezin\u00e1rodn\u00ed standard <strong data-start=\"1233\" data-end=\"1247\">ISO 7886-1<\/strong> specifikuje po\u017eadavky a zku\u0161ebn\u00ed metody pro steriln\u00ed injek\u010dn\u00ed st\u0159\u00edka\u010dky pro jedno pou\u017eit\u00ed. P\u0159\u00edloha E normy uv\u00e1d\u00ed <strong data-start=\"1377\" data-end=\"1450\">zku\u0161ebn\u00ed metoda pro stanoven\u00ed sil pot\u0159ebn\u00fdch k ovl\u00e1d\u00e1n\u00ed p\u00edstu<\/strong>, v\u010detn\u011b obou <em data-start=\"1467\" data-end=\"1486\">uvolnit s\u00edlu<\/em> a <em data-start=\"1491\" data-end=\"1506\">klouzav\u00e1 s\u00edla<\/em>.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"1513\" data-end=\"1534\">S\u00edla uvoln\u011bn\u00ed<\/strong> odkazuje na <em data-start=\"1549\" data-end=\"1564\">po\u010d\u00e1te\u010dn\u00ed s\u00edla<\/em> pot\u0159ebn\u00fd k zah\u00e1jen\u00ed pohybu p\u00edstu.<\/li>\n\n\n\n<li><strong data-start=\"1609\" data-end=\"1626\">Kluzn\u00e1 s\u00edla<\/strong> p\u0159edstavuje <em data-start=\"1642\" data-end=\"1660\">nep\u0159etr\u017eit\u00e1 s\u00edla<\/em> pot\u0159ebn\u00e9 k udr\u017een\u00ed pohybu p\u00edstu po celou dobu zdvihu.<\/li>\n<\/ul>\n\n\n\n<p>Tyto dva parametry jsou rozhoduj\u00edc\u00edmi ukazateli kvality injek\u010dn\u00ed st\u0159\u00edka\u010dky a ovliv\u0148uj\u00ed pohodl\u00ed u\u017eivatele, p\u0159esnost vst\u0159ikov\u00e1n\u00ed a stabilitu toku l\u00e9\u010diva. Nadm\u011brn\u00e9 nebo nestejn\u00e9 s\u00edly mohou v\u00e9st k trhav\u00e9mu pohybu, chyb\u00e1m v d\u00e1vkov\u00e1n\u00ed nebo dokonce k selh\u00e1n\u00ed st\u0159\u00edka\u010dky.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Princip zkou\u0161en\u00ed s\u00edly p\u0159i uvoln\u011bn\u00ed a klouz\u00e1n\u00ed<br><small> -- ISO 7886-1 P\u0159\u00edloha E<\/small><\/h2>\n\n\n\n<p>The <strong data-start=\"2029\" data-end=\"2068\">uvoln\u011bte se a testujte klouzavou s\u00edlu<\/strong> proces pou\u017e\u00edv\u00e1 <strong data-start=\"2084\" data-end=\"2114\">mechanick\u00fd zku\u0161ebn\u00ed stroj<\/strong> tla\u010dit na p\u00edst st\u0159\u00edka\u010dky a z\u00e1rove\u0148 m\u011b\u0159it a zaznamen\u00e1vat p\u016fsob\u00edc\u00ed s\u00edlu. Test hodnot\u00ed, jak hladce p\u00edst pracuje za standardizovan\u00fdch podm\u00ednek, jako je teplota a rychlost posunu.<\/p>\n\n\n\n<p>B\u011bhem testu:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Injek\u010dn\u00ed st\u0159\u00edka\u010dka je napln\u011bna vodou udr\u017eovanou na teplot\u011b <em data-start=\"2392\" data-end=\"2404\">(23 \u00b1 5)\u00b0C<\/em>.<\/li>\n\n\n\n<li>Tryska st\u0159\u00edka\u010dky se p\u0159ipojuje k z\u00e1sobn\u00edku vody s kontrolovanou hladinou.<\/li>\n\n\n\n<li>Zku\u0161ebn\u00ed stroj pohybuje p\u00edstem konstantn\u00ed rychlost\u00ed. <em data-start=\"2548\" data-end=\"2568\">(100 \u00b1 5) mm\/min).<\/em><\/li>\n\n\n\n<li>Syst\u00e9m zaznamen\u00e1v\u00e1:\n<ul class=\"wp-block-list\">\n<li>The <strong data-start=\"2605\" data-end=\"2631\">s\u00edla uvoln\u011bn\u00ed (Fs)<\/strong> - s\u00edla pot\u0159ebn\u00e1 k zah\u00e1jen\u00ed pohybu p\u00edstu.<\/li>\n\n\n\n<li>The <strong data-start=\"2686\" data-end=\"2712\">st\u0159edn\u00ed klouzav\u00e1 s\u00edla (F)<\/strong> - pr\u016fm\u011brn\u00e1 s\u00edla p\u0159i rovnom\u011brn\u00e9m pohybu p\u00edstu.<\/li>\n\n\n\n<li>The <strong data-start=\"2772\" data-end=\"2796\">maxim\u00e1ln\u00ed s\u00edla (Fmax)<\/strong> - maxim\u00e1ln\u00ed s\u00edla pozorovan\u00e1 p\u0159i pohybu.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<p>Tyto parametry jsou vykresleny jako <em style=\"font-size: 16px;\" data-start=\"2873\" data-end=\"2899\">k\u0159ivka s\u00edla-posun<\/em>, co\u017e umo\u017e\u0148uje jasnou vizualizaci v\u00fdkonnostn\u00edch charakteristik st\u0159\u00edka\u010dky.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Tester posuvn\u00e9ho odporu st\u0159\u00edka\u010dky SSR-01<\/h2>\n\n\n\n<p>Cell Instruments nab\u00edz\u00ed precizn\u011b navr\u017eenou <strong data-start=\"3081\" data-end=\"3129\">stroje pro zkou\u0161en\u00ed s\u00edly p\u0159i uvoln\u011bn\u00ed a klouz\u00e1n\u00ed<\/strong> kter\u00e9 jsou v souladu s <em data-start=\"3147\" data-end=\"3159\">ISO 7886-1<\/em> a souvisej\u00edc\u00ed normy pro farmaceutick\u00e9 zkou\u0161ky.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Mezi kl\u00ed\u010dov\u00e9 vlastnosti pat\u0159\u00ed:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"3598\" data-end=\"3616\">Vysok\u00e1 p\u0159esnost<\/strong>: P\u0159esnost s\u00edly a\u017e do <strong data-start=\"3639\" data-end=\"3647\">0.5%<\/strong> pln\u00e9ho rozsahu.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3673\" data-end=\"3698\">\u0160irok\u00fd rozsah testovac\u00ed rychlosti<\/strong>: Nastaviteln\u00fd od <strong style=\"font-size: 16px;\" data-start=\"3716\" data-end=\"3735\">1 a\u017e 500 mm\/min<\/strong> p\u0159izp\u016fsobit r\u016fzn\u00fdm zku\u0161ebn\u00edm podm\u00ednk\u00e1m.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3778\" data-end=\"3805\">M\u011b\u0159en\u00ed t\u0159\u00ed sil<\/strong>: Automaticky zaznamen\u00e1v\u00e1 s\u00edlu uvoln\u011bn\u00ed, st\u0159edn\u00ed klouzavou s\u00edlu a maxim\u00e1ln\u00ed s\u00edlu.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3888\" data-end=\"3915\">U\u017eivatelsky p\u0159\u00edv\u011btiv\u00e9 rozhran\u00ed<\/strong>: <strong style=\"font-size: 16px;\" data-start=\"3917\" data-end=\"3935\">\u0158\u00edzen\u00e9 PLC<\/strong> s <strong style=\"font-size: 16px;\" data-start=\"3943\" data-end=\"3969\">7palcov\u00fd dotykov\u00fd displej HMI<\/strong> pro bezprobl\u00e9mov\u00fd provoz.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3996\" data-end=\"4016\">Vestav\u011bn\u00e1 tisk\u00e1rna<\/strong>: Poskytuje okam\u017eit\u00e9 v\u00fdsledky test\u016f pro dokumentaci a zaji\u0161t\u011bn\u00ed kvality.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"4093\" data-end=\"4116\">Ochrana proti p\u0159et\u00ed\u017een\u00ed<\/strong>: Zaji\u0161\u0165uje dlouhodobou \u017eivotnost a bezpe\u010dnost obsluhy.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Hlavn\u00ed parametr<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Sn\u00edma\u010d zat\u00ed\u017een\u00ed<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">200N (nebo podle pot\u0159eby)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Testovac\u00ed rychlost<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">1~500 mm\/min<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>P\u0159esnost<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">0,01 mm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Moc<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">110~220V<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Aplikace a dopad na pr\u016fmysl<\/h2>\n\n\n\n<p>Zkou\u0161ky s\u00edly uvoln\u011bn\u00ed a kluzn\u00e9 s\u00edly jsou kritick\u00e9 v r\u016fzn\u00fdch odv\u011btv\u00edch:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"4294\" data-end=\"4313\">L\u00e9ka\u0159sk\u00e1 za\u0159\u00edzen\u00ed<\/strong>: Zaji\u0161\u0165uje bezpe\u010dnost a pou\u017eitelnost st\u0159\u00edka\u010dek pro zdravotn\u00edky a pacienty.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"4397\" data-end=\"4416\">L\u00e9\u010diva<\/strong>: Ov\u011b\u0159uje konzistenci v\u00fdrobku p\u0159ed distribuc\u00ed.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"4470\" data-end=\"4492\">Regula\u010dn\u00ed testov\u00e1n\u00ed<\/strong>: Poskytuje \u00fadaje nezbytn\u00e9 pro dodr\u017eov\u00e1n\u00ed <strong style=\"font-size: 16px;\" data-start=\"4538\" data-end=\"4560\"><a href=\"https:\/\/www.iso.org\/standard\/64790.html\" target=\"_blank\" rel=\"noopener nofollow\">ISO 7886-1<\/a> testov\u00e1n\u00ed<\/strong> po\u017eadavky.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"4577\" data-end=\"4596\">Kontrola kvality<\/strong>: Pom\u00e1h\u00e1 v\u00fdrobc\u016fm udr\u017eovat vysok\u00e9 v\u00fdrobn\u00ed standardy a sni\u017eovat m\u00edru vad.<\/li>\n<\/ul>\n\n\n\n<p>D\u00edky sv\u00e9 p\u0159esnosti a dodr\u017eov\u00e1n\u00ed protokol\u016f ISO je SSR-01 ide\u00e1ln\u00ed pro. <strong data-start=\"4759\" data-end=\"4810\">v\u00fdrobci injek\u010dn\u00edch st\u0159\u00edka\u010dek, farmaceutick\u00e9 spole\u010dnosti<\/strong>a <strong data-start=\"4816\" data-end=\"4847\">agentury pro kontrolu kvality<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pro\u010d zvolit Cell Instruments?<\/h2>\n\n\n\n<p>Jako zku\u0161en\u00fd v\u00fdrobce specializuj\u00edc\u00ed se na <strong data-start=\"4456\" data-end=\"4491\">testov\u00e1n\u00ed a automatizace materi\u00e1l\u016f<\/strong>, Cell Instruments poskytuje kompletn\u00ed \u0159e\u0161en\u00ed pro <strong data-start=\"4542\" data-end=\"4589\">testov\u00e1n\u00ed uvoln\u011bn\u00ed st\u0159\u00edka\u010dky a kluzn\u00e9 s\u00edly<\/strong>. Kombinujeme vysoce p\u0159esn\u00e9 in\u017een\u00fdrstv\u00ed, p\u0159izp\u016fsobiteln\u00fd software a odbornou technickou podporu, abychom klient\u016fm pomohli splnit p\u0159\u00edsn\u00e9 pr\u016fmyslov\u00e9 normy.<\/p>\n\n\n\n<p><strong data-start=\"4962\" data-end=\"5001\">Uvoln\u011bn\u00ed a testov\u00e1n\u00ed s\u00edly klouz\u00e1n\u00ed<\/strong> je nezbytnou sou\u010d\u00e1st\u00ed ov\u011b\u0159ov\u00e1n\u00ed kvality injek\u010dn\u00edch st\u0159\u00edka\u010dek podle <em data-start=\"5068\" data-end=\"5080\">ISO 7886-1<\/em>. M\u00e1 p\u0159\u00edm\u00fd vliv na pou\u017eitelnost, bezpe\u010dnost a dodr\u017eov\u00e1n\u00ed p\u0159edpis\u016f. Pomoc\u00ed profesion\u00e1ln\u00edch testovac\u00edch n\u00e1stroj\u016f od <strong data-start=\"5195\" data-end=\"5215\">Bun\u011b\u010dn\u00e9 n\u00e1stroje<\/strong>, mohou laborato\u0159e a v\u00fdrobci dos\u00e1hnout spolehliv\u00fdch, p\u0159esn\u00fdch a reprodukovateln\u00fdch v\u00fdsledk\u016f - co\u017e zvy\u0161uje v\u00fdkonnost v\u00fdrobk\u016f i d\u016fv\u011bru z\u00e1kazn\u00edk\u016f.<\/p>","protected":false},"excerpt":{"rendered":"<p>Break loose and glide force testing measure the force required to initiate and maintain the motion of the syringe piston.<\/p>","protected":false},"featured_media":5356,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"product-category":[454,438,495,593],"product-tag":[],"class_list":["post-9585","products","type-products","status-publish","has-post-thumbnail","hentry","product-category-custom-lab-testing-instruments-manufacturer","product-category-medical-and-pharmaceutical-testing","product-category-pharmaceutical-testing","product-category-syringe-testing"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/cs\/wp-json\/wp\/v2\/products\/9585","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/cs\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.packqc.com\/cs\/wp-json\/wp\/v2\/types\/products"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/cs\/wp-json\/wp\/v2\/media\/5356"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/cs\/wp-json\/wp\/v2\/media?parent=9585"}],"wp:term":[{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/www.packqc.com\/cs\/wp-json\/wp\/v2\/product-category?post=9585"},{"taxonomy":"product-tag","embeddable":true,"href":"https:\/\/www.packqc.com\/cs\/wp-json\/wp\/v2\/product-tag?post=9585"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}