{"id":9826,"date":"2026-02-24T15:11:44","date_gmt":"2026-02-24T07:11:44","guid":{"rendered":"https:\/\/www.packqc.com\/standard\/astm-f1140-3\/"},"modified":"2026-04-16T09:53:22","modified_gmt":"2026-04-16T01:53:22","slug":"astm-f1140","status":"publish","type":"standard","link":"https:\/\/www.packqc.com\/lt\/standard\/astm-f1140\/","title":{"rendered":"ASTM F1140"},"content":{"rendered":"<h2 class=\"wp-block-heading\">ASTM F1140 standarto supratimas ir jo svarba<\/h2>\n\n\n\n<p><strong data-start=\"822\" data-end=\"836\">ASTM F1140<\/strong> apra\u0161yti bandym\u0173 metodai, kuriais imituojamos realaus pasaulio sl\u0117gio s\u0105lygos, siekiant nustatyti atsparum\u0105 gedimams. <strong data-start=\"943\" data-end=\"977\">nevar\u017eomos lanks\u010dios pakuot\u0117s<\/strong>. \u0160is standartas padeda gamintojams laikytis teis\u0117s akt\u0173 reikalavim\u0173 ir padeda nuolat gerinti kokyb\u0119.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Bandym\u0173 metodai pagal ASTM F1140<\/h2>\n\n\n\n<p>\u012e ASTM F1140 standart\u0105 \u012ftrauktos trys pagrindin\u0117s bandym\u0173 proced\u016bros, skirtos skirtingoms pakuo\u010di\u0173 gedimo charakteristikoms \u012fvertinti:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Sprogimo bandymas (A bandymo metodas)<\/h3>\n\n\n\n<p>\u0160iame <strong data-start=\"1277\" data-end=\"1302\">pakuo\u010di\u0173 sprogimo bandymai<\/strong> metodu, vidinis sl\u0117gis palaipsniui didinamas tol, kol paketas ply\u0161ta. Taip tiesiogiai i\u0161matuojamas <strong data-start=\"1407\" data-end=\"1427\">did\u017eiausias sl\u0117gis<\/strong> kur\u012f pakuot\u0117 gali atlaikyti iki gedimo, nurodant jos atsparum\u0105 ply\u0161imui.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><em data-start=\"1504\" data-end=\"1519\">Parai\u0161kos:<\/em> Idealiai tinka kokyb\u0117s kontrolei gamybos metu ir pakuo\u010di\u0173 vertinimui po sterilizacijos.<\/li>\n\n\n\n<li><em data-start=\"1609\" data-end=\"1621\">Proced\u016bra:<\/em> U\u017eplombuota arba atidaryta pakuot\u0117 \u012fdedama \u012f special\u0173 tester\u012f. Pradedamas sl\u0117gis ir palaikomas tol, kol matomas matomas ply\u0161imas arba sandariklio gedimas. U\u017era\u0161omas gedimo ta\u0161kas ir sl\u0117gio vert\u0117.<\/li>\n\n\n\n<li><em data-start=\"1820\" data-end=\"1832\">\u012eranga:<\/em> Reikalingas tikslus pneumatinis valdymas, sl\u0117gio steb\u0117jimas realiuoju laiku ir tikslus sl\u0117gio reguliatorius.<a href=\"https:\/\/www.packqc.com\/lt\/product-category\/astm-standard\/astm-f1140\/\"> <\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u0160liau\u017eimo bandymas (bandymo metodas B1)<\/h3>\n\n\n\n<p>\u0160iuo metodu tikrinamas paketo geb\u0117jimas i\u0161laikyti <strong data-start=\"2025\" data-end=\"2056\">nurodytas vidinis sl\u0117gis<\/strong> laikui b\u0117gant.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><em data-start=\"2071\" data-end=\"2086\">Parai\u0161kos:<\/em> Geriausiai tinka med\u017eiagoms, kurios gali sugesti d\u0117l ilgalaikio sl\u0117gio poveikio.<\/li>\n\n\n\n<li><em data-start=\"2166\" data-end=\"2178\">Proced\u016bra:<\/em> Pakuot\u0117 pripumpuojama iki nustatyto sl\u0117gio (paprastai 80% jos ply\u0161imo stiprumo) ir laikoma nustatyt\u0105 laik\u0105 - paprastai nuo 15 iki 30 sekund\u017ei\u0173. Steb\u0117tojai stebi, ar sandariklis nesideformuoja arba ar nei\u0161siskleid\u017eia.<\/li>\n\n\n\n<li><em data-start=\"2371\" data-end=\"2380\">Rezultatas:<\/em> Patenkinama\/nepatenkinama, atsi\u017evelgiant \u012f tai, ar paketas i\u0161laiko sl\u0117g\u012f be gedim\u0173.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u0160liau\u017eimas iki gedimo (B2 bandymo metodas)<\/h3>\n\n\n\n<p>\u0160i versija - tai \u0161liau\u017eimo bandymo prat\u0119simas, kurio metu palaikomas auk\u0161tas vidinis sl\u0117gis (paprastai 90% ply\u0161imo stiprio), kol paketas galiausiai sugenda.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><em data-start=\"2651\" data-end=\"2668\">Testo statistika:<\/em> Laikas iki gedimo.<\/li>\n\n\n\n<li><em data-start=\"2691\" data-end=\"2701\">Tikslas:<\/em> Vertinamas ilgalaikis sl\u0117gio ilgaam\u017ei\u0161kumas ir atsparumas laipsni\u0161kam gedimui.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">ASTM F1140 pakuot\u0117je ir kokyb\u0117s kontrol\u0117je<\/h2>\n\n\n\n<p>Suprasti <strong data-start=\"2861\" data-end=\"2891\">ASTM F1140 reik\u0161m\u0117<\/strong> padeda pakavimo in\u017einieriams ir kokyb\u0117s specialistams:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Imituoti realaus pasaulio sl\u0117gio svyravimus <strong data-start=\"2995\" data-end=\"3026\">transportavimas ir sterilizavimas<\/strong>.<\/li>\n\n\n\n<li>\u012evertinkite med\u017eiag\u0173 ar sandarikli\u0173 tr\u016bkumus \u012fvairiose pakuo\u010di\u0173 r\u016b\u0161yse.<\/li>\n\n\n\n<li>Palyginkite skirting\u0173 med\u017eiag\u0173 ar gamybos partij\u0173 na\u0161um\u0105.<\/li>\n\n\n\n<li>U\u017etikrinti <strong data-start=\"3160\" data-end=\"3191\">teigiamo sl\u0117gio nuot\u0117kio bandymas<\/strong> sterili\u0173 pakuo\u010di\u0173 eksploatacin\u0117s savyb\u0117s.<\/li>\n<\/ul>\n\n\n\n<p>Kiekvienas metodas suteikia unikali\u0105 informacij\u0105 apie tai, kaip pakuot\u0117 gali atlaikyti vidin\u012f sl\u0117g\u012f. Kartu jie sudaro tvirt\u0105 lanks\u010dios pakuot\u0117s patvirtinimo sistem\u0105.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">ASTM F1140 reikalavimai \u012frangai<\/h2>\n\n\n\n<p>Kad atitikt\u0173 ASTM F1140 standarto reikalavimus, bandym\u0173 sistema turi leisti:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Kontroliuojamas ir i\u0161matuojamas <strong data-start=\"3550\" data-end=\"3577\">vidinis sl\u0117gis<\/strong>.<\/li>\n\n\n\n<li>Greitas sl\u0117gio kritimo aptikimo reakcijos laikas.<\/li>\n\n\n\n<li>Parama <strong data-start=\"3644\" data-end=\"3679\">atvir\u0173 ir u\u017edar\u0173 pakuo\u010di\u0173 bandymai<\/strong>.<\/li>\n\n\n\n<li><span style=\"font-size: 1rem;\">Reguliuojamos bandym\u0173 konfig\u016bracijos (sl\u0117gio greitis, laikas, \u012f\u0117jimo ta\u0161kai).<\/span><\/li>\n<\/ul>\n\n\n\n<p>\"Cell Instruments\" si\u016blo sprendim\u0105, kuris atitinka visus \u0161iuos reikalavimus.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Geriausia praktika siekiant gauti tikslius sprogimo testo rezultatus<\/h2>\n\n\n\n<p>Kad u\u017etikrintum\u0117te savo <strong data-start=\"4590\" data-end=\"4610\">ASTM F1140 bandymai<\/strong>, vadovaukit\u0117s \u0161iomis rekomendacijomis:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"4645\" data-end=\"4666\">B\u016bkl\u0117s pavyzd\u017eiai<\/strong> pagal ASTM standartus (pvz., ASTM E171), kad b\u016bt\u0173 standartizuota temperat\u016bra ir dr\u0117gm\u0117.<\/li>\n\n\n\n<li>Bandym\u0173 metu venkite apriboti pakuot\u0119 - laikykite j\u0105 <strong data-start=\"4806\" data-end=\"4832\">nesuvar\u017eytos b\u016bkl\u0117s<\/strong>.<\/li>\n\n\n\n<li>Tinklalapiui <strong data-start=\"4840\" data-end=\"4859\">u\u017edari paketai<\/strong>, centre \u012fstatykite sl\u0117gio \u012fvesties \u012ftais\u0105 ir, jei reikia, sutvirtinkite j\u012f juosta.<\/li>\n\n\n\n<li>Kad rezultatai neb\u016bt\u0173 i\u0161kreipti, naudokite vienod\u0105 sl\u0117gio didinimo greit\u012f.<\/li>\n\n\n\n<li>Visada dokumentuokite pakuot\u0117s konfig\u016bracij\u0105, gedimo b\u016bd\u0105, sl\u0117gio rodmenis ir bet kokias anomalijas.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Taikymas \u012fvairiose pramon\u0117s \u0161akose<\/h2>\n\n\n\n<p><strong data-start=\"5148\" data-end=\"5162\">ASTM F1140<\/strong> taikoma \u012fvairiuose sektoriuose:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"5200\" data-end=\"5228\">Medicinos prietais\u0173 pakuot\u0117s<\/strong>: Sterilios barjerin\u0117s sistemos vientisumo u\u017etikrinimas.<\/li>\n\n\n\n<li><strong data-start=\"5275\" data-end=\"5303\">Farmacijos pakuot\u0117s<\/strong>: Patikrinti u\u017eplombuoto mai\u0161elio patvarum\u0105 po sterilizacijos.<\/li>\n\n\n\n<li><strong data-start=\"5362\" data-end=\"5391\">Maisto produkt\u0173 ir g\u0117rim\u0173 mai\u0161eliai<\/strong>: Atsparumo ply\u0161imui bandymas apdorojant dideliu sl\u0117giu.<\/li>\n\n\n\n<li><strong data-start=\"5450\" data-end=\"5468\">Vartojimo prek\u0117s<\/strong>: Lanks\u010dios pl\u0117vel\u0117s pakuo\u010di\u0173, naudojam\u0173 buitiniams produktams, patvirtinimas.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Cell Instruments LSST-01 ki\u0161en\u0117s sprogimo testeris<\/h2>\n\n\n\n<p>Gamintojams, ie\u0161kantiems tikslios, patikimos ir lengvai naudojamos \u012frangos, skirtas <strong data-start=\"3974\" data-end=\"4004\">LSST-01 mai\u0161elio sprogimo testeris<\/strong> i\u0161 Cell Instruments yra idealus pasirinkimas. Jis palaiko:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"4063\" data-end=\"4080\">Sprogimo bandymas<\/strong>, <strong data-start=\"4082\" data-end=\"4091\">\u0161liau\u017eti<\/strong>, ir <strong data-start=\"4097\" data-end=\"4117\">\u0161liau\u017eimas iki gedimo<\/strong> re\u017eimai visi\u0161kai atitinka <a href=\"https:\/\/www.astm.org\/f1140_f1140m-13r20e01.html\" target=\"_blank\" rel=\"noopener nofollow\">ASTM F1140<\/a>.<\/li>\n\n\n\n<li>Abu <strong data-start=\"4167\" data-end=\"4209\">atvir\u0173 ir u\u017edar\u0173 pakuo\u010di\u0173 konfig\u016bracijos<\/strong>.<\/li>\n\n\n\n<li>Tiksli sl\u0117gio kontrol\u0117, skaitmeninis steb\u0117jimas ir automatinis bandymo parametr\u0173 \u012fra\u0161ymas.<\/li>\n<\/ul>\n\n\n\n<p>D\u0117l intuityvios s\u0105sajos ir tvirtos konstrukcijos LSST-01 pagerina efektyvum\u0105 mokslini\u0173 tyrim\u0173 ir pl\u0117tros bei kokyb\u0117s u\u017etikrinimo laboratorijose tokiose pramon\u0117s \u0161akose kaip medicinos prietaisai, vaistai ir lanks\u010dios pakuot\u0117s.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\n\t\t\t\tSusisiekite su mumis Gaukite Rub testavimo sprendim\u0105\t\t\t\t<\/h2>\n\n\n\n<p>Visiems, dirbantiems <strong data-start=\"5577\" data-end=\"5615\">lanks\u010di\u0173 pakuo\u010di\u0173 kokyb\u0117s kontrol\u0117<\/strong>, <strong data-start=\"5617\" data-end=\"5631\">ASTM F1140<\/strong> pateikia moksli\u0161kai pagr\u012fst\u0105 po\u017ei\u016br\u012f \u012f pakuo\u010di\u0173 stiprumo ir ilgaam\u017ei\u0161kumo, veikiant vidiniam sl\u0117giui, vertinim\u0105. ASTM F1140 bandymai atliekami naudojant patikim\u0105 \u012frang\u0105, pvz. <strong style=\"font-size: 16px;\" data-start=\"5987\" data-end=\"6035\">Cell Instruments\u2019 LSST-01 ki\u0161en\u0117s sprogimo testeris<\/strong> pagerina j\u016bs\u0173 kokyb\u0117s u\u017etikrinimo proces\u0105 ir padeda nuolat tobul\u0117ti.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">DUK<\/h2>\n\n\n\n<p>K\u0105 tikrina ASTM F1140 standartas?<br>Pagal ASTM F1140 \u012fvertinamas nesuvar\u017eyt\u0173 pakuo\u010di\u0173 atsparumas vidiniam sl\u0117giui iki gedimo.<\/p>\n\n\n\n<p>Kuo skiriasi ply\u0161imo ir \u0161liau\u017eimo bandymai?<br>Atliekant tr\u016bkimo bandymus sl\u0117gis did\u0117ja iki gedimo, o atliekant \u0161liau\u017eimo bandymus laikui b\u0117gant palaikomas pastovus sl\u0117gis ir stebimas atsparumas.<\/p>\n\n\n\n<p>Ar ASTM F1140 tinka vis\u0173 tip\u0173 pakuot\u0117ms?<br>Jis pirmiausia naudojamas lanks\u010dioms pakuot\u0117ms. Stand\u017eioms pakuot\u0117ms reikia kitoki\u0173 bandym\u0173 metod\u0173.<\/p>\n\n\n\n<p>Ar galiu atlikti \u0161iuos bandymus su pakuot\u0117je esan\u010diu produktu arba be jo?<br>Taip. Bandymai gali b\u016bti atliekami su gaminio turiniu arba be jo, ta\u010diau konfig\u016bracija tur\u0117t\u0173 b\u016bti dokumentuojama.<\/p>","protected":false},"excerpt":{"rendered":"<p>ASTM F1140 standarto supratimas ir jo svarba ASTM F1140 standarte apra\u0161yti bandymo metodai, kuriais imituojamos realios sl\u0117gio s\u0105lygos, siekiant nustatyti nesuvar\u017eyt\u0173 lanks\u010di\u0173 pakuo\u010di\u0173 atsparum\u0105 gedimui. \u0160is standartas padeda gamintojams laikytis teis\u0117s akt\u0173 reikalavim\u0173 ir padeda nuolat gerinti kokyb\u0119. Bandym\u0173 metodai pagal ASTM F1140 ASTM F1140 apima tris pagrindines bandym\u0173 proced\u016bras, skirtas skirtingiems pakuo\u010di\u0173 gedimams vertinti.<\/p>","protected":false},"featured_media":5399,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"standard-category":[611],"class_list":["post-9826","standard","type-standard","status-publish","has-post-thumbnail","hentry","standard-category-astm"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/standard\/9826","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/standard"}],"about":[{"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/types\/standard"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/media\/5399"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/media?parent=9826"}],"wp:term":[{"taxonomy":"standard-category","embeddable":true,"href":"https:\/\/www.packqc.com\/lt\/wp-json\/wp\/v2\/standard-category?post=9826"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}