{"id":9825,"date":"2026-02-24T15:11:44","date_gmt":"2026-02-24T07:11:44","guid":{"rendered":"https:\/\/www.packqc.com\/standard\/iso-9626\/"},"modified":"2026-04-16T09:54:22","modified_gmt":"2026-04-16T01:54:22","slug":"iso-9626","status":"publish","type":"standard","link":"https:\/\/www.packqc.com\/lt\/standard\/iso-9626\/","title":{"rendered":"ISO 9626"},"content":{"rendered":"<p><\/p>\n\n\n\n<h1 class=\"wp-block-heading\">ISO 9626<\/h1>\n\n\n\n<h2 class=\"wp-block-heading\">Kas yra ISO 9626?<\/h2>\n\n\n\n<p>Jame pateikiamos standartizuotos ner\u016bdijan\u010diojo plieno vamzdeli\u0173, naudojam\u0173 medicinin\u0117ms adatoms gaminti, specifikacijos nuo 3,4 mm (10 storio) iki 0,18 mm (34 storio). Standartas taikomas tik standiesiems vamzdeliams, i\u0161skyrus lanks\u010diuosius variantus d\u0117l skirting\u0173 mechanini\u0173 savybi\u0173.<\/p>\n\n\n\n<p>Pagrindin\u0117s sritys, kurioms taikomas ISO 9626, yra \u0161ios:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><b>Matmen\u0173 nuokrypiai<\/b> i\u0161 ner\u016bdijan\u010dio plieno adatini\u0173 vamzdeli\u0173<\/li>\n\n\n\n<li>Mechanin\u0117s savyb\u0117s, pvz. <b>standumas ir atsparumas l\u016b\u017eiams<\/b><\/li>\n\n\n\n<li><b>Atsparumas korozijai<\/b> imituojamomis fiziologin\u0117mis s\u0105lygomis<\/li>\n\n\n\n<li>Biologinio suderinamumo tyrimams skirt\u0173 ekstrakt\u0173 paruo\u0161imas ir \u012fvertinimas<\/li>\n<\/ul>\n\n\n\n<p>\u0160is standartas yra labai svarbus gamintojams, gaminantiems adatas injekcijoms, skys\u010di\u0173 m\u0117giniams imti ir kitoms medicinin\u0117ms reikm\u0117ms. Jo laikymasis u\u017etikrina veikimo nuoseklum\u0105, pacient\u0173 saug\u0105 ir atitikt\u012f pasaulini\u0173 reguliavimo institucij\u0173 reikalavimams.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u0160virk\u0161to adatos bandymas pagal ISO 9626<\/h2>\n\n\n\n<p>ISO 9626 apra\u0161o kelet\u0105 svarbi\u0173 \u0161virk\u0161t\u0173 adat\u0173 bandymo proced\u016br\u0173, kuriomis patvirtinamas mechaninis adat\u0173 vamzdeli\u0173 vientisumas ir ilgaam\u017ei\u0161kumas:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Injekcin\u0117s adatos standumo bandymas<\/h3>\n\n\n\n<p>\u0160iuo bandymu \u012fvertinamas adatos vamzdelio standumas veikiant kontroliuojamai apkrovai. Atliekant \u0161i\u0105 proced\u016br\u0105 atliekami \u0161ie veiksmai:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Vamzd\u017eio laikymas ant tarpatramio, kur\u012f lemia jo gabaritas<\/li>\n\n\n\n<li>J\u0117gos veikimas \u017eemyn per tam tikros geometrijos st\u016bmokl\u012f<\/li>\n\n\n\n<li>Deformacijos centre matavimas siekiant \u012fvertinti standum\u0105<\/li>\n<\/ul>\n\n\n\n<p>D\u0117l per didelio lankstumo gali b\u016bti blogai valdomas arba netiksliai \u012f\u0161virk\u0161\u010diamas. Gamintojai turi u\u017etikrinti, kad adata i\u0161laikyt\u0173 mechanin\u012f stabilum\u0105 numatytomis klinikinio naudojimo s\u0105lygomis.<\/p>\n\n\n\n<p>\u2019Cell Instruments\" TS-01 adatini\u0173 vamzd\u017ei\u0173 standumo testeris yra optimizuotas \u0161iam tikslui. Jis si\u016blo:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u00b10,1 N j\u0117gos tikslumas<\/li>\n\n\n\n<li>Mikron\u0173 lygio nuokrypio matavimas<\/li>\n\n\n\n<li>Pritaikomi diapazono nustatymai pagal matuoklio specifikacij\u0105<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Adatos atsparumo pertraukimui bandymas<\/h3>\n\n\n\n<p>Atsparumas l\u016b\u017eiams yra labai svarbus, kad vamzd\u017eiai nesugest\u0173 naudojimo metu. ISO 9626 numato ciklinio lenkimo bandym\u0105, kurio metu vamzd\u017eiai pakaitomis lenkiami iki 20 kart\u0173 tam tikru kampu:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u012eprast\u0173 sieneli\u0173 vamzd\u017eiai: (25 \u00b11)\u00b0<\/li>\n\n\n\n<li>Plonasieniai vamzd\u017eiai: (20 \u00b11)\u00b0<\/li>\n\n\n\n<li>Ypa\u010d plonos \/ itin plonos sienel\u0117s: (15 \u00b11)\u00b0<\/li>\n<\/ul>\n\n\n\n<p>\u0160is bandymas padeda \u012fvertinti atsparum\u0105 nuovargiui esant pakartotinei apkrovai. Matomas l\u016b\u017eis rodo gedim\u0105.<\/p>\n\n\n\n<p>Cell Instruments\u2019 NTT-01 adatini\u0173 vamzdeli\u0173 atsparumo tr\u016bkimui testeris atlieka \u0161\u012f bandym\u0105:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>programuojami lenkimo kampai ir ciklai<\/li>\n\n\n\n<li>Vizualin\u0117s patikros \u012ftaisai<\/li>\n\n\n\n<li>Reguliuojamas \u012fvairi\u0173 skersmen\u0173 vamzd\u017ei\u0173 u\u017espaudimas<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Atsparumo korozijai vertinimas<\/h3>\n\n\n\n<p>ISO 9626 standarto D priede aptariamas atsparumas korozijai, u\u017etikrinant, kad adatos nesugest\u0173 d\u0117l s\u0105ly\u010dio su k\u016bno skys\u010diais. Ner\u016bdijan\u010diojo plieno vamzdeliai turi b\u016bti atspar\u016bs \u012fdubimui ir r\u016bd\u017ei\u0173 susidarymui, panardinus juos \u012f tiriamuosius tirpalus, pavyzd\u017eiui, fiziologin\u012f tirpal\u0105.<\/p>\n\n\n\n<p>Nors ne visada privaloma, daugelis gamintoj\u0173, siekdami suma\u017einti rizik\u0105, atsparum\u0105 korozijai \u012ftraukia \u012f \u012fprastus \u0161virk\u0161t\u0173 adat\u0173 bandymus.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Papildomi ISO 9626 bandym\u0173 aspektai<\/h3>\n\n\n\n<p>Be pagrindini\u0173 mechanini\u0173 vertinim\u0173, ISO 9626 taip pat reikalauja:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Tiksl\u016bs matmen\u0173 matavimai<\/li>\n\n\n\n<li>Sien\u0173 tipo identifikavimas (RW, TW, ETW, UTW)<\/li>\n\n\n\n<li>Lydini\u0173 klasifikacija pagal ISO 15510 arba ASTM A959<\/li>\n\n\n\n<li>Bandym\u0173 dokumentai, \u012fskaitant matuoklio dyd\u012f, deformacijos vertes ir bandymo s\u0105lygas<\/li>\n<\/ul>\n\n\n\n<p>Tiksl\u016bs bandymai ne tik atitinka atitikties reikalavimus, bet ir didina gaminio patikimum\u0105 bei stiprina prek\u0117s \u017eenklo reputacij\u0105.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">ISO 9626 bandymas - b\u016btinas \u0161virk\u0161t\u0173 kokyb\u0117s kontrolei<\/h2>\n\n\n\n<p>Jei nesilaikoma ISO 9626 standart\u0173, gali b\u016bti:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Adatos sulenkimas arba l\u016b\u017eimas \u0161virk\u0161\u010diant<\/li>\n\n\n\n<li>Nenuoseklus skys\u010di\u0173 tiekimas<\/li>\n\n\n\n<li>Didesn\u0117 pacient\u0173 su\u017ealojimo rizika<\/li>\n\n\n\n<li>Reguliavimo reikalavim\u0173 nesilaikymas ir at\u0161aukimai<\/li>\n<\/ul>\n\n\n\n<p>Integruodami ISO 9626 standart\u0105 atitinkan\u010dius \u0161virk\u0161t\u0173 adat\u0173 bandymus, gamintojai ir kokyb\u0117s u\u017etikrinimo komandos:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Patvirtinkite mechanin\u012f atsparum\u0105 ir ilgaam\u017ei\u0161kum\u0105<\/li>\n\n\n\n<li>U\u017etikrinti suderinamum\u0105 su teis\u0117s akt\u0173 reikalavimais<\/li>\n\n\n\n<li>Suma\u017einti atsakomyb\u0119 ir produkt\u0173 gedim\u0173 skai\u010di\u0173<\/li>\n\n\n\n<li>Didinti klient\u0173 pasitik\u0117jim\u0105 ir pasitenkinim\u0105<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">ISO 9626 testavimo sprendimo pasirinkimas<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.packqc.com\/lt\/product\/syringe-tube-stiffness-tester\/\" target=\"_blank\"><img decoding=\"async\" src=\"https:\/\/www.packqc.com\/wp-content\/uploads\/2025\/05\/Syringe-Tube-Stiffness-Tester-ISO-9626-Annex-B.webp\" alt=\"TS-01 \u0161virk\u0161to vamzdelio standumo testeris - ISO 9626 B priedas\"\/><\/a><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\"><a href=\"https:\/\/www.packqc.com\/lt\/product\/syringe-tube-stiffness-tester\/\" target=\"_blank\">TS-01 \u0161virk\u0161to adatos standumo testeris<\/a><\/h3>\n\n\n\n<p>Norint tiksliai \u012fvertinti ner\u016bdijan\u010dio plieno adat\u0173 vamzdeli\u0173 standumo charakteristikas, kaip nurodyta ISO 9626 B priede, Cell Instruments \u0161virk\u0161t\u0173 adat\u0173 standumo testeris TS-01 yra patikimas ir labai tikslus sprendimas. \u0160is prietaisas u\u017etikrina nuosekl\u0173 j\u0117gos taikym\u0105 ir tiksl\u0173 vamzdeli\u0173 deformacijos matavim\u0105, pad\u0117damas gamintojams ir kokyb\u0117s kontrol\u0117s komandoms patenkinti teis\u0117s akt\u0173 reikalavimus atitinkan\u010dius l\u016bkes\u010dius, susijusius su \u0161virk\u0161t\u0173 adat\u0173 standumo bandymais.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.packqc.com\/lt\/product\/needle-toughness-tester\/\" target=\"_blank\"><img decoding=\"async\" src=\"https:\/\/www.packqc.com\/wp-content\/uploads\/2025\/04\/Needle-Toughness-Tester-ISO-9626-Breakage-Resistance-Test.webp\" alt=\"NTT-01 adatos kietumo testeris - ISO 9626 atsparumo l\u016b\u017eiui bandymas\"\/><\/a><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\"><a href=\"https:\/\/www.packqc.com\/lt\/product\/needle-toughness-tester\/\" target=\"_blank\">NTT-01 adatos atsparumo pertraukimui testeris<\/a><\/h3>\n\n\n\n<p>Medicinini\u0173 adatini\u0173 vamzdeli\u0173 mechaniniam patvarumui \u012fvertinti, veikiant kartotin\u0117ms lenkimo j\u0117goms pagal ISO 9626 C pried\u0105, NTT-01 adatos atsparumo l\u016b\u017eiui testeris yra labai svarbus \u012frankis. \u0160is testeris, sukurtas grie\u017etoms kokyb\u0117s u\u017etikrinimo s\u0105lygoms, imituoja realaus naudojimo s\u0105lygas ir pateikia tikslius duomenis apie vamzdeli\u0173 atsparum\u0105 ir strukt\u016brin\u012f vientisum\u0105 - tai labai svarbu siekiant i\u0161vengti adatos gedimo klinikinio naudojimo metu.<\/p>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\n\t\t\t\tSusisiekite su mumis Gaukite ISO 9626 testavimo sprendim\u0105\t\t\t\t<\/h2>\n\n\n\n<p><strong>ISO 9626<\/strong> atlieka pagrindin\u012f vaidmen\u012f <strong>\u0161virk\u0161t\u0173 adat\u0173 testavimas<\/strong> nustatydami kriterijus<strong> standumas, atsparumas l\u016b\u017eiams ir bendras strukt\u016brinis vientisumas.<\/strong> i\u0161 ner\u016bdijan\u010dio plieno adatinio vamzdelio. Atlikdami tikslius mechaninius vertinimus, gamintojai gali u\u017etikrinti, kad j\u0173 gaminiai atitikt\u0173 ir teis\u0117s akt\u0173 reikalavimus, ir funkcinius l\u016bkes\u010dius.<\/p>\n\n\n\n<p>\u2019Cell Instruments\" TS-01 ir NTT-01 testeriai - tai i\u0161samus, su ISO suderintas sprendimas, atitinkantis besikei\u010dian\u010dius medicinos prietais\u0173 kokyb\u0117s kontrol\u0117s reikalavimus. Investuokite \u012f geresn\u0119 atitikt\u012f reikalavimams, ma\u017eesn\u0119 rizik\u0105 ir auk\u0161\u010diausi\u0105 na\u0161um\u0105 su Cell Instruments kaip savo partneriu \u0161virk\u0161t\u0173 adat\u0173 testavimo srityje.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">DUK<\/h2>\n\n\n\n<p>1. Koks yra pagrindinis standaardo tikslas?<br>ISO 9626 apibr\u0117\u017eia kiet\u0173j\u0173 ner\u016bdijan\u010dio plieno adatini\u0173 vamzdeli\u0173, naudojam\u0173 medicinos prietaisuose, matmen\u0173 ir mechaninius reikalavimus, kad b\u016bt\u0173 u\u017etikrinta sauga ir veikimas.<\/p>\n\n\n\n<p>2. Kokius bandymus apima ISO 9626?<br>Atliekami injekcini\u0173 adat\u0173 standumo, atsparumo adatos l\u016b\u017eiui, atsparumo korozijai ir ekstrakto paruo\u0161imo biologinio suderinamumo vertinimui bandymai.<\/p>\n\n\n\n<p>3. Kokie yra RW, TW, ETW ir UTW vamzd\u017ei\u0173 tipai?<br>Tai sieneli\u0173 storio kategorijos: Nuo \u0161i\u0173 kategorij\u0173 priklauso bandymo parametrai ir lenkimo kampai.<\/p>\n\n\n\n<p>4. Kaip Cell Instruments \u012franga gali pad\u0117ti atlikti ISO 9626 bandymus?<br>\u2019Cell Instruments\" TS-01 ir NTT-01 u\u017etikrina tikslias, pakartojamas standumo ir atsparumo l\u016b\u017eiui bandymo s\u0105lygas, padedan\u010dias gamintojams laikytis <a href=\"https:\/\/www.iso.org\/standard\/60480.html\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">ISO 9626<\/a> standartus.<\/p>\n\n\n\n<p>5. Kod\u0117l svarbus adatos atsparumo nutr\u016bkimui bandymas?<br>Tai u\u017etikrina, kad adata nesul\u016b\u017et\u0173 veikiama streso, tod\u0117l i\u0161vengiama prietaiso gedimo ir paciento su\u017ealojimo.<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>ISO 9626 What is ISO 9626? It provides standardized specifications for stainless steel tubing used in the manufacture of medical needles, ranging from 3.4 mm (10 Gauge) down to 0.18 mm (34 Gauge). The standard applies only to rigid tubing, excluding flexible variants due to differing mechanical behaviors. Key areas covered by ISO 9626 include: [&hellip;]<\/p>","protected":false},"featured_media":5377,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"standard-category":[612],"class_list":["post-9825","standard","type-standard","status-publish","has-post-thumbnail","hentry","standard-category-iso"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/standard\/9825","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/standard"}],"about":[{"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/types\/standard"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/media\/5377"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/media?parent=9825"}],"wp:term":[{"taxonomy":"standard-category","embeddable":true,"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/standard-category?post=9825"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}