{"id":9841,"date":"2026-02-24T15:11:45","date_gmt":"2026-02-24T07:11:45","guid":{"rendered":"https:\/\/www.packqc.com\/standard\/iso-8295-2\/"},"modified":"2026-03-13T15:25:46","modified_gmt":"2026-03-13T07:25:46","slug":"iso-8295","status":"publish","type":"standard","link":"https:\/\/www.packqc.com\/kk\/standard\/iso-8295\/","title":{"rendered":"ISO 8295"},"content":{"rendered":"<h2 class=\"wp-block-heading\">ISO 8295 Is Important for Plastic Film Manufacturers<\/h2>\n\n\n\n<p>For film producers and packaging converters, <strong data-start=\"2773\" data-end=\"2785\">ISO 8295<\/strong> testing is a cornerstone of <strong data-start=\"2814\" data-end=\"2833\">\u0441\u0430\u043f\u0430\u0441\u044b\u043d \u0431\u0430\u049b\u044b\u043b\u0430\u0443<\/strong>. The slip behavior of plastic films\u2014whether polyethylene, polypropylene, polyester, or multilayer laminates\u2014can change due to:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Additive migration (e.g., slip agents like erucamide)<\/li>\n\n\n\n<li>Surface treatments (e.g., corona, plasma)<\/li>\n\n\n\n<li>Environmental exposure (aging or humidity)<\/li>\n\n\n\n<li>Handling conditions during shipping and processing<\/li>\n<\/ul>\n\n\n\n<p>Accurate COF measurements help ensure the film performs well throughout its lifecycle\u2014from converting and printing to sealing and final application.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Coefficient of Friction of Film and COF of Plastic Film in Packaging<\/h2>\n\n\n\n<p>The <strong data-start=\"944\" data-end=\"979\">coefficient of friction of film<\/strong>, often referred to as <strong data-start=\"1002\" data-end=\"1025\">COF of plastic film<\/strong>, measures how easily one layer of film slides over another. This property significantly influences machinability on form-fill-seal equipment, pouching lines, and automated stacking processes. Poor slip characteristics can lead to equipment jams or misfeeds, while overly slippery films may cause sealing problems or product misalignment.<\/p>\n\n\n\n<p><strong data-start=\"1365\" data-end=\"1377\">ISO 8295<\/strong> specifically provides a standardized method for testing both <strong data-start=\"1439\" data-end=\"1449\">\u0441\u0442\u0430\u0442\u0438\u043a\u0430\u043b\u044b\u049b<\/strong> \u0436\u04d9\u043d\u0435 <strong data-start=\"1454\" data-end=\"1490\">dynamic coefficients of friction<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"1495\" data-end=\"1509\">\u0421\u0442\u0430\u0442\u0438\u043a\u0430\u043b\u044b\u049b COF<\/strong> (\u03bcs) measures the resistance at the start of motion.<\/li>\n\n\n\n<li><strong data-start=\"1565\" data-end=\"1580\">Dynamic COF<\/strong> (\u03bcd) measures resistance during continued sliding.<\/li>\n<\/ul>\n\n\n\n<p>This distinction is vital for applications such as vertical form fill seal (VFFS) where packaging films must initiate and maintain smooth movement under load.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Overview of ISO 8295 Testing Method<\/h2>\n\n\n\n<p>ISO 8295 outlines a laboratory method for evaluating slip properties by sliding a sled across a test specimen placed on a horizontal test surface. The apparatus generally includes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0410 <strong data-start=\"2025\" data-end=\"2033\">\u0448\u0430\u043d\u0430<\/strong> with a standardized weight (typically 200g \u00b129g) and contact area.<\/li>\n\n\n\n<li>\u0410 <strong data-start=\"2105\" data-end=\"2124\">motorized stage<\/strong> or a tensile testing machine to apply uniform motion.<\/li>\n\n\n\n<li>\u0410 <strong data-start=\"2183\" data-end=\"2209\">force-measuring device<\/strong> to record frictional resistance.<\/li>\n<\/ul>\n\n\n\n<p>Key parameters defined in ISO 8295 include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"2291\" data-end=\"2306\">\u0421\u044b\u043d\u0430\u049b \u0436\u044b\u043b\u0434\u0430\u043c\u0434\u044b\u0493\u044b:<\/strong> Normally 100 mm\/min \u00b110 mm\/min<\/li>\n\n\n\n<li><strong data-start=\"2340\" data-end=\"2372\">Contact time before sliding:<\/strong> 15 seconds<\/li>\n\n\n\n<li><strong data-start=\"2386\" data-end=\"2410\">Sample conditioning:<\/strong> 23\u00b0C, 50% RH for at least 16 hours per ISO 291<\/li>\n<\/ul>\n\n\n\n<p>Measurements are typically taken over multiple film pairs to ensure statistical accuracy. The results help assess uniformity across a production batch or compare formulations with varying slip agents.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"\u0421\u04af\u0440\u0442\u0443 \u043a\u043e\u044d\u0444\u0444\u0438\u0446\u0438\u0435\u043d\u0442\u0456\u043d \u0430\u043d\u044b\u049b\u0442\u0430\u0443 \u0441\u044b\u043d\u0430\u049b \u043f\u0440\u043e\u0446\u0435\u0441\u0456\u043d\u0456\u04a3 \u04d9\u0434\u0456\u0441\u0456 \u049b\u0430\u043d\u0434\u0430\u0439?\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/NUgXENOz8J0?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Common Applications of ISO 8295 Testing<\/h2>\n\n\n\n<p>Industries using ISO 8295 COF data include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"3408\" data-end=\"3427\">Food packaging:<\/strong> To optimize vertical and horizontal bagging systems<\/li>\n\n\n\n<li><strong data-start=\"3482\" data-end=\"3511\">\u041c\u0435\u0434\u0438\u0446\u0438\u043d\u0430\u043b\u044b\u049b \u049b\u04b1\u0440\u044b\u043b\u0493\u044b\u043b\u0430\u0440\u0434\u044b \u049b\u0430\u043f\u0442\u0430\u0443:<\/strong> Ensuring sterile barrier packaging doesn\u2019t stick or slide excessively<\/li>\n\n\n\n<li><strong data-start=\"3584\" data-end=\"3614\">Adhesive labels and tapes:<\/strong> Where release liner performance depends on friction characteristics<\/li>\n\n\n\n<li><strong data-start=\"3685\" data-end=\"3714\">\u0424\u0430\u0440\u043c\u0430\u0446\u0435\u0432\u0442\u0438\u043a\u0430\u043b\u044b\u049b \u049b\u0430\u043f\u0442\u0430\u043c\u0430:<\/strong> To maintain dimensional stability during blister packing<\/li>\n<\/ul>\n\n\n\n<p>Understanding the COF also supports <strong data-start=\"3809\" data-end=\"3834\">\u0440\u0435\u0442\u0442\u0435\u0443 \u0442\u0430\u043b\u0430\u043f\u0442\u0430\u0440\u044b\u043d\u0430 \u0441\u04d9\u0439\u043a\u0435\u0441\u0442\u0456\u043a<\/strong>, particularly where machinability and safety are concerned.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Choosing the right Coefficient Of Friction Tester<\/h2>\n\n\n\n<p>To implement ISO 8295 in your lab, you need precise instrumentation that meets the standard&#8217;s requirements. The <strong data-start=\"4086\" data-end=\"4137\"><a href=\"https:\/\/www.packqc.com\/kk\/\">\u0416\u0430\u0441\u0443\u0448\u0430 \u049b\u04b1\u0440\u0430\u043b\u0434\u0430\u0440\u044b<\/a> \u04ae\u0439\u043a\u0435\u043b\u0456\u0441 \u043a\u043e\u044d\u0444\u0444\u0438\u0446\u0438\u0435\u043d\u0442\u0456\u043d \u0441\u044b\u043d\u0430\u0443\u0448\u044b<\/strong> is designed to:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Accurately measure both static and dynamic COF<\/li>\n\n\n\n<li>Support friction testing of films against film, metal, or other surfaces<\/li>\n\n\n\n<li>Offer programmable test speeds and load configurations<\/li>\n\n\n\n<li>Provide digital outputs for easy data analysis and quality documentation<\/li>\n<\/ul>\n\n\n\n<p>Whether you&#8217;re testing polyethylene film, BOPP, PET, or multilayer laminates, Cell Instruments&#8217; testers ensure <strong data-start=\"4523\" data-end=\"4537\">\u049b\u0430\u0439\u0442\u0430\u043b\u0430\u043d\u0430\u0442\u044b\u043d<\/strong>, <strong data-start=\"4539\" data-end=\"4561\">\u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u049b\u0430 \u0441\u04d9\u0439\u043a\u0435\u0441<\/strong>, \u0436\u04d9\u043d\u0435 <strong data-start=\"4567\" data-end=\"4601\">high-precision COF measurement<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\n\t\t\t\t\u0411\u0456\u0437\u0431\u0435\u043d \u0431\u0430\u0439\u043b\u0430\u043d\u044b\u0441\u044b\u04a3\u044b\u0437 \u0436\u04d9\u043d\u0435 \u04af\u0439\u043a\u0435\u043b\u0456\u0441 \u043a\u043e\u044d\u0444\u0444\u0438\u0446\u0438\u0435\u043d\u0442\u0456\u043d \u0441\u044b\u043d\u0430\u0443 \u0448\u0435\u0448\u0456\u043c\u0456\u043d \u0430\u043b\u044b\u04a3\u044b\u0437\t\t\t\t<\/h2>\n\n\n\n<p>\u0421\u0456\u0437 \u0431\u043e\u043b\u0441\u0430\u04a3\u044b\u0437 \u0434\u0430 <strong data-start=\"5354\" data-end=\"5417\">\u043f\u043b\u0430\u0441\u0442\u043c\u0430\u0441\u0441\u0430\u043b\u0430\u0440, \u049b\u0430\u0493\u0430\u0437, \u049b\u0430\u043f\u0442\u0430\u043c\u0430 \u043d\u0435\u043c\u0435\u0441\u0435 \u043c\u0435\u0434\u0438\u0446\u0438\u043d\u0430\u043b\u044b\u049b \u049b\u04b1\u0440\u044b\u043b\u0493\u044b\u043b\u0430\u0440\u0434\u044b \u04e9\u043d\u0434\u0456\u0440\u0443<\/strong>, understanding and applying ISO 8295 gives you a competitive edge. With the right <strong data-start=\"5506\" data-end=\"5540\">\u0441\u044b\u0440\u0493\u0430\u043d\u0430\u0443 \u043a\u043e\u044d\u0444\u0444\u0438\u0446\u0438\u0435\u043d\u0442\u0456\u043d \u0441\u044b\u043d\u0430\u0443\u0448\u044b<\/strong> \u0441\u0438\u044f\u049b\u0442\u044b <a href=\"https:\/\/www.packqc.com\/kk\/product\/coefficient-of-friction-testing-equipment\/\"><strong>COF-01 <\/strong><\/a>Cell Instruments-\u0442\u0456\u04a3 \u0430\u0440\u049b\u0430\u0441\u044b\u043d\u0434\u0430 \u0441\u0456\u0437\u0434\u0456\u04a3 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u044f\u043b\u0430\u0440\u044b\u04a3\u044b\u0437 \u04af\u0439\u043b\u0435\u0441\u0456\u043c\u0434\u0456, \u0442\u0438\u0456\u043c\u0434\u0456 \u0436\u04d9\u043d\u0435 \u0442\u0430\u043b\u0430\u043f\u0442\u0430\u0440\u0493\u0430 \u0441\u0430\u0439 \u0431\u043e\u043b\u0430\u0434\u044b.<\/p>\n\n\n\n<p>\u0411\u0430\u0439\u043b\u0430\u043d\u044b\u0441 <strong>\u0416\u0430\u0441\u0443\u0448\u0430 \u049b\u04b1\u0440\u0430\u043b\u0434\u0430\u0440\u044b<\/strong> \u0411\u04af\u0433\u0456\u043d \u0431\u0456\u0437\u0434\u0456\u04a3 \u0448\u0435\u0448\u0456\u043c\u0434\u0435\u0440\u0456\u043c\u0456\u0437\u0434\u0456\u04a3 \u0441\u0456\u0437\u0434\u0456\u04a3 \u0441\u044b\u043d\u0430\u0443 \u043c\u04af\u043c\u043a\u0456\u043d\u0434\u0456\u043a\u0442\u0435\u0440\u0456\u04a3\u0456\u0437\u0434\u0456 \u0436\u04d9\u043d\u0435 \u04e9\u043d\u0456\u043c \u0441\u0430\u043f\u0430\u0441\u044b\u043d \u049b\u0430\u043b\u0430\u0439 \u0436\u0430\u049b\u0441\u0430\u0440\u0442\u0430 \u0430\u043b\u0430\u0442\u044b\u043d\u044b\u043d \u0431\u0456\u043b\u0443 \u04af\u0448\u0456\u043d.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u0416\u0438\u0456 \u049b\u043e\u0439\u044b\u043b\u0430\u0442\u044b\u043d \u0441\u04b1\u0440\u0430\u049b\u0442\u0430\u0440<\/h2>\n\n\n\n<p>1. What is ISO 8295 used for?<br>ISO 8295 is used to measure the static and dynamic coefficients of friction of plastic films and sheeting, helping assess slip properties for processing and handling.<\/p>\n\n\n\n<p>2. Why is COF important in packaging films?<br>The coefficient of friction impacts machinability, stacking, sealing, and transport of films. Proper COF ensures smooth processing and prevents issues like sticking or misfeeding.<\/p>\n\n\n\n<p>3. How do additives affect COF?<br>Slip additives migrate to the surface over time and reduce friction. However, their effect can vary with age, humidity, and formulation, making COF testing crucial.<\/p>\n\n\n\n<p>4. \u0418\u04d9, \u043c\u04af\u043c\u043a\u0456\u043d <a href=\"https:\/\/www.iso.org\/standard\/20760.html\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">ISO 8295<\/a> be used for non-film materials?<br>It is primarily designed for plastic films up to 0.5 mm, but with adjustments, it can also test films against metal, paper, or other substrates.<\/p>\n\n\n\n<p><\/p>","protected":false},"featured_media":6059,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"class_list":["post-9841","standard","type-standard","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/kk\/wp-json\/wp\/v2\/standard\/9841","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/kk\/wp-json\/wp\/v2\/standard"}],"about":[{"href":"https:\/\/www.packqc.com\/kk\/wp-json\/wp\/v2\/types\/standard"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/kk\/wp-json\/wp\/v2\/media\/6059"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/kk\/wp-json\/wp\/v2\/media?parent=9841"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}