{"id":9579,"date":"2026-02-02T14:53:24","date_gmt":"2026-02-02T06:53:24","guid":{"rendered":"https:\/\/www.packqc.com\/products\/needle-penetration-and-drag-force-testing-machine-iso-7864\/"},"modified":"2026-04-16T10:30:21","modified_gmt":"2026-04-16T02:30:21","slug":"needle-penetration-and-drag-force-testing-machine-iso-7864","status":"publish","type":"products","link":"https:\/\/www.packqc.com\/lt\/products\/needle-penetration-and-drag-force-testing-machine-iso-7864\/","title":{"rendered":"NPD-01 adatos \u012fsiskverbimo ir tempimo j\u0117gos testeris"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Adatos \u012fsiskverbimo ir tempimo j\u0117gos tikrinimo ma\u0161ina<\/h2>\n\n\n\n<p>The <strong>Adatos \u012fsiskverbimo ir tempimo j\u0117gos tikrinimo ma\u0161ina<\/strong>&nbsp;(NPD-01) yra labai specializuotas prietaisas, skirtas matuoti j\u0117gas, susijusias su adatos \u012fsiskverbimu ir pasiprie\u0161inimu naudojimo metu. Matuojant tiek <strong>\u012fsiskverbimo j\u0117ga<\/strong> ir <strong>tempimo j\u0117ga<\/strong> adatos poveik\u012f, \u0161is aparatas padeda gamintojams patvirtinti poodini\u0173 adat\u0173, lancet\u0173 ir kit\u0173 adatini\u0173 medicinos prietais\u0173 veikim\u0105. \u0160is prietaisas atlieka svarb\u0173 vaidmen\u012f u\u017etikrinant atitikt\u012f tarptautiniams standartams, pvz. <a href=\"https:\/\/www.packqc.com\/lt\/product-category\/iso\/iso-7864\/\" target=\"_blank\" rel=\"noopener\"><strong style=\"font-style: inherit; text-align: var(--text-align); background-color: var(--ast-global-color-4); color: var(--ast-global-color-3);\">ISO 7864<\/strong><\/a>, kuriame nustatomos medicinos reikm\u0117ms naudojam\u0173 adat\u0173 veikimo tikrinimo gair\u0117s.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Prasiskverbimo j\u0117gos testo taikymas<\/h2>\n\n\n\n<p>The <strong>Adatos \u012fsiskverbimo ir tempimo j\u0117gos tikrinimo ma\u0161ina<\/strong>&nbsp;yra naudojamas \u012fvairiose srityse, ypa\u010d pramon\u0117s \u0161akose, kur adat\u0173 gamini\u0173 kokyb\u0117 yra svarbiausia:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Medicinos prietais\u0173 gamyba<\/strong>: Itin svarbu, kad poodini\u0173 adat\u0173, lancet\u0173 ir kit\u0173 adat\u0173 gamintojams b\u016bt\u0173 u\u017etikrinta, jog j\u0173 gaminiai atitikt\u0173 veikimo specifikacijas, \u012fskaitant lengv\u0105 ir patogum\u0105 \u012fsiskverbim\u0105.<\/li>\n\n\n\n<li><strong>Farmacijos \u012fmon\u0117s<\/strong>: Labai svarbu i\u0161bandyti adatas, naudojamas vaistams tiekti, siekiant u\u017etikrinti, kad jos skland\u017eiai, nuosekliai \u012fsiskverbt\u0173 ir sukelt\u0173 minimal\u0173 diskomfort\u0105 pacientams.<\/li>\n\n\n\n<li><strong>Tyrimai ir pl\u0117tra<\/strong>: Tyr\u0117jai, dirbantys su naujomis adat\u0173 technologijomis, gali naudoti \u0161i\u0105 bandymo ma\u0161in\u0105, kad tiksliai sureguliuot\u0173 savo dizain\u0105 ir u\u017etikrint\u0173 optimali\u0105 \u012fsiskverbimo j\u0117g\u0105 ir atsparum\u0105 tempimui.<\/li>\n\n\n\n<li><strong>Teis\u0117s akt\u0173 laikymasis<\/strong>: <strong>prasiskverbimo j\u0117gos bandymas<\/strong> yra svarbi reguliavimo reikalavim\u0173 dalis, \u012fskaitant nurodytus <strong>ISO 7864<\/strong> ir <strong>ISO 7864 D priedas<\/strong>, adatoms ir medicinos prietaisams.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Adatos \u012fsiskverbimo ir tempimo j\u0117gos bandymo b\u016btinyb\u0117<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Komfortas ir saugumas<\/strong>: Adatos, kurioms prasiskverbti reikia per daug j\u0117gos arba kurias sunku manevruoti, pacientams gali sukelti nereikaling\u0105 skausm\u0105 ir diskomfort\u0105. I\u0161matavus <strong>\u012fsiskverbimo j\u0117ga<\/strong> ir <strong>tempimo j\u0117ga<\/strong>, gamintojai gali optimizuoti adatos dizain\u0105, kad suma\u017eint\u0173 skausm\u0105 injekcij\u0173 metu.<\/li>\n\n\n\n<li><strong>Teis\u0117s akt\u0173 laikymasis<\/strong>: Medicinos prietais\u0173 gamintojai turi u\u017etikrinti, kad j\u0173 gaminiai atitikt\u0173 grie\u017etus reikalavimus, nustatytus tarptautiniuose standartuose, pvz <strong>ISO 7864<\/strong>. \u0160ie standartai apibr\u0117\u017eia priimtinas j\u0117gos vertes, kuri\u0173 reikia laikytis, kad adatos b\u016bt\u0173 laikomos saugiomis ir veiksmingomis.<\/li>\n\n\n\n<li><strong>Klinikinio naudojimo efektyvumo prognozavimas<\/strong>: Adatos turi ne tik prasiskverbti \u012f audin\u012f, bet ir skland\u017eiai jud\u0117ti \u012fd\u0117jus. Bandymas abu <strong>tempimo j\u0117ga<\/strong> ir <strong>\u012fsiskverbimo j\u0117ga<\/strong> u\u017etikrina optimal\u0173 adatos veikim\u0105 injekcij\u0173 metu, pagerindama bendr\u0105 paciento prie\u017ei\u016br\u0105 ir suma\u017eindama komplikacij\u0173 skai\u010di\u0173.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">Adatos prasiskverbimo bandymo principas<\/h2>\n\n\n\n<p>The <strong>Adatos \u012fsiskverbimo ir tempimo j\u0117gos tikrinimo ma\u0161ina<\/strong>&nbsp;veikia tiksliai ir pakartojamu procesu, kuris matuoja j\u0117g\u0105, susijusi\u0105 su adatos \u012fvedimu. \u0160tai kaip tai veikia:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Adatos \u012fd\u0117jimo s\u0105ranka<\/strong>: <strong>bandymo adata<\/strong> \u012fterpiamas \u012f substrat\u0105 naudojant vyri\u0161k\u0105 luer k\u016bg\u012f, kuris jungiasi prie <strong>apkrovos elementas<\/strong>. Adata yra i\u0161d\u0117styta taip, kad ji jud\u0117t\u0173 per od\u0105 ar kitus audinius imituojan\u010di\u0105 med\u017eiag\u0105.<\/li>\n\n\n\n<li><strong>Prasiskverbimo j\u0117gos matavimas<\/strong>: Kai adata \u012fstumiama \u012f med\u017eiag\u0105, <strong>apkrovos elementas<\/strong> nuolat matuoja \u012fki\u0161imui reikaling\u0105 j\u0117g\u0105. \u0160is matavimas bandymo metu registruojamas \u012fvairiame gylyje.<\/li>\n\n\n\n<li><strong>Vilkimo j\u0117gos \u012fvertinimas<\/strong>: Po pradinio \u012fsiskverbimo ma\u0161ina \u012fvertina <strong>tempimo j\u0117ga<\/strong>\u2014 pasiprie\u0161inimas, atsirandantis adatai judant per med\u017eiag\u0105. Tai yra labai svarbus \u017eingsnis, nes jis suteikia informacijos apie adatos veikim\u0105 realaus pasaulio klinikin\u0117se programose.<\/li>\n\n\n\n<li><strong>Duomen\u0173 rinkimas<\/strong>: surinkti duomenys, \u012fskaitant abu <strong>pradin\u0117 \u012fsiskverbimo j\u0117ga<\/strong> ir <strong>tempimo j\u0117ga<\/strong> vert\u0117s, rodomos \u012frenginio patogiai <strong>HMI jutiklinis ekranas<\/strong> ir automati\u0161kai atspausdinamas per integruot\u0105 <strong>mikrospausdintuvas<\/strong> apskaitos tvarkymui.<\/li>\n<\/ol>\n\n\n\n<p>\u0160is procesas u\u017etikrina, kad tiek \u012fsiskverbimo, tiek pasiprie\u0161inimo j\u0117gos b\u016bt\u0173 tiksliai i\u0161matuotos, gamintojams suteikiant duomenis, reikalingus j\u0173 adat\u0173 kokybei ir veikimui \u012fvertinti.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Technin\u0117 specifikacija<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Loadcell<\/td><td>50N (arba pagal poreik\u012f)<\/td><\/tr><tr><td>Bandymo greitis<\/td><td>1 ~ 500 mm\/min<\/td><\/tr><tr><td>J\u0117gos tikslumas<\/td><td>0.5% FS<\/td><\/tr><tr><td>Tikslumas<\/td><td>0,01 mm<\/td><\/tr><tr><td>Galia<\/td><td>110-220V<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Technin\u0117 savyb\u0117<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><b>\u0160viestuvai<\/b>: apima kelis tvirtinimo elementus, skirtus skirtingiems adatos bandymo scenarijams, \u012fskaitant pasiprie\u0161inimo j\u0117gos bandym\u0105 ir j\u0117gos bandymus \u017eemyn<\/li>\n\n\n\n<li><b>Didelis tikslumas<\/b>: 0,01 mm tikslumu ir 0,51 TP3T j\u0117gos tikslumu ma\u0161ina u\u017etikrina tikslius ir patikimus matavimus.<\/li>\n\n\n\n<li><b>Universalumas<\/b>: D\u0117l reguliuojamo bandymo grei\u010dio ir pritaikomos apkrovos element\u0173 talpos \u0161i ma\u0161ina tinka \u012fvairiems adat\u0173 tipams ir bandymo reikalavimams.<\/li>\n\n\n\n<li><b>Naudojimo paprastumas<\/b>: HMI jutiklinis ekranas supaprastina bandymo s\u0105rank\u0105 ir veikim\u0105, o integruotas mikrospausdintuvas u\u017etikrina efektyv\u0173 rezultat\u0173 dokumentavim\u0105.<\/li>\n\n\n\n<li><b>Automatinis testavimas<\/b>: Automatin\u0117 gr\u0105\u017einimo funkcija ir apsauga nuo perkrovos padidina saugum\u0105 ir daro testavimo proces\u0105 efektyvesn\u012f.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Konfig\u016bracijos ir priedai<\/h2>\n\n\n\n<p>The <strong>Adatos \u012fsiskverbimo ir tempimo j\u0117gos tikrinimo ma\u0161ina<\/strong>&nbsp;tiekiamas su visu pried\u0173 rinkiniu, skirtu \u012fvairioms testavimo programoms:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Pagrindin\u0117 ma\u0161ina<\/strong>: pagrindinis bandymo blokas, sukurtas tikslumui ir ilgaam\u017ei\u0161kumui.<\/li>\n\n\n\n<li><strong>Substrato laikiklis<\/strong>: Bandymo metu i\u0161laiko med\u017eiag\u0105 vietoje, u\u017etikrinant tikslius matavimus.<\/li>\n\n\n\n<li><strong>Maitinimo laidas<\/strong>: Suderinamas su pla\u010diu \u012ftampos diapazonu (110\u2013220 V), skirtas naudoti visame pasaulyje.<\/li>\n\n\n\n<li><strong>Saugiklis<\/strong>: Apsaugo \u012frengin\u012f nuo elektros perkrov\u0173.<\/li>\n\n\n\n<li><strong>Adat\u0173 tvirtinimo detal\u0117s<\/strong>: Galima \u012fsigyti \u012fvairi\u0173 tvirtinimo detali\u0173, skirt\u0173 \u012fvairi\u0173 tip\u0173 adatoms i\u0161bandyti, u\u017etikrinant \u012fvairiapusi\u0161kum\u0105 i\u0161bandant skirting\u0173 dizain\u0173 ir dyd\u017ei\u0173 adatas.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Su adatos prasiskverbimo bandymo metodu susij\u0119s standartas<\/h2>\n\n\n\n<p>The <strong>Adatos \u012fsiskverbimo ir tempimo j\u0117gos tikrinimo ma\u0161ina<\/strong>&nbsp;sukurtas taip, kad atitikt\u0173 tarptautinius standartus, \u012fskaitant:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><a href=\"https:\/\/www.packqc.com\/lt\/standard\/iso-7864\/\" target=\"_blank\" data-type=\"standard\" data-id=\"9833\" rel=\"noreferrer noopener nofollow\"><strong style=\"font-style: inherit; text-align: var(--text-align); background-color: var(--ast-global-color-4); color: var(--ast-global-color-3);\">ISO 7864<\/strong><\/a><\/h3>\n\n\n\n<p>Sterilios vienkartin\u0117s poodin\u0117s adatos. Reikalavimai ir bandymo metodai<\/p>\n\n\n\n<p><strong style=\"font-style: inherit; text-align: var(--text-align); background-color: var(--ast-global-color-4); color: var(--ast-global-color-3);\">D priedas \u2013<\/strong>&nbsp;Bandymo metodas adat\u0173 \u012fsiskverbimo ir pasiprie\u0161inimo j\u0117gai matuoti<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Kitas standartas<\/h3>\n\n\n\n<p><strong style=\"font-style: inherit; text-align: var(--text-align); color: var(--ast-global-color-3); background-color: var(--ast-global-color-4);\">GB 15811<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pagalba ir mokymas<\/h2>\n\n\n\n<p>\u201eCell Instruments\u201c si\u016blo visapusi\u0161kas palaikymo ir mokymo paslaugas, kurios pad\u0117s jums i\u0161naudoti visas savo galimybes <strong>Adatos \u012fsiskverbimo ir tempimo j\u0117gos tikrinimo ma\u0161ina<\/strong>e:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Operatori\u0173 mokymas<\/strong>: I\u0161samios mokymo programos, u\u017etikrinan\u010dios, kad j\u016bs\u0173 komanda gal\u0117t\u0173 efektyviai naudotis ma\u0161ina.<\/li>\n\n\n\n<li><strong>Technin\u0117 pagalba<\/strong>: nuolatinis trik\u010di\u0173 diagnostikos, kalibravimo ir prie\u017ei\u016bros palaikymas.<\/li>\n\n\n\n<li><strong>Kalibravimo paslaugos<\/strong>: reguliarios kalibravimo paslaugos, kad b\u016bt\u0173 i\u0161laikytas ma\u0161inos tikslumas ir patikimumas.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">DUK<\/h2>\n\n\n\n<p><strong>1 klausimas: kaip adatos \u012fsiskverbimo ir pasiprie\u0161inimo j\u0117gos testavimo aparatas matuoja pasiprie\u0161inimo j\u0117g\u0105?<\/strong><br>A1: Ma\u0161ina matuoja pasiprie\u0161inimo j\u0117g\u0105 registruodama pasiprie\u0161inim\u0105, susijus\u012f su adata judant per med\u017eiag\u0105 po pradinio \u012fsiskverbimo.<\/p>\n\n\n\n<p><strong>2 klausimas: ar \u0161i ma\u0161ina gali b\u016bti naudojama kit\u0173 tip\u0173 adatoms i\u0161bandyti?<\/strong><br>A2: Taip, aparatas yra universalus ir gali b\u016bti naudojamas tikrinant \u012fvairias adatas, \u012fskaitant poodines adatas, lancetus ir \u0161virk\u0161tus.<\/p>\n\n\n\n<p><strong>3 klausimas: ar NPD-01 aparatas atitinka ISO 7864?<\/strong><br>A3: Taip, ma\u0161ina visi\u0161kai atitinka <strong><a href=\"https:\/\/www.iso.org\/standard\/60481.html\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">ISO 7864<\/a><\/strong> ir <strong>ISO 7864 D priedas<\/strong>, u\u017etikrinant, kad jis atitikt\u0173 b\u016btinus medicinos prietais\u0173 testavimo standartus.<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>By measuring both the penetration force and the drag force exerted by the needle, the machine helps manufacturers validate the performance of hypodermic needles, lancets, and other needle-based medical devices.<\/p>","protected":false},"featured_media":10238,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"product-category":[454,456,573,434,574,495,593],"product-tag":[],"class_list":["post-9579","products","type-products","status-publish","has-post-thumbnail","hentry","product-category-custom-lab-testing-instruments-manufacturer","product-category-gb","product-category-gb-15811","product-category-iso","product-category-iso-7864","product-category-pharmaceutical-testing","product-category-syringe-testing"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/products\/9579","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/types\/products"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/media\/10238"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/media?parent=9579"}],"wp:term":[{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/product-category?post=9579"},{"taxonomy":"product-tag","embeddable":true,"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/product-tag?post=9579"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}