{"id":9840,"date":"2026-02-24T15:11:44","date_gmt":"2026-02-24T07:11:44","guid":{"rendered":"https:\/\/www.packqc.com\/standard\/astm-f1115-2\/"},"modified":"2026-04-16T09:53:22","modified_gmt":"2026-04-16T01:53:22","slug":"astm-f1115","status":"publish","type":"standard","link":"https:\/\/www.packqc.com\/hu\/standard\/astm-f1115\/","title":{"rendered":"ASTM F1115"},"content":{"rendered":"<h2 class=\"wp-block-heading\">ASTM F1115 \u00e9s ipari jelent\u0151s\u00e9ge<\/h2>\n\n\n\n<p>A sz\u00e9n-dioxid (CO\u2082) visszatart\u00e1s\u00e1nak biztos\u00edt\u00e1sa a sz\u00e9nsavas italokban a csomagol\u00e1s integrit\u00e1s\u00e1nak \u00e9s a term\u00e9k min\u0151s\u00e9g\u00e9nek kritikus szempontja. <strong data-start=\"603\" data-end=\"617\">ASTM F1115<\/strong>, hivatalos c\u00edme <em data-start=\"637\" data-end=\"722\">Szabv\u00e1nyos vizsg\u00e1lati m\u00f3dszer italos tart\u00e1lyok sz\u00e9n-dioxid vesztes\u00e9g\u00e9nek meghat\u00e1roz\u00e1s\u00e1ra<\/em>, tudom\u00e1nyosan hiteles\u00edtett keretet biztos\u00edt a CO\u2082-vesztes\u00e9g id\u0151beli m\u00e9r\u00e9s\u00e9re. A csomagol\u00e1si szakemberek \u00e9s az italgy\u00e1rt\u00f3k sz\u00e1m\u00e1ra ez a szabv\u00e1ny alapvet\u0151 fontoss\u00e1g\u00fa a tart\u00e1lyok teljes\u00edtm\u00e9ny\u00e9nek \u00e9rt\u00e9kel\u00e9s\u00e9hez \u00e9s az eltarthat\u00f3s\u00e1g optimaliz\u00e1l\u00e1s\u00e1hoz.<\/p>\n\n\n\n<p>A sz\u00e9nsavtartalom fenntart\u00e1sa k\u00f6zvetlen\u00fcl befoly\u00e1solja az \u00edzt, a sz\u00e1j\u00e9rzetet \u00e9s a fogyaszt\u00f3i el\u00e9gedetts\u00e9get. Mivel az ipar\u00e1g a min\u0151s\u00e9gbiztos\u00edt\u00e1st helyezi el\u0151t\u00e9rbe, <strong data-start=\"1083\" data-end=\"1131\">Cell Instruments\u2019 karboniz\u00e1ci\u00f3s tesztberendez\u00e9s<\/strong>, k\u00fcl\u00f6n\u00f6sen a nagy pontoss\u00e1g\u00fa g\u00e1zmennyis\u00e9gm\u00e9r\u0151nk, az ASTM F1115 szabv\u00e1nyhoz igazodik, hogy megism\u00e9telhet\u0151 \u00e9s pontos eredm\u00e9nyeket szolg\u00e1ltasson.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Karboniz\u00e1ci\u00f3s vizsg\u00e1lati elj\u00e1r\u00e1s az ASTM F1115 szabv\u00e1nyban<\/h2>\n\n\n\n<p>A <strong data-start=\"1326\" data-end=\"1346\">karboniz\u00e1ci\u00f3s teszt<\/strong> az ASTM F1115 szerint k\u00e9t alapvet\u0151 elj\u00e1r\u00e1st foglal mag\u00e1ban - az A \u00e9s a B elj\u00e1r\u00e1st -, amelyek mindegyike k\u00fcl\u00f6nb\u00f6z\u0151 vizsg\u00e1lati k\u00f6rnyezetekhez \u00e9s pontoss\u00e1gi ig\u00e9nyekhez alkalmas.<\/p>\n\n\n\n<p><strong data-start=\"1493\" data-end=\"1508\">A elj\u00e1r\u00e1s<\/strong> jellemz\u0151en a k\u00f6vetkez\u0151 esetekben alkalmazz\u00e1k <strong data-start=\"1533\" data-end=\"1553\">K+F laborat\u00f3riumok<\/strong>. Nagyon \u00e9rz\u00e9keny m\u0171szereket, p\u00e9ld\u00e1ul mikronyom\u00e1s-jel\u00e1talak\u00edt\u00f3kat \u00e9s h\u0151elemeket haszn\u00e1l a bels\u0151 nyom\u00e1s \u00e9s h\u0151m\u00e9rs\u00e9klet z\u00e1rt rendszerekben t\u00f6rt\u00e9n\u0151 megfigyel\u00e9s\u00e9re. Ez lehet\u0151v\u00e9 teszi a CO\u2082 visszatart\u00e1s\u00e1nak r\u00e9szletes nyomon k\u00f6vet\u00e9s\u00e9t a hossz\u00fa t\u00e1v\u00fa t\u00e1rol\u00e1si szimul\u00e1ci\u00f3k sor\u00e1n.<\/p>\n\n\n\n<p><strong data-start=\"1797\" data-end=\"1812\">B elj\u00e1r\u00e1s<\/strong>, amelyet leggyakrabban gy\u00e1rt\u00f3sorokon haszn\u00e1lnak, alkalmazza a <strong data-start=\"1862\" data-end=\"1899\">k\u00e9zi vagy automatiz\u00e1lt CO\u2082-elemz\u0151 k\u00e9sz\u00fcl\u00e9kek<\/strong>. Ez a m\u00f3dszer k\u00fcl\u00f6n\u00f6sen praktikus <strong data-start=\"1941\" data-end=\"1991\">min\u0151s\u00e9gellen\u0151rz\u00e9s az italok t\u00f6lt\u00e9se sor\u00e1n<\/strong>, ahol a sz\u00e9nsavtartalom gyors ellen\u0151rz\u00e9se kritikus fontoss\u00e1g\u00fa.<\/p>\n\n\n\n<p>Mindk\u00e9t elj\u00e1r\u00e1shoz sz\u00fcks\u00e9ges legfontosabb felszerel\u00e9sek:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Palacknyom\u00e1s- \u00e9s h\u0151m\u00e9rs\u00e9kletm\u00e9r\u0151 eszk\u00f6z\u00f6k<\/li>\n\n\n\n<li><strong data-start=\"2160\" data-end=\"2182\">G\u00e1zmennyis\u00e9g-vizsg\u00e1l\u00f3 k\u00e9sz\u00fcl\u00e9kek<\/strong> CO\u2082 tartalomelemz\u00e9shez<\/li>\n\n\n\n<li>Termoelemek vagy ellen\u0151rz\u0151 palackok a k\u00f6vetkezetes h\u0151m\u00e9rs\u00e9kletk\u00f6vet\u00e9shez<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"CLRT-01 Sz\u00e9n-dioxid t\u00e9rfogat teszter\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/xiL6aKjUDno?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<\/div><\/figure>\n\n\n\n<p><strong data-start=\"2284\" data-end=\"2323\"><a href=\"https:\/\/www.packqc.com\/hu\/\">Cell Instruments<\/a>\u2019 g\u00e1z t\u00e9rfogat teszter<\/strong> kiv\u00e1l\u00f3 kompatibilit\u00e1st biztos\u00edt mindk\u00e9t vizsg\u00e1lati elj\u00e1r\u00e1ssal. A gyors be\u00e1ll\u00edt\u00e1sra \u00e9s megb\u00edzhat\u00f3 m\u00e9r\u00e9sekre tervezett k\u00e9sz\u00fcl\u00e9k biztos\u00edtja, hogy a palackoz\u00f3k k\u00f6vetkezetes CO\u2082-t\u00f6lt\u00e9si szinteket tarthassanak fenn, \u00e9s megel\u0151zhess\u00e9k a term\u00e9k korai roml\u00e1s\u00e1t.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">A karboniz\u00e1ci\u00f3s vesztes\u00e9get befoly\u00e1sol\u00f3 kritikus t\u00e9nyez\u0151k<\/h2>\n\n\n\n<p>Sz\u00e1mos v\u00e1ltoz\u00f3 befoly\u00e1solhatja a vizsg\u00e1lat pontoss\u00e1g\u00e1t, illetve a gyakorlatban a t\u00e9nyleges sz\u00e9nsavvesztes\u00e9get:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"2699\" data-end=\"2718\">Z\u00e1r\u00f3d\u00e1s sziv\u00e1rg\u00e1s<\/strong> a nem megfelel\u0151 lez\u00e1r\u00e1s vagy a palack befejez\u00e9s\u00e9nek hib\u00e1i miatt<\/li>\n\n\n\n<li>A CO\u2082-egyens\u00falyt befoly\u00e1sol\u00f3 k\u00f6rnyezeti h\u0151m\u00e9rs\u00e9klet-ingadoz\u00e1sok<\/li>\n\n\n\n<li>T\u00fal nagy t\u00e9rfogat vagy leveg\u0151tartalom a palackokban<\/li>\n\n\n\n<li><strong data-start=\"2885\" data-end=\"2931\">Pontatlan nyom\u00e1s- vagy h\u0151m\u00e9rs\u00e9klet-\u00e9rz\u00e9kel\u0151k<\/strong><\/li>\n<\/ul>\n\n\n\n<p>Ez\u00e9rt, <strong data-start=\"2946\" data-end=\"2960\">ASTM F1115<\/strong> hangs\u00falyozza a k\u00f6rnyezeti kondicion\u00e1l\u00e1s (23 \u00b0C \u00b12 \u00b0C \u00e9s 50% \u00b15% RH) \u00e9s a m\u00e9r\u00e9sek ak\u00e1r 16 hetes id\u0151k\u00f6z\u00f6nk\u00e9nt t\u00f6rt\u00e9n\u0151 megism\u00e9tl\u00e9s\u00e9nek fontoss\u00e1g\u00e1t.<\/p>\n\n\n\n<p>A kiv\u00e1l\u00f3 min\u0151s\u00e9g\u0171 m\u00e9r\u0151eszk\u00f6z\u00f6k haszn\u00e1lata itt kritikus fontoss\u00e1g\u00fa. <strong data-start=\"3167\" data-end=\"3215\">Az Cell Instruments g\u00e1zmennyis\u00e9g-vizsg\u00e1l\u00f3t biztos\u00edt<\/strong> amelyek a h\u0151m\u00e9rs\u00e9klet-kompenz\u00e1ci\u00f3 \u00e9s az adatnapl\u00f3z\u00e1si k\u00e9pess\u00e9gek integr\u00e1l\u00e1s\u00e1val minimaliz\u00e1lj\u00e1k a hib\u00e1kat, \u00e9s ezzel egyszer\u0171s\u00edtik a karboniz\u00e1ci\u00f3 nyomon k\u00f6vet\u00e9si folyamat\u00e1t.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Az ASTM F1115 vizsg\u00e1lat alkalmaz\u00e1sai \u00e9s el\u0151nyei<\/h2>\n\n\n\n<p>Az ASTM F1115 karboniz\u00e1ci\u00f3s teszt nem csak a megfelel\u0151s\u00e9gr\u0151l sz\u00f3l, hanem hasznos inform\u00e1ci\u00f3kkal szolg\u00e1l a k\u00f6vetkez\u0151kh\u00f6z:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"3519\" data-end=\"3553\">Italcsomagol\u00e1s-fejleszt\u00e9s<\/strong><\/li>\n\n\n\n<li><strong data-start=\"3558\" data-end=\"3583\">Az eltarthat\u00f3s\u00e1gi id\u0151 el\u0151rejelz\u00e9se<\/strong> CO\u2082 visszatart\u00e1si g\u00f6rb\u00e9k alapj\u00e1n<\/li>\n\n\n\n<li><strong data-start=\"3618\" data-end=\"3647\">A z\u00e1r\u00f3rendszer valid\u00e1l\u00e1sa<\/strong><\/li>\n\n\n\n<li><strong data-start=\"3652\" data-end=\"3687\">Gy\u00e1rt\u00f3sori min\u0151s\u00e9gellen\u0151rz\u00e9s<\/strong><\/li>\n<\/ul>\n\n\n\n<p>A karboniz\u00e1ci\u00f3 id\u0151beli boml\u00e1s\u00e1nak \u00e9rt\u00e9kel\u00e9s\u00e9vel a gy\u00e1rt\u00f3k ki tudj\u00e1k v\u00e1lasztani a legmegfelel\u0151bb anyagokat, tart\u00e1lygeometri\u00e1kat \u00e9s z\u00e1r\u00f3rendszereket. Emellett a CO\u2082-visszatart\u00e1si adatok elt\u00e9r\u00e9sei gyorsan jelezhetik a termel\u00e9si anom\u00e1li\u00e1kat, lehet\u0151v\u00e9 t\u00e9ve a korai beavatkoz\u00e1st.<\/p>\n\n\n\n<p>at <strong data-start=\"3952\" data-end=\"3972\">Cell Instruments<\/strong>, t\u00e1mogatjuk az italgy\u00e1rt\u00f3 c\u00e9geket pontos <strong data-start=\"4017\" data-end=\"4047\">karboniz\u00e1ci\u00f3s vizsg\u00e1lati megold\u00e1sok<\/strong> amelyek az ASTM F1115 protokollt k\u00f6vetik. G\u00e1zt\u00e9rfogat-vizsg\u00e1l\u00f3ink seg\u00edtenek m\u00e9g a kisebb CO\u2082-v\u00e1ltoz\u00e1sok kimutat\u00e1s\u00e1ban is, hozz\u00e1j\u00e1rulva az optim\u00e1lis term\u00e9kfejleszt\u00e9shez \u00e9s a fogyaszt\u00f3i el\u00e9gedetts\u00e9ghez.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Biztos\u00edtsa az italok min\u0151s\u00e9g\u00e9t az ASTM F1115-nek megfelel\u0151 tesztel\u00e9ssel<\/h2>\n\n\n\n<p>Megfelel\u00e9s a <strong data-start=\"4956\" data-end=\"4970\">ASTM F1115<\/strong> nemcsak a jogszab\u00e1lyi el\u0151\u00edr\u00e1sok betart\u00e1s\u00e1t, hanem az italok jobb min\u0151s\u00e9g\u00e9t \u00e9s hosszabb eltarthat\u00f3s\u00e1g\u00e1t is biztos\u00edtja. A sz\u00e9nsavtartalom-vizsg\u00e1lati m\u00f3dszer megb\u00edzhat\u00f3 <strong data-start=\"5125\" data-end=\"5147\">g\u00e1zmennyis\u00e9g-m\u00e9r\u0151k<\/strong>, a gy\u00e1rt\u00f3k \u00e9rt\u00e9kes betekint\u00e9st nyernek csomagol\u00e1si rendszereik integrit\u00e1s\u00e1ba.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">A megfelel\u0151 g\u00e1zmennyis\u00e9g-vizsg\u00e1l\u00f3 kiv\u00e1laszt\u00e1sa az ASTM F1115 szabv\u00e1nynak val\u00f3 megfelel\u00e9shez<\/h2>\n\n\n\n<p>A megfelel\u0151 vizsg\u00e1lati eszk\u00f6z kiv\u00e1laszt\u00e1sa d\u00f6nt\u0151 fontoss\u00e1g\u00fa az al\u00e1bbiak sikeres v\u00e9grehajt\u00e1s\u00e1hoz <a href=\"https:\/\/store.astm.org\/f1115-16r23.html\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">ASTM F1115<\/a>. A <strong data-start=\"4395\" data-end=\"4434\">Cell Instruments <a href=\"https:\/\/www.packqc.com\/hu\/product-category\/carbonation-tester\/\">karboniz\u00e1ci\u00f3s teszter<\/a><\/strong> a k\u00f6vetkez\u0151kre tervezt\u00e9k:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>A nyom\u00e1s \u00e9s a CO\u2082-tartalom pontos m\u00e9r\u00e9se<\/li>\n\n\n\n<li>Kompatibilit\u00e1s mind az A, mind a B elj\u00e1r\u00e1ssal<\/li>\n\n\n\n<li>Hossz\u00fa t\u00e1v\u00fa stabilit\u00e1s ism\u00e9telt m\u00e9r\u00e9sekhez<\/li>\n\n\n\n<li>Egyszer\u0171 m\u0171k\u00f6d\u00e9s laborat\u00f3riumi \u00e9s termel\u00e9si k\u00f6rnyezetekben<\/li>\n\n\n\n<li>Rendszer\u00fcnk t\u00e1mogatja a r\u00e9szletes jelent\u00e9st\u00e9telt \u00e9s a sz\u00e9nsavtartalom grafikus megjelen\u00edt\u00e9s\u00e9t az id\u0151 m\u00fal\u00e1s\u00e1val, megk\u00f6nny\u00edtve ezzel az eltarthat\u00f3s\u00e1gi becsl\u00e9sek levezet\u00e9s\u00e9t \u00e9s a csomagol\u00e1si teljes\u00edtm\u00e9ny trendjeinek elemz\u00e9s\u00e9t.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\n\t\t\t\tKapcsolatfelv\u00e9tel Karboniz\u00e1ci\u00f3s vizsg\u00e1lati megold\u00e1s beszerz\u00e9se\t\t\t\t<\/h2>\n\n\n\n<p><strong data-start=\"5236\" data-end=\"5256\">Cell Instruments<\/strong> tov\u00e1bbra is elk\u00f6telezett az italcsomagol\u00e1s tudom\u00e1ny\u00e1nak robusztus, pontos \u00e9s felhaszn\u00e1l\u00f3bar\u00e1t CO\u2082-m\u00e9r\u0151 m\u0171szerekkel t\u00f6rt\u00e9n\u0151 fejleszt\u00e9se mellett. Vegye fel vel\u00fcnk a kapcsolatot, hogy megtudja, hogyan t\u00e1mogatj\u00e1k megold\u00e1saink az \u00d6n csomagol\u00e1si innov\u00e1ci\u00f3s \u00e9s min\u0151s\u00e9gellen\u0151rz\u00e9si c\u00e9ljait.<\/p>","protected":false},"excerpt":{"rendered":"<p>ASTM F1115 and Its Industry Significance Ensuring carbon dioxide (CO\u2082) retention in carbonated beverages is a critical aspect of packaging integrity and product quality. ASTM F1115, officially titled Standard Test Method for Determining the Carbon Dioxide Loss of Beverage Containers, provides a scientifically validated framework to measure CO\u2082 loss over time. For packaging professionals and [&hellip;]<\/p>","protected":false},"featured_media":8430,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"standard-category":[611],"class_list":["post-9840","standard","type-standard","status-publish","has-post-thumbnail","hentry","standard-category-astm"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/hu\/wp-json\/wp\/v2\/standard\/9840","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/hu\/wp-json\/wp\/v2\/standard"}],"about":[{"href":"https:\/\/www.packqc.com\/hu\/wp-json\/wp\/v2\/types\/standard"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/hu\/wp-json\/wp\/v2\/media\/8430"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/hu\/wp-json\/wp\/v2\/media?parent=9840"}],"wp:term":[{"taxonomy":"standard-category","embeddable":true,"href":"https:\/\/www.packqc.com\/hu\/wp-json\/wp\/v2\/standard-category?post=9840"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}