{"id":9861,"date":"2026-02-24T15:11:46","date_gmt":"2026-02-24T07:11:46","guid":{"rendered":"https:\/\/www.packqc.com\/standard\/iso-7886-1-2\/"},"modified":"2026-04-16T09:54:22","modified_gmt":"2026-04-16T01:54:22","slug":"iso-7886-1","status":"publish","type":"standard","link":"https:\/\/www.packqc.com\/cs\/standard\/iso-7886-1\/","title":{"rendered":"ISO 7886-1"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Porozum\u011bn\u00ed norm\u011b ISO 7886-1<\/h2>\n\n\n\n<p>The <strong data-start=\"1069\" data-end=\"1083\">ISO 7886-1<\/strong> norma specifikuje konstruk\u010dn\u00ed, v\u00fdkonnostn\u00ed a zku\u0161ebn\u00ed krit\u00e9ria pro injek\u010dn\u00ed st\u0159\u00edka\u010dky na jedno pou\u017eit\u00ed pou\u017e\u00edvan\u00e9 ve zdravotnictv\u00ed a laborato\u0159\u00edch. Zaji\u0161\u0165uje, aby st\u0159\u00edka\u010dky zachov\u00e1valy integritu za mechanick\u00fdch a tlakov\u00fdch podm\u00ednek a za podm\u00ednek net\u011bsnosti.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Zji\u0161\u0165ov\u00e1n\u00ed net\u011bsnost\u00ed injek\u010dn\u00edch st\u0159\u00edka\u010dek - test \u00faniku vzduchu a kapaliny<\/h2>\n\n\n\n<p>Zji\u0161\u0165ov\u00e1n\u00ed net\u011bsnost\u00ed je jednou z nejd\u016fle\u017eit\u011bj\u0161\u00edch zkou\u0161ek uveden\u00fdch v r\u00e1mci normy <strong data-start=\"2024\" data-end=\"2041\">P\u0159\u00edloha B a D<\/strong> ISO 7886-1. Ur\u010duje, zda za ur\u010dit\u00fdch tlakov\u00fdch podm\u00ednek doch\u00e1z\u00ed k \u00fanik\u016fm vzduchu nebo kapaliny kolem z\u00e1tky p\u00edstu nebo v\u00e1lce.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">P\u0159\u00edloha B - Zkou\u0161ka t\u011bsnosti vzduchu<\/h3>\n\n\n\n<p><strong data-start=\"2179\" data-end=\"2209\">Zkou\u0161ka t\u011bsnosti (p\u0159\u00edloha B)<\/strong> vy\u017eaduje, aby byla st\u0159\u00edka\u010dka \u010d\u00e1ste\u010dn\u011b napln\u011bna vodou a vystavena vakuu o velikosti <strong data-start=\"2294\" data-end=\"2327\">88 kPa pod okoln\u00edm tlakem<\/strong>. Jak\u00e9koli viditeln\u00e9 vzduchov\u00e9 bubliny nebo pokles tlaku ukazuj\u00ed na net\u011bsnost nebo \u0161patn\u00e9 ut\u011bsn\u011bn\u00ed. <strong data-start=\"2405\" data-end=\"2452\">Cell Instruments SLT-02 Tester t\u011bsnosti st\u0159\u00edka\u010dek<\/strong> dokonale simuluje tento proces a umo\u017e\u0148uje obsluze aplikovat \u0159\u00edzen\u00fd podtlak a p\u0159esn\u011b sledovat \u00faniky.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">P\u0159\u00edloha D - Zkou\u0161ka t\u011bsnosti kapalin<\/h3>\n\n\n\n<p><strong data-start=\"2577\" data-end=\"2613\">Zkou\u0161ka t\u011bsnosti (p\u0159\u00edloha D)<\/strong> hodnot\u00ed t\u011bsnost st\u0159\u00edka\u010dky p\u0159i vnit\u0159n\u00edm stla\u010den\u00ed. Pomoc\u00ed za\u0159\u00edzen\u00ed, jako je nap\u0159. <strong data-start=\"2702\" data-end=\"2763\">Cell Instruments SPPT-01 Tester pozitivn\u00edho tlaku ve st\u0159\u00edka\u010dce<\/strong>, st\u0159\u00edka\u010dka se napln\u00ed, ut\u011bsn\u00ed a natlakuje a\u017e na \u00farove\u0148 <strong data-start=\"2818\" data-end=\"2829\">300 kPa<\/strong>, kter\u00e9 kop\u00edruj\u00ed podm\u00ednky re\u00e1ln\u00e9ho pou\u017eit\u00ed. Pozorov\u00e1n\u00ed prosakov\u00e1n\u00ed vody identifikuje mo\u017en\u00e9 v\u00fdrobn\u00ed vady.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">P\u0159\u00edloha E<small>-- testov\u00e1n\u00ed s\u00edly klouz\u00e1n\u00ed st\u0159\u00edka\u010dky a testov\u00e1n\u00ed s\u00edly p\u0159i uvoln\u011bn\u00ed st\u0159\u00edka\u010dky<\/small><\/h3>\n\n\n\n<p>Hladk\u00fd chod p\u00edstu st\u0159\u00edka\u010dky je nezbytn\u00fd pro p\u0159esn\u00e9 pod\u00e1n\u00ed l\u00e9ku a pohodl\u00ed pacienta. <strong data-start=\"3249\" data-end=\"3260\">P\u0159\u00edloha E<\/strong> normy ISO 7886-1 definuje postupy pro m\u011b\u0159en\u00ed <strong data-start=\"3312\" data-end=\"3354\">s\u00edly pot\u0159ebn\u00e9 k ovl\u00e1d\u00e1n\u00ed p\u00edstu<\/strong>-v\u010detn\u011b <em data-start=\"3365\" data-end=\"3384\">uvolnit s\u00edlu<\/em> (po\u010d\u00e1te\u010dn\u00ed pohyb) a <em data-start=\"3408\" data-end=\"3421\">klouzav\u00e1 s\u00edla<\/em> (rovnom\u011brn\u00fd pohyb).<\/p>\n\n\n\n<p>Pomoc\u00ed a <strong data-start=\"3448\" data-end=\"3478\">mechanick\u00fd zku\u0161ebn\u00ed stroj<\/strong>, p\u00edst se pohybuje \u0159\u00edzenou rychlost\u00ed v rozmez\u00ed <strong data-start=\"3526\" data-end=\"3544\">100 \u00b1 5 mm\/min<\/strong>, p\u0159i\u010dem\u017e hodnoty s\u00edly jsou pr\u016fb\u011b\u017en\u011b zaznamen\u00e1v\u00e1ny. Nadm\u011brn\u00e1 nebo nekonzistentn\u00ed s\u00edla m\u016f\u017ee indikovat \u0161patn\u00e9 maz\u00e1n\u00ed, nekompatibilitu materi\u00e1lu nebo deformaci hlavn\u011b.<\/p>\n\n\n\n<p>The <strong data-start=\"3709\" data-end=\"3763\">Cell Instruments SSR-01 Tester kluzn\u00e9 s\u00edly st\u0159\u00edka\u010dky<\/strong> umo\u017e\u0148uje p\u0159esn\u00e9 ur\u010den\u00ed:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"3801\" data-end=\"3828\">S\u00edla uvoln\u011bn\u00ed (fs):<\/strong> S\u00edla pot\u0159ebn\u00e1 k zah\u00e1jen\u00ed pohybu p\u00edstu<\/li>\n\n\n\n<li><strong data-start=\"3872\" data-end=\"3902\">Trval\u00e1 klouzavost (F):<\/strong> Pr\u016fm\u011brn\u00e1 s\u00edla p\u0159i pohybu p\u00edstu<\/li>\n\n\n\n<li><strong data-start=\"3943\" data-end=\"3974\">Maxim\u00e1ln\u00ed klouzav\u00e1 s\u00edla (Fmax):<\/strong> Pozorovan\u00e1 maxim\u00e1ln\u00ed odporov\u00e1 s\u00edla<\/li>\n<\/ul>\n\n\n\n<p>Tyto \u00fadaje zaji\u0161\u0165uj\u00ed, \u017ee st\u0159\u00edka\u010dky poskytuj\u00ed konzistentn\u00ed v\u00fdkon a spl\u0148uj\u00ed ergonomick\u00e9 po\u017eadavky definovan\u00e9 v norm\u011b ISO 7886-1.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Testov\u00e1n\u00ed podko\u017en\u00edch st\u0159\u00edka\u010dek a kompatibility jehel<\/h2>\n\n\n\n<p>Krom\u011b hodnocen\u00ed v\u00e1lce st\u0159\u00edka\u010dky a p\u00edstu, <strong data-start=\"4236\" data-end=\"4250\">ISO 7886-1<\/strong> pracuje ve spojen\u00ed s <strong data-start=\"4277\" data-end=\"4289\">ISO 7864<\/strong>, kter\u00e1 se \u0159\u00edd\u00ed <em data-start=\"4305\" data-end=\"4348\">steriln\u00ed podko\u017en\u00ed jehly na jedno pou\u017eit\u00ed<\/em>. Spr\u00e1vn\u00e9 spojen\u00ed mezi st\u0159\u00edka\u010dkou a jehlou se ov\u011b\u0159uje pomoc\u00ed ku\u017eelov\u00e9ho \u0161rouben\u00ed, kter\u00e9 je v souladu s normou. <strong data-start=\"4445\" data-end=\"4460\">ISO 80369-7<\/strong>. Testov\u00e1n\u00ed kompatibility zaji\u0161\u0165uje bezpe\u010dn\u00e9 uchycen\u00ed a zabra\u0148uje \u00faniku tekutin p\u0159i p\u0159enosu. Tento aspekt je z\u00e1sadn\u00ed p\u0159i <a href=\"https:\/\/www.packqc.com\/cs\/solutions\/syringe-testing\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"4572\" data-end=\"4602\">testov\u00e1n\u00ed podko\u017en\u00edch st\u0159\u00edka\u010dek<\/strong><\/a> kde je p\u0159esn\u00e9 vst\u0159ikov\u00e1n\u00ed v l\u00e9ka\u0159sk\u00e9m a farmaceutick\u00e9m pr\u016fmyslu povinn\u00e9.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Za\u0159\u00edzen\u00ed pro testov\u00e1n\u00ed st\u0159\u00edka\u010dek od Cell Instruments<\/h2>\n\n\n\n<p><strong data-start=\"4752\" data-end=\"4782\">Spole\u010dnost Cell Instruments Co., Ltd.<\/strong> poskytuje komplexn\u00ed \u0159e\u0161en\u00ed pro testov\u00e1n\u00ed injek\u010dn\u00edch st\u0159\u00edka\u010dek pln\u011b v souladu s po\u017eadavky normy ISO 7886-1:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"4879\" data-end=\"4910\"><a href=\"https:\/\/www.packqc.com\/cs\/product\/syringe-leak-testing-machine\/\" target=\"_blank\" rel=\"noopener\">SLT-02 Tester t\u011bsnosti st\u0159\u00edka\u010dek<\/a>:<\/strong> Prov\u00e1d\u00ed p\u0159esnou detekci \u00faniku vzduchu na z\u00e1klad\u011b vakua.<\/li>\n\n\n\n<li><strong data-start=\"4968\" data-end=\"5013\"><a href=\"https:\/\/www.packqc.com\/cs\/product\/syringe-liquid-leak-tester-iso-7886-1\/\" target=\"_blank\" rel=\"noopener\">SPPT-01 Tester pozitivn\u00edho tlaku ve st\u0159\u00edka\u010dce<\/a>:<\/strong> Vyhodnocuje t\u011bsn\u011bn\u00ed p\u00edstov\u00e9 z\u00e1tky p\u0159i stla\u010den\u00ed a odolnost proti \u00faniku kapaliny.<\/li>\n\n\n\n<li><strong data-start=\"5101\" data-end=\"5139\"><a href=\"https:\/\/www.packqc.com\/cs\/product\/break-loose-force-and-glide-force-tester\/\" target=\"_blank\" rel=\"noopener\">SSR-01 Tester kluzn\u00e9 s\u00edly st\u0159\u00edka\u010dky<\/a>:<\/strong> S vysokou p\u0159esnost\u00ed ur\u010duje s\u00edly uvoln\u011bn\u00ed a klouz\u00e1n\u00ed pro ov\u011b\u0159en\u00ed v\u00fdkonu.<\/li>\n<\/ul>\n\n\n\n<p>Ka\u017ed\u00fd p\u0159\u00edstroj je navr\u017een s pokro\u010dilou automatizac\u00ed a digit\u00e1ln\u00edm sb\u011brem dat, co\u017e zaji\u0161\u0165uje p\u0159esn\u00e9 a opakovateln\u00e9 v\u00fdsledky a z\u00e1rove\u0148 zjednodu\u0161uje pracovn\u00ed postupy kontroly kvality. D\u00edky vlastn\u00ed automatizaci testov\u00e1n\u00ed a funkc\u00edm z\u00e1znamu dat jsou tyto p\u0159\u00edstroje vhodn\u00e9 pro v\u00fdrobce zdravotnick\u00fdch prost\u0159edk\u016f, laborato\u0159e a odd\u011blen\u00ed kontroly kvality.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Kontaktujte n\u00e1s Z\u00edskejte \u0159e\u0161en\u00ed pro testov\u00e1n\u00ed ISO 7886-1 <\/h2>\n\n\n\n<p>Soulad s <a href=\"https:\/\/www.iso.org\/standard\/64790.html\" target=\"_blank\" rel=\"noopener nofollow\"><strong data-start=\"5609\" data-end=\"5623\">ISO 7886-1<\/strong><\/a> je z\u00e1sadn\u00ed pro v\u00fdrobce, kte\u0159\u00ed cht\u011bj\u00ed vyr\u00e1b\u011bt bezpe\u010dn\u00e9, \u00fa\u010dinn\u00e9 a spolehliv\u00e9 v\u00fdrobky. <strong data-start=\"5703\" data-end=\"5734\">steriln\u00ed injek\u010dn\u00ed st\u0159\u00edka\u010dky<\/strong>. Integrac\u00ed standardizovan\u00fdch testovac\u00edch metod - jako nap\u0159. <strong data-start=\"5788\" data-end=\"5819\">detekce net\u011bsnost\u00ed v injek\u010dn\u00edch st\u0159\u00edka\u010dk\u00e1ch<\/strong>, <strong data-start=\"5821\" data-end=\"5852\">testov\u00e1n\u00ed s\u00edly skluzu injek\u010dn\u00ed st\u0159\u00edka\u010dky<\/strong>a <strong data-start=\"5858\" data-end=\"5893\">testov\u00e1n\u00ed kluzn\u00e9 s\u00edly p\u0159i uvoln\u011bn\u00ed<\/strong>-t\u00fdmy pro zaji\u0161t\u011bn\u00ed kvality mohou ov\u011b\u0159it integritu produktu a konzistenci v\u00fdkonu.<\/p>","protected":false},"excerpt":{"rendered":"<p>Porozum\u011bn\u00ed norm\u011b ISO 7886-1 Norma ISO 7886-1 specifikuje krit\u00e9ria pro konstrukci, proveden\u00ed a zkou\u0161en\u00ed injek\u010dn\u00edch st\u0159\u00edka\u010dek na jedno pou\u017eit\u00ed pou\u017e\u00edvan\u00fdch ve zdravotnictv\u00ed a laborato\u0159\u00edch. Zaji\u0161\u0165uje, aby st\u0159\u00edka\u010dky zachov\u00e1valy integritu za mechanick\u00fdch a tlakov\u00fdch podm\u00ednek a za podm\u00ednek net\u011bsnosti. Detekce net\u011bsnost\u00ed injek\u010dn\u00edch st\u0159\u00edka\u010dek - zkou\u0161ka t\u011bsnosti vzduchu a kapaliny Detekce net\u011bsnost\u00ed je jednou z nejd\u016fle\u017eit\u011bj\u0161\u00edch zkou\u0161ek specifikovan\u00fdch v [...]<\/p>","protected":false},"featured_media":8033,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"standard-category":[612],"class_list":["post-9861","standard","type-standard","status-publish","has-post-thumbnail","hentry","standard-category-iso"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/cs\/wp-json\/wp\/v2\/standard\/9861","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/cs\/wp-json\/wp\/v2\/standard"}],"about":[{"href":"https:\/\/www.packqc.com\/cs\/wp-json\/wp\/v2\/types\/standard"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/cs\/wp-json\/wp\/v2\/media\/8033"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/cs\/wp-json\/wp\/v2\/media?parent=9861"}],"wp:term":[{"taxonomy":"standard-category","embeddable":true,"href":"https:\/\/www.packqc.com\/cs\/wp-json\/wp\/v2\/standard-category?post=9861"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}