{"id":9553,"date":"2026-02-02T14:53:35","date_gmt":"2026-02-02T06:53:35","guid":{"rendered":"https:\/\/www.packqc.com\/products\/npt-01-needle-penetrability-tester\/"},"modified":"2026-04-27T15:47:02","modified_gmt":"2026-04-27T07:47:02","slug":"npt-01-needle-penetrability-tester","status":"publish","type":"products","link":"https:\/\/www.packqc.com\/lv\/products\/npt-01-needle-penetrability-tester\/","title":{"rendered":"NPT-01 adatas caurlaid\u012bbas testeris"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Farm\u0101cijas un medic\u012bnas ier\u012b\u010du nozar\u0113s vissvar\u012bg\u0101k\u0101 ir nodro\u0161in\u0101t z\u0101\u013cu ievad\u012b\u0161anas sist\u0113mu dro\u0161\u012bbu un efektivit\u0101ti. Viens no t\u0101 kritiskajiem aspektiem ir adatas caurlaid\u012bbas tests, kas analiz\u0113 sp\u0113ku, kas nepiecie\u0161ams, lai injekcijas adata iek\u013c\u016btu flakona aizb\u0101zn\u012b. \u0160is tests ir b\u016btisks, lai saglab\u0101tu z\u0101\u013cu iepakojuma integrit\u0101ti un uzticam\u012bbu, nodro\u0161inot, ka pacienti sa\u0146em z\u0101les dro\u0161i un efekt\u012bvi.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">I. Ievads adatas caurlaid\u012bbas test\u0101<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">1. Adatas caurlaid\u012bbas p\u0101rbaudes noz\u012bme<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Adatu caurlaid\u012bbas p\u0101rbaude ir \u013coti svar\u012bga, lai nov\u0113rt\u0113tu farmaceitiskaj\u0101 iepakojum\u0101 izmantoto flakonu aizb\u0101\u017e\u0146u darb\u012bbu. Tas nodro\u0161ina, ka adata var iek\u013c\u016bt aizb\u0101zn\u012b bez p\u0101rm\u0113r\u012bga sp\u0113ka, nov\u0113r\u0161ot adatas boj\u0101jumus vai z\u0101\u013cu pies\u0101r\u0146ojumu. \u0160is tests ir \u013coti svar\u012bgs, lai saglab\u0101tu injic\u0113jamo z\u0101\u013cu kvalit\u0101ti un dro\u0161\u012bbu.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2. Galvenie parametri<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>P\u0101rbaudes diapazons<\/td><td>0 ~ 200 N (vai p\u0113c vajadz\u012bbas)<\/td><\/tr><tr><td>Insults<\/td><td>200 mm (bez skavas)<\/td><\/tr><tr><td>\u0100trums<\/td><td>1 ~ 500 mm\/min (vai p\u0113c vajadz\u012bbas)<\/td><\/tr><tr><td>Nob\u012bdes precizit\u0101te<\/td><td>0,01 mm<\/td><\/tr><tr><td>Precizit\u0101te<\/td><td>0.5% FS<\/td><\/tr><tr><td>Izvade<\/td><td>Ekr\u0101ns, mikroprinteris, RS232 (p\u0113c izv\u0113les)<\/td><\/tr><tr><td>Jauda<\/td><td>110~ 220V 50\/60Hz<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.packqc.com\/lv\/products\/npt-01-needle-penetrability-tester\/\"><img decoding=\"async\" src=\"https:\/\/www.packqc.com\/wp-content\/uploads\/elementor\/thumbs\/Needle-Penetrability-Tester-for-Rubber-Stopper-ISO-8871-5-1-qqb7bxl9h3d566686odtgfyduz6nxnf2yd532cjaio.jpg\" alt=\"Adatas caurlaid\u012bbas testeris gumijas aizb\u0101znim ISO 8871-5 1\" title=\"Adatas caurlaid\u012bbas testeris gumijas aizb\u0101znim ISO 8871-5 1\"\/><\/a><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">II. Tehnisk\u0101s \u012bpa\u0161\u012bbas<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">1. PLC vad\u012bbas bloks un lietot\u0101jam draudz\u012bgs HMI sk\u0101rienekr\u0101ns<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Adatas caurlaid\u012bbas testeris ir apr\u012bkots ar PLC vad\u012bbas bloku un 7 collu HMI sk\u0101rienekr\u0101nu, nodro\u0161inot operatoriem intuit\u012bvu saskarni. \u0160\u012b iestat\u012b\u0161ana \u013cauj viegli konfigur\u0113t un p\u0101rraudz\u012bt testus, uzlabojot lietot\u0101ja pieredzi un efektivit\u0101ti.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2. Prec\u012bzijas lodveida skr\u016bve un pak\u0101pju motors<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Prec\u012bza lodveida skr\u016bve un pak\u0101pju motors nodro\u0161ina prec\u012bzus un konsekventus testus. \u0160\u012b kombin\u0101cija nodro\u0161ina prec\u012bzu adatas kust\u012bbas kontroli, k\u0101 rezult\u0101t\u0101 tiek ieg\u016bti uzticami un atk\u0101rtojami rezult\u0101ti.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3. Main\u012bga testa \u0101truma iesp\u0113ja<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Testeris pied\u0101v\u0101 main\u012bga testa \u0101truma iesp\u0113ju, kas \u013cauj elast\u012bgi veikt test\u0113\u0161anu, lai piel\u0101gotos da\u017e\u0101diem materi\u0101liem un pras\u012bb\u0101m. \u0160\u012b funkcija nodro\u0161ina, ka testeris var piel\u0101goties da\u017e\u0101diem test\u0113\u0161anas apst\u0101k\u013ciem un standartiem.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">4. Vair\u0101ki paraugu d\u017eigi un adatu veidi<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Lai piel\u0101gotos da\u017e\u0101diem test\u0113\u0161anas scen\u0101rijiem, testeris pied\u0101v\u0101 vair\u0101kus paraugus un adatu veidus. \u0160\u012b daudzpus\u012bba nodro\u0161ina, ka testeris var r\u012bkoties ar da\u017e\u0101du izm\u0113ru flakoniem un aizb\u0101\u017e\u0146iem un materi\u0101liem.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">5. Dro\u0161\u012bbas l\u012bdzek\u013ci<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Adatas caurlaid\u012bbas testeris ietver dro\u0161\u012bbas elementus, piem\u0113ram, poz\u012bcijas ierobe\u017eot\u0101jus un p\u0101rslodzes aizsardz\u012bbu. \u0160\u012bs funkcijas nodro\u0161ina operatora un apr\u012bkojuma dro\u0161\u012bbu, nov\u0113r\u0161ot boj\u0101jumus un nodro\u0161inot dro\u0161u darb\u012bbu.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">6. Autom\u0101tisk\u0101s atgrie\u0161anas funkcija<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Autom\u0101tisk\u0101 atgrie\u0161anas funkcija ietaupa darb\u012bbas laiku, atgrie\u017eot adatu s\u0101kuma st\u0101vokl\u012b p\u0113c katras p\u0101rbaudes. \u0160\u012b funkcija uzlabo test\u0113\u0161anas procesa efektivit\u0101ti, nodro\u0161inot \u0101tr\u0101ku izpildes laiku.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">7. Iegultais punktmatricas tipa mikroprinteris<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Datu ilgsto\u0161ai glab\u0101\u0161anai testeris ir apr\u012bkots ar iegultu punktmatricas tipa mikroprinteri. \u0160is printeris \u013cauj nekav\u0113joties izdruk\u0101t testa rezult\u0101tus, atvieglojot uzskaiti un anal\u012bzi.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">III. P\u0101rbaudes metodes<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">1. Proced\u016bra<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Adatas caurlaid\u012bbas testa veik\u0161ana ietver vair\u0101kas darb\u012bbas:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Paraugu sagatavo\u0161ana<\/strong>: Flakonus un aizb\u0101\u017e\u0146us sagatavo un not\u012bra, lai nodro\u0161in\u0101tu, ka tajos nav pies\u0101r\u0146ot\u0101ju.<\/li>\n\n\n\n<li><strong>Kalibr\u0113\u0161ana un iestat\u012b\u0161ana<\/strong>: testeris ir kalibr\u0113ts, un atbilsto\u0161ie iestat\u012bjumi ir konfigur\u0113ti, pamatojoties uz test\u0113jam\u0101 aizb\u0101\u017e\u0146a un adatas veidu.<\/li>\n\n\n\n<li><strong>P\u0101rbaudes izpilde<\/strong>: Adata tiek ievietota aizb\u0101zn\u012b, un tiek izm\u0113r\u012bts un re\u0123istr\u0113ts iespie\u0161anai nepiecie\u0161amais sp\u0113ks.<\/li>\n\n\n\n<li><strong>Datu ierakst\u012b\u0161ana<\/strong>: Rezult\u0101ti tiek dokument\u0113ti, un dati tiek analiz\u0113ti, lai noteiktu aizb\u0101\u017e\u0146a kvalit\u0101ti un veiktsp\u0113ju.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"Medic\u012bnisk\u0101 \u0161\u013circes adatas punkcijas test\u0113\u0161ana | Testa instrumentu piel\u0101go\u0161ana\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/6D2saICCxCA?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<\/div><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">2. Datu anal\u012bze<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Anal\u012bze ietver iespie\u0161an\u0101s sp\u0113ka interpret\u0101ciju un aizb\u0101\u017e\u0146a integrit\u0101tes nov\u0113rt\u0113\u0161anu. Parastie datu izvades form\u0101ti ietver grafikus un diagrammas, kas par\u0101da iespie\u0161an\u0101s sp\u0113ku laika gait\u0101, nodro\u0161inot skaidru vizu\u0101lu testa rezult\u0101tu att\u0113lojumu.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">IV. Atbilst\u012bba standartiem<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">1. ISO\u00a08871-5<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">ISO 8871-5 nosaka pras\u012bbas elastom\u0113ra deta\u013c\u0101m, ko izmanto farmaceitiskaj\u0101 iepakojum\u0101, tostarp flakonu aizb\u0101\u017e\u0146iem. \u0160aj\u0101 standart\u0101 ir aprakst\u012bti testi, kas nepiecie\u0161ami, lai nodro\u0161in\u0101tu materi\u0101lu kvalit\u0101ti un veiktsp\u0113ju, un iz\u0161\u0137iro\u0161ais aspekts ir adatu caurlaid\u012bba. Atbilst\u012bba ISO 8871-5 nodro\u0161ina, ka aizb\u0101\u017e\u0146i atbilst starptautiskajiem kvalit\u0101tes un dro\u0161\u012bbas standartiem.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2.\u00a0USP\u00a0381<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">USP 381 sniedz vadl\u012bnijas elastom\u0113ra aizb\u0101\u017e\u0146iem, ko izmanto injic\u0113jamo z\u0101\u013cu konteineros. Taj\u0101 ir iek\u013cautas \u012bpa\u0161as sada\u013cas, kas attiecas uz adatu caurdur\u0161anu, nodro\u0161inot, ka aizb\u0101\u017e\u0146i neapdraud z\u0101\u013cu sterilit\u0101ti vai integrit\u0101ti.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">V. Pieteikumi<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">1. Farm\u0101cijas r\u016bpniec\u012bba<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Farm\u0101cijas nozar\u0113 adatu caurlaid\u012bbas p\u0101rbaude nodro\u0161ina z\u0101\u013cu ievad\u012b\u0161anas sist\u0113mu dro\u0161\u012bbu un efektivit\u0101ti. P\u0101rbaudot, vai adatas var iek\u013c\u016bt aizb\u0101\u017e\u0146os bez p\u0101rm\u0113r\u012bga sp\u0113ka, \u0161is tests pal\u012bdz uztur\u0113t injic\u0113jamo medikamentu kvalit\u0101ti un uzticam\u012bbu.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2. Medic\u012bnisk\u0101s ier\u012bces<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Medic\u012bniskaj\u0101m ier\u012bc\u0113m, \u012bpa\u0161i t\u0101m, kas saist\u012btas ar injic\u0113jamo \u0101rst\u0113\u0161anu, adatas caurlaid\u012bbas p\u0101rbaude ir \u013coti svar\u012bga. Tas nodro\u0161ina, ka \u0161aj\u0101s ier\u012bc\u0113s izmantotie aizb\u0101\u017e\u0146i netrauc\u0113 medikamentu pieg\u0101di, saglab\u0101jot ier\u012bces kop\u0113jo veiktsp\u0113ju un dro\u0161\u012bbu.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3. Kvalit\u0101tes kontrole<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ra\u017eo\u0161an\u0101 kvalit\u0101tes kontrole ir b\u016btiska, lai uztur\u0113tu augstus standartus. Adatu caurlaid\u012bbas p\u0101rbaudei ir b\u016btiska noz\u012bme kvalit\u0101tes nodro\u0161in\u0101\u0161an\u0101, nodro\u0161inot, ka flakonu aizb\u0101\u017e\u0146i atbilst nepiecie\u0161amajiem darb\u012bbas krit\u0113rijiem, t\u0101d\u0113j\u0101di nov\u0113r\u0161ot iesp\u0113jam\u0101s probl\u0113mas galaprodukt\u0101.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">VII. FAQ<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Q1: Kas ir adatas caurlaid\u012bbas p\u0101rbaude?<br>A1: adatas caurlaid\u012bbas p\u0101rbaude m\u0113ra sp\u0113ku, kas nepiecie\u0161ams, lai adata iedurtos flakona aizb\u0101zn\u012b. \u0160is tests ir \u013coti svar\u012bgs, lai nodro\u0161in\u0101tu z\u0101\u013cu iepakojuma integrit\u0101ti un dro\u0161\u012bbu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2. jaut\u0101jums. K\u0101p\u0113c ir svar\u012bga atbilst\u012bba ISO 8871-5 un USP 381?<br>A2: Atbilst\u012bba <a href=\"https:\/\/www.iso.org\/standard\/68560.html\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">ISO\u00a08871-5<\/a> un USP 381 nodro\u0161ina, ka flakonu aizb\u0101\u017e\u0146i atbilst starptautiskajiem kvalit\u0101tes un dro\u0161\u012bbas standartiem, saglab\u0101jot injic\u0113jamo z\u0101\u013cu efektivit\u0101ti un dro\u0161\u012bbu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Q3: K\u0101 darbojas adatas caurlaid\u012bbas testeris?<br>A3: Testeris izmanto prec\u012bzu lod\u012b\u0161u skr\u016bvi un so\u013cu motoru, lai kontrol\u0113tu adatas kust\u012bbu, m\u0113rot iespie\u0161anai nepiecie\u0161amo sp\u0113ku. Rezult\u0101ti tiek re\u0123istr\u0113ti un analiz\u0113ti, lai nov\u0113rt\u0113tu aizb\u0101\u017e\u0146a veiktsp\u0113ju.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Q4: Vai testeri var piel\u0101got \u012bpa\u0161\u0101m vajadz\u012bb\u0101m?<br>A4: J\u0101, testeris pied\u0101v\u0101 vair\u0101kus paraugus un adatu tipus, k\u0101 ar\u012b main\u012bga testa \u0101truma iesp\u0113jas, kas \u013cauj piel\u0101got, lai atbilstu \u012bpa\u0161\u0101m test\u0113\u0161anas pras\u012bb\u0101m.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Q5: K\u0101das ir automatiz\u0113ta adatas caurlaid\u012bbas testera izmanto\u0161anas priek\u0161roc\u012bbas?<br>A5: Automatiz\u0101cija uzlabo test\u0113\u0161anas efektivit\u0101ti un konsekvenci, samazinot cilv\u0113ku k\u013c\u016bdu iesp\u0113jam\u012bbu un nodro\u0161inot ticamus un atk\u0101rtojamus rezult\u0101tus.<\/p>","protected":false},"excerpt":{"rendered":"<p>Adatas caurlaid\u012bbas test\u0113\u0161ana m\u0113ra, vai adata var iek\u013c\u016bt aizb\u0101\u017e\u0146\u0101 bez p\u0101rm\u0113r\u012bga sp\u0113ka, nov\u0113r\u0161ot adatas boj\u0101jumus vai z\u0101\u013cu pies\u0101r\u0146ojumu.<\/p>","protected":false},"featured_media":0,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"product-category":[454,434,513,438,495,593,439,619],"product-tag":[],"class_list":["post-9553","products","type-products","status-publish","hentry","product-category-custom-lab-testing-instruments-manufacturer","product-category-iso","product-category-iso-8871-5","product-category-medical-and-pharmaceutical-testing","product-category-pharmaceutical-testing","product-category-syringe-testing","product-category-usp","product-category-usp-381"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/products\/9553","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/types\/products"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/media?parent=9553"}],"wp:term":[{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/product-category?post=9553"},{"taxonomy":"product-tag","embeddable":true,"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/product-tag?post=9553"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}