{"id":6992,"date":"2025-07-22T15:11:56","date_gmt":"2025-07-22T07:11:56","guid":{"rendered":"https:\/\/www.packqc.com\/?p=6992"},"modified":"2025-09-12T08:34:06","modified_gmt":"2025-09-12T00:34:06","slug":"iso-9187-1","status":"publish","type":"post","link":"https:\/\/www.packqc.com\/de\/iso-9187-1\/","title":{"rendered":"ISO 9187 Konformit\u00e4t und Bruchkraftmessung f\u00fcr Glasampullen"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6992\" class=\"elementor elementor-6992\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9ef650f e-flex e-con-boxed e-con e-parent\" data-id=\"9ef650f\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2b878ea elementor-widget elementor-widget-theme-post-title elementor-page-title elementor-widget-heading\" data-id=\"2b878ea\" data-element_type=\"widget\" data-widget_type=\"theme-post-title.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 9187 Konformit\u00e4t und Bruchkraftmessung f\u00fcr Glasampullen<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9e32292 elementor-widget elementor-widget-heading\" data-id=\"9e32292\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Einf\u00fchrung in die ISO 9187-1 f\u00fcr Ampullen<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-31d2386 e-flex e-con-boxed e-con e-parent\" data-id=\"31d2386\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a1a4f81 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"a1a4f81\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"492\" data-end=\"1014\">ISO 9187 ist eine wichtige internationale Norm, die die technischen und leistungsbezogenen Anforderungen an Glasampullen f\u00fcr medizinische Injektionsg\u00fcter festlegt. Die Norm gew\u00e4hrleistet, dass Ampullen sicher und zuverl\u00e4ssig sind und sich f\u00fcr die Aufbewahrung steriler pharmazeutischer Produkte eignen. Sie gilt in erster Linie f\u00fcr Ampullen aus Glas und konzentriert sich auf Schl\u00fcsseleigenschaften wie <strong data-start=\"889\" data-end=\"914\">hydrolytische Best\u00e4ndigkeit<\/strong>, <strong data-start=\"916\" data-end=\"937\">Gl\u00fchqualit\u00e4t<\/strong>, und die <strong data-start=\"947\" data-end=\"965\">Bruchkraft<\/strong> erforderlich, um die Ampulle sauber und sicher zu \u00f6ffnen.<\/p><p data-start=\"1016\" data-end=\"1314\">In der Medizin und Pharmazie m\u00fcssen Ampullen steril bleiben und gleichzeitig leicht zu \u00f6ffnen sein, ohne dass es zu Glasscherben oder Verletzungen des Benutzers kommt. Daher ist eine genaue <strong data-start=\"1175\" data-end=\"1224\">Bruchkraftmessung f\u00fcr Glasampullen<\/strong> wesentlich ist, und <a href=\"https:\/\/www.iso.org\/standard\/55920.html\" target=\"_blank\" rel=\"noopener nofollow\">ISO 9187-1<\/a> liefert die genauen Pr\u00fcfprotokolle zur Bewertung dieser Eigenschaft.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8349dad elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"8349dad\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.packqc.com\/de\/product\/bst-01-glass-ampoule-break-force-tester\/\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1011\" height=\"662\" src=\"https:\/\/www.packqc.com\/wp-content\/uploads\/2025\/07\/ampoule-breaking-tester.webp\" class=\"attachment-large size-large wp-image-7003\" alt=\"iso 9187-1\" srcset=\"https:\/\/www.packqc.com\/wp-content\/uploads\/2025\/07\/ampoule-breaking-tester.webp 1011w, https:\/\/www.packqc.com\/wp-content\/uploads\/2025\/07\/ampoule-breaking-tester-600x393.webp 600w, https:\/\/www.packqc.com\/wp-content\/uploads\/2025\/07\/ampoule-breaking-tester-300x196.webp 300w, https:\/\/www.packqc.com\/wp-content\/uploads\/2025\/07\/ampoule-breaking-tester-768x503.webp 768w, https:\/\/www.packqc.com\/wp-content\/uploads\/2025\/07\/ampoule-breaking-tester-18x12.webp 18w\" sizes=\"(max-width: 1011px) 100vw, 1011px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3ffff35 e-flex e-con-boxed e-con e-parent\" data-id=\"3ffff35\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6cb9a7e elementor-widget elementor-widget-heading\" data-id=\"6cb9a7e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Bruchkraftmessung f\u00fcr Glasampullen und die Rolle der ISO 9187-1<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5809b79 e-flex e-con-boxed e-con e-parent\" data-id=\"5809b79\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4a1c345 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"4a1c345\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1401\" data-end=\"1641\">Der <strong data-start=\"1405\" data-end=\"1441\">Ampullenbruchpr\u00fcfung ISO 9187-1<\/strong> definiert ein standardisiertes Verfahren zur Bestimmung der Bruchkraft von Ampullen. Dadurch wird sichergestellt, dass sie an einer bestimmten Stelle, die in der Regel durch einen Keramikring oder ein Farbpigment gekennzeichnet ist, vorhersehbar brechen.<\/p><p data-start=\"1643\" data-end=\"1815\">Nach Angaben von <strong data-start=\"1656\" data-end=\"1675\">ISO 9187-1:2010<\/strong>, Die Bruchkraftpr\u00fcfung muss mit einer Zugpr\u00fcfmaschine durchgef\u00fchrt werden, die der Norm ISO 7500-1 entspricht. Zu den wichtigsten Spezifikationen des Ger\u00e4ts geh\u00f6ren:<\/p><ul><li data-start=\"1819\" data-end=\"1846\"><strong data-start=\"1819\" data-end=\"1833\">Testgeschwindigkeit<\/strong>: 10 mm\/min<\/li><li data-start=\"1849\" data-end=\"1883\"><strong data-start=\"1849\" data-end=\"1874\">Kraftmessbereich<\/strong>: 200 N<\/li><li data-start=\"1886\" data-end=\"1922\"><strong data-start=\"1886\" data-end=\"1909\">Konditionierung von Proben<\/strong>: 20 \u00b1 5 \u00b0C<\/li><li data-start=\"1925\" data-end=\"1977\"><strong data-start=\"1925\" data-end=\"1942\">Probenahmeplan<\/strong>: Zuf\u00e4llig, gem\u00e4\u00df ISO 2859-1, Stufe S-4<\/li><\/ul><p data-start=\"1979\" data-end=\"2298\">Die Ampulle wird so positioniert, dass die Kraft senkrecht auf die Bruchstelle einwirkt. Ein sauberer Bruch mit einer Kraft innerhalb der festgelegten Grenzen (gem\u00e4\u00df Tabelle 2 der Norm) ist erforderlich, um die Anforderungen zu erf\u00fcllen. Abweichungen im Winkel oder in der Position k\u00f6nnen die Bruchkraft drastisch erh\u00f6hen, was auf eine unsachgem\u00e4\u00dfe Konstruktion oder Herstellung der Ampulle hinweist.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f2ca4ec elementor-widget__width-initial elementor-widget elementor-widget-video\" data-id=\"f2ca4ec\" data-element_type=\"widget\" data-settings=\"{&quot;youtube_url&quot;:&quot;https:\\\/\\\/youtu.be\\\/fL78KBZwj3g?si=KFNn9WLEJvHr9UsM&quot;,&quot;autoplay&quot;:&quot;yes&quot;,&quot;play_on_mobile&quot;:&quot;yes&quot;,&quot;mute&quot;:&quot;yes&quot;,&quot;loop&quot;:&quot;yes&quot;,&quot;video_type&quot;:&quot;youtube&quot;,&quot;controls&quot;:&quot;yes&quot;}\" data-widget_type=\"video.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-wrapper elementor-open-inline\">\n\t\t\t<div class=\"elementor-video\"><\/div>\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6dd566f e-flex e-con-boxed e-con e-parent\" data-id=\"6dd566f\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6c111e9 elementor-widget elementor-widget-heading\" data-id=\"6c111e9\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Grundlegende Pr\u00fcfanforderungen nach ISO 9187-1<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-72030ce e-flex e-con-boxed e-con e-parent\" data-id=\"72030ce\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0ad38e2 elementor-widget elementor-widget-text-editor\" data-id=\"0ad38e2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2353\" data-end=\"2461\">Um zu gew\u00e4hrleisten, dass die Ampullen sowohl benutzersicher als auch herstellungskonform sind, legt die ISO 9187-1 die folgenden Ma\u00dfst\u00e4be fest:<\/p><ol><li data-start=\"2466\" data-end=\"2622\"><strong data-start=\"2466\" data-end=\"2491\">Hydrolytische Resistenz<\/strong><br data-start=\"2491\" data-end=\"2494\" \/>Muss konform sein mit <strong data-start=\"2513\" data-end=\"2527\">ISO 4802-1<\/strong> Und <strong data-start=\"2532\" data-end=\"2546\">ISO 4802-2<\/strong>, Sie stellen sicher, dass das Glas nicht durch Wassereinwirkung oder Sterilisation besch\u00e4digt wird.<\/li><li data-start=\"2627\" data-end=\"2810\"><strong data-start=\"2627\" data-end=\"2648\">Qualit\u00e4t des Gl\u00fchens<\/strong><br data-start=\"2648\" data-end=\"2651\" \/>Die Eigenspannung nach dem Gl\u00fchen darf folgende Werte nicht \u00fcberschreiten <strong data-start=\"2702\" data-end=\"2726\">50 nm pro Millimeter<\/strong> der Glasdicke. Unsachgem\u00e4\u00dfes Gl\u00fchen kann zu Mikrorissen oder pl\u00f6tzlichem Bruch f\u00fchren.<\/li><li data-start=\"2815\" data-end=\"2989\"><strong data-start=\"2815\" data-end=\"2833\">Brechende Kraft<\/strong><br data-start=\"2833\" data-end=\"2836\" \/>Gemessen unter kontrollierten mechanischen Bedingungen. Der Bruch sollte sauber an der vorgesehenen Stelle mit minimalen R\u00fcckst\u00e4nden und ohne Glassplitterung erfolgen.<\/li><li data-start=\"2994\" data-end=\"3214\"><strong data-start=\"2994\" data-end=\"3055\">Lage und Stabilit\u00e4t des Bruchpunktes (nach ISO 9187-2)<\/strong><br data-start=\"3055\" data-end=\"3058\" \/>Die Bruchstelle muss mittig ausgerichtet sein (\u00b11 mm Abweichung) und Sterilisation, Reinigung und Temperaturschocks ohne Verschiebung oder Beeintr\u00e4chtigung standhalten.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c9ae016 e-flex e-con-boxed e-con e-parent\" data-id=\"c9ae016\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0fe0339 elementor-widget elementor-widget-heading\" data-id=\"0fe0339\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Warum eine genaue Bruchkraftpr\u00fcfung wichtig ist<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-bef302f e-flex e-con-boxed e-con e-parent\" data-id=\"bef302f\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-885df47 elementor-widget elementor-widget-text-editor\" data-id=\"885df47\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3272\" data-end=\"3463\">Genaue <strong data-start=\"3281\" data-end=\"3330\">Bruchkraftmessung f\u00fcr Glasampullen<\/strong> ist entscheidend f\u00fcr die Sicherheit der Patienten, die Produktintegrit\u00e4t und die Einhaltung gesetzlicher Vorschriften. Eine Ampulle, die unvorhersehbar zerbricht, kann dazu f\u00fchren:<\/p><ul><li data-start=\"3467\" data-end=\"3508\">Verunreinigung des injizierbaren Produkts<\/li><li data-start=\"3511\" data-end=\"3547\">Sch\u00e4digung von Angeh\u00f6rigen der Gesundheitsberufe<\/li><li data-start=\"3550\" data-end=\"3590\">Zur\u00fcckweisung ganzer Produktionschargen<\/li><li data-start=\"3593\" data-end=\"3641\">Nichteinhaltung der internationalen Qualit\u00e4tsaudits<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4c71e50 e-flex e-con-boxed e-con e-parent\" data-id=\"4c71e50\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b91c9d2 elementor-widget elementor-widget-heading\" data-id=\"b91c9d2\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Empfohlene L\u00f6sung: BST-01 Ampullen-Bruchtestger\u00e4t von Cell Instruments<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b2a4e64 e-flex e-con-boxed e-con e-parent\" data-id=\"b2a4e64\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f62dde6 elementor-widget elementor-widget-text-editor\" data-id=\"f62dde6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3728\" data-end=\"3988\">F\u00fcr pharmazeutische Hersteller, Qualit\u00e4tskontrolllabore und Aufsichtsbeh\u00f6rden, die eine zuverl\u00e4ssige Einhaltung von <strong data-start=\"3850\" data-end=\"3862\">ISO 9187<\/strong>die <strong data-start=\"3868\" data-end=\"3902\">BST-01 Ampullen-Bruchtestger\u00e4t<\/strong> von <a href=\"https:\/\/www.packqc.com\/de\/\"><em data-start=\"3906\" data-end=\"3924\">Zellinstrumente<\/em><\/a> bietet eine robuste, hochpr\u00e4zise L\u00f6sung. Dieses fortschrittliche System:<\/p><ul><li data-start=\"3992\" data-end=\"4056\">Entspricht vollst\u00e4ndig der Pr\u00fcfmethodik f\u00fcr die Bruchkraft nach ISO 9187-1<\/li><li data-start=\"4059\" data-end=\"4121\">Erm\u00f6glicht genaue Kraftmessungen mit hoher Wiederholbarkeit<\/li><li data-start=\"4124\" data-end=\"4192\">Unterst\u00fctzt programmierbare Testparameter und automatische Datenaufzeichnung<\/li><li data-start=\"4195\" data-end=\"4264\">Einfaches Laden und Ausrichten der Proben zur Minimierung von Bedienerfehlern<\/li><\/ul><p data-start=\"4266\" data-end=\"4389\">Indem Sie das BST-01 in Ihren QC-Workflow integrieren, stellen Sie sicher, dass jede Ampulle den internationalen Sicherheits- und Qualit\u00e4tsstandards entspricht.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7f23198 e-flex e-con-boxed e-con e-parent\" data-id=\"7f23198\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ac4a46d elementor-widget elementor-widget-heading\" data-id=\"ac4a46d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Schlussfolgerung: Gew\u00e4hrleistung von Konformit\u00e4t und Sicherheit durch ISO 9187-1-Tests<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c52c1ab e-flex e-con-boxed e-con e-parent\" data-id=\"c52c1ab\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ab39cb6 elementor-widget elementor-widget-text-editor\" data-id=\"ab39cb6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4471\" data-end=\"4881\">Einhaltung von <strong data-start=\"4483\" data-end=\"4495\">ISO 9187-1 <\/strong>geht es nicht nur um die Einhaltung gesetzlicher Vorschriften, sondern auch um den Schutz der Patientensicherheit und der Markenintegrit\u00e4t. Mit pr\u00e4zisen <strong data-start=\"4617\" data-end=\"4653\">Ampullenbruchpr\u00fcfung ISO 9187-1<\/strong> Verfahren k\u00f6nnen die Hersteller eine gleichbleibende Produktqualit\u00e4t garantieren. Die Website <a href=\"https:\/\/www.packqc.com\/de\/product\/bst-01-glass-ampoule-break-force-tester\/\"><strong data-start=\"4726\" data-end=\"4760\">BST-01 Ampullen-Bruchtestger\u00e4t<\/strong><\/a> von Cell Instruments bietet die Sicherheit und die technischen M\u00f6glichkeiten, die f\u00fcr genaue und effiziente Konformit\u00e4tspr\u00fcfungen erforderlich sind.<\/p><p data-start=\"4883\" data-end=\"5026\">Um in der pharmazeutischen Qualit\u00e4tskontrolle die Nase vorn zu haben, ist es wichtig, die richtigen Instrumente zu w\u00e4hlen und Standards wie <strong data-start=\"5000\" data-end=\"5012\">ISO 9187<\/strong>-ist unerl\u00e4sslich.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Einf\u00fchrung in die ISO 9187-1 f\u00fcr Ampullen Die ISO 9187 ist eine wichtige internationale Norm, die die technischen und Leistungsanforderungen f\u00fcr Glasampullen f\u00fcr medizinische Injektionszwecke festlegt. Die Norm gew\u00e4hrleistet, dass Ampullen sicher und zuverl\u00e4ssig sind und sich f\u00fcr die Aufbewahrung steriler pharmazeutischer Produkte eignen. Sie gilt in erster Linie f\u00fcr Ampullen aus Glas und konzentriert sich auf die wichtigsten Eigenschaften [...]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-6992","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/de\/wp-json\/wp\/v2\/posts\/6992","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.packqc.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/de\/wp-json\/wp\/v2\/comments?post=6992"}],"version-history":[{"count":0,"href":"https:\/\/www.packqc.com\/de\/wp-json\/wp\/v2\/posts\/6992\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/de\/wp-json\/wp\/v2\/media?parent=6992"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.packqc.com\/de\/wp-json\/wp\/v2\/categories?post=6992"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.packqc.com\/de\/wp-json\/wp\/v2\/tags?post=6992"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}