{"id":9561,"date":"2026-02-02T14:53:11","date_gmt":"2026-02-02T06:53:11","guid":{"rendered":"https:\/\/www.packqc.com\/products\/sale-friction-peel-tester-manufacturer\/"},"modified":"2026-04-14T16:03:04","modified_gmt":"2026-04-14T08:03:04","slug":"sale-friction-peel-tester-manufacturer","status":"publish","type":"products","link":"https:\/\/www.packqc.com\/lt\/products\/sale-friction-peel-tester-manufacturer\/","title":{"rendered":"FPT-01 trinties lupimo testeris"},"content":{"rendered":"<p>The&nbsp;<strong>Trinties lupimo testeris<\/strong>&nbsp;yra pa\u017eangi priemon\u0117, skirta dviem kritin\u0117ms med\u017eiag\u0173 bandymo savyb\u0117ms \u012fvertinti:&nbsp;<strong>Trinties koeficientas (COF)<\/strong>&nbsp;ir&nbsp;<strong>lupimo j\u0117ga<\/strong>. \u0160ie bandymai b\u016btini pakavimo, medicinos prietais\u0173, farmacijos, tekstil\u0117s, klij\u0173 ir kitose pramon\u0117s \u0161akose. U\u017etikrinant, kad gaminiai atitikt\u0173 trinties ir lupimo standartus, garantuojamas funkcionalumas, saugumas ir na\u0161umas. The&nbsp;<strong>Trinties lupimo testeris<\/strong>&nbsp;si\u016blo tiksl\u0173, universal\u0173 ir patikim\u0105 sprendim\u0105 abiem&nbsp;<strong>COF testai<\/strong>&nbsp;ir nulupimo bandymai, leid\u017eiantys gamintojams pagerinti savo kokyb\u0117s kontrol\u0117s procesus ir kurti geresnius produktus.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pagrindin\u0117s trinties lupimo testerio savyb\u0117s ir privalumai<\/h2>\n\n\n\n<p>The&nbsp;<strong>Trinties lupimo testeris<\/strong>&nbsp;sujungia dvigubas testavimo galimybes viename efektyviame \u012frenginyje, tod\u0117l jis idealiai tinka \u012fvairioms med\u017eiagoms, \u012fskaitant plastikines pl\u0117veles, popieri\u0173, tekstil\u0119 ir lipniuosius gaminius. Tai leid\u017eia vartotojams atlikti \u0161iuos veiksmus:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>COF testavimas<\/strong>: Matuoja abu\u00a0<strong>statiniai ir kinetiniai trinties koeficientai<\/strong>. Statinis COF nustato trint\u012f tarp dviej\u0173 med\u017eiag\u0173, kai jos yra ramyb\u0117s b\u016bsenoje, o kinetinis COF matuoja trint\u012f, kai med\u017eiagos juda. \u0160is skirtumas yra labai svarbus norint suprasti, kaip med\u017eiagos s\u0105veikauja viena su kita skirtingais naudojimo etapais.<\/li>\n\n\n\n<li><strong>Nulupimo j\u0117gos bandymas<\/strong>: \u012fvertina j\u0117g\u0105, reikaling\u0105 atskirti du suri\u0161tus sluoksnius, pvz., lipnias juostas, atpalaiduojan\u010dius \u012fd\u0117klus ir medicininius klijus. \u0160is testas padeda \u012fvertinti atskyrimo lengvum\u0105 ir u\u017etikrina gaminio patikimum\u0105.<\/li>\n<\/ul>\n\n\n\n<p>Testeris valdomas per a&nbsp;<strong>PLC sistema<\/strong>&nbsp;su intuityviu&nbsp;<strong>HMI jutiklinio ekrano s\u0105saja<\/strong>. Jis si\u016blo tiksl\u0173 valdym\u0105, nes a&nbsp;<strong>rutulinio \u0161vino var\u017eto mechanizmas<\/strong>, kuris u\u017etikrina pastov\u0173 greit\u012f ir poslink\u012f bandym\u0173 metu. Tikralaikis bandym\u0173 duomen\u0173 rodymas leid\u017eia nedelsiant atlikti analiz\u0119, u\u017etikrinant, kad vartotojai, remdamiesi rezultatais, gal\u0117t\u0173 koreguoti gamybos parametrus arba patobulinti gaminio dizain\u0105.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Trinties lupimo testerio bandymo metodai<\/h2>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"FPT-01 Trinties ir lupimosi stiprumo testeris su trinties koeficiento funkcija\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/QpwY4XRM9JI?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<\/div><\/figure>\n\n\n\n<p><strong style=\"color: var(--ast-global-color-2); font-family: Montserrat, sans-serif; font-size: 1.6rem; font-style: inherit; text-align: var(--text-align); background-color: var(--ast-global-color-4);\">Trinties koeficiento (COF) bandymas<\/strong><\/p>\n\n\n\n<p>COF testai yra labai svarb\u016bs nustatant, kaip du pavir\u0161iai s\u0105veikauja, kai jie lie\u010diasi, ypa\u010d pakavimo pramon\u0117je, kur med\u017eiagos, pvz., plastikin\u0117s pl\u0117vel\u0117s, austi mai\u0161eliai ar kartonas, turi skland\u017eiai jud\u0117ti ma\u0161inose, nesulipdami ir neply\u0161dami.<\/p>\n\n\n\n<p>A <strong>COF testas<\/strong>, m\u0117ginio med\u017eiaga dedama ant lygaus pavir\u0161iaus, per j\u012f kontroliuojamu grei\u010diu velkant \u017einomo svorio roges. Testeris matuoja j\u0117g\u0105, reikaling\u0105 rogi\u0173 jud\u0117jimui prad\u0117ti ir palaikyti, pateikdamas tiek statines, tiek kinetin\u0117s COF reik\u0161mes. \u0160ios vert\u0117s padeda gamintojams nustatyti, ar med\u017eiagos yra per lipnios (didelis COF) ar per slid\u017eios (ma\u017eas COF), kurios gali tur\u0117ti \u012ftakos gaminio veikimui.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Nulupimo j\u0117gos testas<\/h3>\n\n\n\n<p>The <strong>lupimo j\u0117gos bandymas<\/strong> yra vienodai svarbus tokioms reikm\u0117ms kaip pakuo\u010di\u0173 plombos, lipnios etiket\u0117s ir medicinos prietaisai. Jis matuoja j\u0117g\u0105, reikaling\u0105 vienam sluoksniui nulupti nuo kito. Procesas apima nedidel\u0119 j\u0117g\u0105, kad nupl\u0117\u0161t\u0173 med\u017eiagos sluoksn\u012f (pvz., lipni\u0105 juostel\u0119 ar apsaugin\u0119 pl\u0117vel\u0119) nuo pagrindo ir fiksuojama j\u0117ga per vis\u0105 atskyrimo trukm\u0119.<\/p>\n\n\n\n<p>The <strong>Trinties lupimo testeris<\/strong> leid\u017eia tiksliai valdyti bandymo parametrus, tokius kaip pradin\u0117 ir uodegos dalys, kurios turi \u012ftakos lupimo stiprumui. Galimyb\u0117 analizuoti \u0161i\u0173 sekcij\u0173 lupimo j\u0117g\u0105 padeda gamintojams optimizuoti savo klij\u0173 gaminius, kad b\u016bt\u0173 patogu juos naudoti, i\u0161laikant saugius sukibimus.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Atitikimas tarptautiniams standartams<\/h2>\n\n\n\n<p>The <strong>Trinties lupimo testeris<\/strong> atitinka daugyb\u0119 tarptautini\u0173 standart\u0173, u\u017etikrinant, kad jis atitikt\u0173 \u012fvairi\u0173 pramon\u0117s \u0161ak\u0173 reikalavimus:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>ISO 8295<\/strong>: \u0160is standartas nurodo plastikini\u0173 pl\u0117veli\u0173 ir lak\u0161t\u0173 COF nustatymo metodus. Laikydamiesi \u0161io standarto, gamintojai gali garantuoti, kad j\u0173 gaminiai atitinka pasaulinius pakavimo med\u017eiag\u0173 reikalavimus.<\/li>\n\n\n\n<li><strong>ASTM D1894<\/strong>: \u0160iame pla\u010diai naudojamame standarte apra\u0161omos plastikini\u0173 pl\u0117veli\u0173 ir padengt\u0173 substrat\u0173 COF testavimo proced\u016bros, kurios yra labai svarbus pakuo\u010di\u0173 pramon\u0117s aspektas.<\/li>\n\n\n\n<li><strong>TAPPI T816<\/strong>: Pateikiamas popieriaus ir kartono trinties savybi\u0173 matavimo metodas, u\u017etikrinantis, kad \u0161ios med\u017eiagos veiks taip, kaip tik\u0117tasi tvarkant ir apdorojant.<\/li>\n\n\n\n<li><strong>ISO 8510-2<\/strong>: Taiko klij\u0173 nulupimo sukibimo bandymus. \u0160is standartas u\u017etikrina, kad klijai i\u0161laikyt\u0173 pastov\u0173 nusilupimo stiprum\u0105, o tai labai svarbu naudojant medicinines juostas ir pakuo\u010di\u0173 sandariklius.<\/li>\n\n\n\n<li><strong>ASTM D4917<\/strong>: \u0160iame standarte pagrindinis d\u0117mesys skiriamas audini\u0173 trinties savyb\u0117ms, tod\u0117l tekstil\u0117s pramon\u0117s gamintojams suteikiami patikimi bandymo metodai.<\/li>\n\n\n\n<li><strong>ASTM D3330<\/strong>: Nurodo sl\u0117giui jautri\u0173 juost\u0173 nulupimo sukibimo bandymo metodus, padedan\u010dius gamintojams u\u017etikrinti, kad juostas b\u016bt\u0173 galima nuimti nepa\u017eeid\u017eiant pavir\u0161i\u0173 ir nepaliekant liku\u010di\u0173.<\/li>\n\n\n\n<li><strong>TAPPI T549<\/strong>: I\u0161samios atpalaiduojam\u0173j\u0173 \u012fd\u0117kl\u0173 ir klij\u0173 gamini\u0173 nulupimo sukibimo bandymas u\u017etikrina, kad \u0161ios med\u017eiagos atitikt\u0173 pakuot\u0117s ir \u017eenklinimo kokyb\u0117s l\u016bkes\u010dius.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Technin\u0117s specifikacijos<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>J\u0117gos diapazonas<\/td><td>5N, 10N arba 30N (arba kiti)<\/td><\/tr><tr><td>Tikslumas<\/td><td>0,5 FS<\/td><\/tr><tr><td>Rog\u0117s<\/td><td>200\u00b11g (arba pagal poreik\u012f)<\/td><\/tr><tr><td>Insultas<\/td><td>500 mm<\/td><\/tr><tr><td>Bandymo greitis<\/td><td>1 ~ 500 mm\/min<\/td><\/tr><tr><td>Galia<\/td><td>110~220V 50\/60Hz<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Kod\u0117l verta rinktis Cell Instruments trinties ir lupimo tester\u012f?<\/h2>\n\n\n\n<p>The <strong>Trinties lupimo testeris<\/strong> i\u0161siskiria savo universalumu, tikslumu ir atitikimu tarptautiniams standartams. Nesvarbu, ar bandoma trint\u012f, ar lupimo stiprum\u0105, \u0161is testeris gamintojams pateikia patikimus duomenis, kad pagerint\u0173 gaminio kokyb\u0119 ir u\u017etikrint\u0173 pramon\u0117s atitikt\u012f.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">DUK<\/h2>\n\n\n\n<p><strong>1 klausimas: kuo skiriasi statinis ir kinetinis COF?<\/strong><br>\n<strong>A<\/strong>: Statinis COF matuoja pasiprie\u0161inim\u0105, kai dvi med\u017eiagos yra ramyb\u0117s b\u016bsenoje, o kinetinis COF matuoja pasiprie\u0161inim\u0105 joms judant. Abu yra svarb\u016bs norint suprasti med\u017eiag\u0173 s\u0105veik\u0105 \u012fvairiais naudojimo etapais.<\/p>\n\n\n\n<p><strong>2 klausimas: kokias med\u017eiagas galima i\u0161bandyti naudojant trinties lupimo tester\u012f?<\/strong><br>\n<strong>A<\/strong>: Testeris gali dirbti su \u012fvairiomis med\u017eiagomis, \u012fskaitant plastikines pl\u0117veles, popieri\u0173, audinius, lipnias juostas ir kt., tod\u0117l jis tinkamas tokioms pramon\u0117s \u0161akoms kaip pakavimas, tekstil\u0117 ir medicinos prietaisai.<\/p>\n\n\n\n<p><strong>3 klausimas: kaip veikia lipni\u0173 produkt\u0173 lupimo testas?<\/strong><br>\n<strong>A<\/strong>: Nulupimo bandymas matuoja j\u0117g\u0105, reikaling\u0105 dviem suri\u0161tiems sluoksniams atskirti. Tai padeda nustatyti sukibimo stiprum\u0105 ir u\u017etikrina, kad gaminius b\u016bt\u0173 galima lengvai nulupti, nepa\u017eeid\u017eiant apatinio pavir\u0161iaus.<\/p>\n\n\n\n<p><strong>4 klausimas. Kokius pagrindinius standartus atitinka testeris?<\/strong><br> <strong>A<\/strong>: Testeris atitinka pagrindinius standartus, pavyzd\u017eiui, ISO 8295 (plastikin\u0117s pl\u0117vel\u0117s), <a href=\"https:\/\/www.iso.org\/standard\/20760.html\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">ASTM D1894<\/a> (plastikini\u0173 substrat\u0173 COF), TAPPI T816 (trintis kartone) ir ASTM D3330 (lipnios juostos atpl\u0117\u0161imo stiprumas) ir kt.<\/p>\n\n\n\n<p><strong>5 klausimas: Ar trinties lupimo testeris gali b\u016bti pritaikytas konkretiems poreikiams?<\/strong><br> <strong>A<\/strong>: Taip, \u012frenginys gali b\u016bti pritaikytas \u012fvairiems rogi\u0173 svoriams, j\u0117gos diapazonams ir bandymo grei\u010diams, kad atitikt\u0173 konkre\u010dius bandymo reikalavimus, tod\u0117l jis puikiai pritaikomas \u012fvairioms reikm\u0117ms.<\/p>","protected":false},"excerpt":{"rendered":"<p>Frikcinio pl\u0117\u0161ymo testeris yra pa\u017eangus prietaisas, skirtas dviem svarbiausioms med\u017eiag\u0173 bandym\u0173 savyb\u0117ms: trinties koeficientui (COF) ir pl\u0117\u0161imo j\u0117gai \u012fvertinti.<\/p>","protected":false},"featured_media":4910,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"product-category":[441,461,534,535,462,454,434,464,536,438,495,444,465,537,466],"product-tag":[],"class_list":["post-9561","products","type-products","status-publish","has-post-thumbnail","hentry","product-category-astm-standard","product-category-astm-d1894","product-category-astm-d3330","product-category-astm-d4917","product-category-coefficient-of-friction-tester","product-category-custom-lab-testing-instruments-manufacturer","product-category-iso","product-category-iso-8295","product-category-iso-8510-2","product-category-medical-and-pharmaceutical-testing","product-category-pharmaceutical-testing","product-category-plastic-testing","product-category-tappi","product-category-tappi-t549","product-category-tappi-t816"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/products\/9561","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/types\/products"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/media\/4910"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/media?parent=9561"}],"wp:term":[{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/product-category?post=9561"},{"taxonomy":"product-tag","embeddable":true,"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/product-tag?post=9561"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}