{"id":9583,"date":"2026-02-02T14:53:24","date_gmt":"2026-02-02T06:53:24","guid":{"rendered":"https:\/\/www.packqc.com\/products\/syringe-leak-testing-machine\/"},"modified":"2026-04-16T15:11:39","modified_gmt":"2026-04-16T07:11:39","slug":"syringe-leak-testing-machine","status":"publish","type":"products","link":"https:\/\/www.packqc.com\/lv\/products\/syringe-leak-testing-machine\/","title":{"rendered":"SLT-02 \u0160\u013cir\u010du nopl\u016bdes testeris"},"content":{"rendered":"<p>\u0160\u013cir\u010du nopl\u016bdes p\u0101rbaude ir b\u016btisks process, lai nodro\u0161in\u0101tu da\u017e\u0101d\u0101s medic\u012bnas un farm\u0101cijas nozar\u0113s izmantoto zem\u0101das \u0161\u013cir\u010du kvalit\u0101ti un dro\u0161\u012bbu. \u0160\u013cir\u010du herm\u0113tiskuma p\u0101rbaudes ma\u0161\u012bnai ir b\u016btiska noz\u012bme gaisa nopl\u016bdes noteik\u0161an\u0101 aiz virzu\u013ca aizb\u0101\u017e\u0146a un \u0161\u013circes bl\u012bv\u0113juma integrit\u0101tes nodro\u0161in\u0101\u0161an\u0101.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Kas ir \u0161\u013circes nopl\u016bdes p\u0101rbaude?<\/h2>\n\n\n\n<p>\u0160\u013circes nopl\u016bdes test\u0113\u0161ana tiek veikta, lai p\u0101rbaud\u012btu, vai \u0161\u013circes virzu\u013ca aizb\u0101zni un bl\u012bves ne\u013cauj gaisam izpl\u016bst cauri noteiktos spiediena apst\u0101k\u013cos. \u0160is tests nodro\u0161ina, ka \u0161\u013circes ir bez nopl\u016bd\u0113m, kas var\u0113tu apdraud\u0113t to funkcionalit\u0101ti, jo \u012bpa\u0161i lietojumiem, kur precizit\u0101te un sterilit\u0101te ir \u013coti svar\u012bga, piem\u0113ram, insul\u012bna injekcij\u0101m vai vakc\u012bn\u0101m.<\/p>\n\n\n\n<p>Nopl\u016bdes test\u0101 \u0161\u013circi da\u013c\u0113ji piepilda ar destil\u0113tu \u016bdeni, un, lai p\u0101rbaud\u012btu bl\u012bv\u0113jumu un virzu\u013ca aizb\u0101\u017e\u0146a integrit\u0101ti, tiek piem\u0113rots vakuums. Ja caur \u0161\u012bm sast\u0101vda\u013c\u0101m nopl\u016bst gaiss, tas nor\u0101da, ka \u0161\u013circe var neatbilst nepiecie\u0161amajiem kvalit\u0101tes standartiem.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u0160\u013cir\u010du nopl\u016bdes test\u0113\u0161anas iek\u0101rtas sist\u0113mas p\u0101rskats<\/h2>\n\n\n\n<p>The <strong>SLT-02 \u0160\u013cir\u010du nopl\u016bdes testeris<\/strong> sast\u0101v no lietot\u0101jam draudz\u012bga vad\u012bbas bloka, \u0161\u013circes stat\u012bva un caurul\u012btes \u0161\u013circes nostiprin\u0101\u0161anai testa laik\u0101. Sist\u0113ma darbojas, ievadot saspiestu gaisu vad\u012bbas blok\u0101, kas izmanto Venturi caurul\u012bti, lai rad\u012btu prec\u012bzu vakuumu \u0161\u013circ\u0113. Sist\u0113mas konstrukcija nodro\u0161ina stabilu vakuuma notur\u012bbu vis\u0101 test\u0113\u0161anas proces\u0101, nodro\u0161inot prec\u012bzus un atk\u0101rtojamus rezult\u0101tus.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Galven\u0101s iez\u012bmes<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Stabila vakuuma tur\u0113\u0161ana<\/strong>: SLT-02 nodro\u0161ina vienm\u0113r\u012bgu vakuuma spiedienu vis\u0101 testa laik\u0101, lai prec\u012bzi noteiktu gaisa nopl\u016bdi vai virzu\u013ca aizb\u012bd\u0146a atdal\u012b\u0161anos.<\/li>\n\n\n\n<li><strong>Efekt\u012bva vakuuma \u0123ener\u0113\u0161ana<\/strong>: Iek\u0101rta efekt\u012bvi rada nepiecie\u0161amo negat\u012bvo spiedienu, nep\u0101rtraukti uzturot vajadz\u012bgos testa apst\u0101k\u013cus.<\/li>\n\n\n\n<li><strong>Regul\u0113jams stiprin\u0101jums<\/strong>: \u0160\u013circes stiprin\u0101jumu var viegli piel\u0101got, lai piel\u0101gotu da\u017e\u0101da tilpuma \u0161\u013circ\u0113m, padarot SLT-02 univers\u0101lu da\u017e\u0101du veidu un izm\u0113ru \u0161\u013circ\u0113m.<\/li>\n\n\n\n<li><strong>Lietot\u0101jam draudz\u012bga darb\u012bba<\/strong>: SLT-02 ir izstr\u0101d\u0101ts t\u0101, lai to b\u016btu viegli lietot, ar vienk\u0101r\u0161u iestat\u012b\u0161anas procesu un autom\u0101tisku darb\u012bbu p\u0113c testa uzs\u0101k\u0161anas.<\/li>\n\n\n\n<li><strong>Ilgm\u016b\u017e\u012bgs kalpo\u0161anas laiks<\/strong>: SLT-02 ir paredz\u0113ts ilgsto\u0161ai lieto\u0161anai, t\u0101p\u0113c ir iztur\u012bgs un uzticams, nodro\u0161inot nep\u0101rtrauktu darb\u012bbu laika gait\u0101 ar minim\u0101lu apkopi.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Tehnisk\u0101 iez\u012bme<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>P\u0101rbaudes diapazons<\/strong><\/td><td>0 ~ 90KPa<\/td><\/tr><tr><td><strong>Gaisa iepl\u016bde<\/strong><\/td><td>0,6 ~ 0,7 Mpa<\/td><\/tr><tr><td><strong>Testa laiks<\/strong><\/td><td>9999H<\/td><\/tr><tr><td><strong>Jauda<\/strong><\/td><td>220V<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Konfigur\u0101cija<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>SLT-02 nopl\u016bdes testera vad\u012bbas bloks<\/strong><\/li>\n\n\n\n<li><strong>\u0160\u013cir\u010du stat\u012bvs<\/strong><\/li>\n\n\n\n<li><strong>Caurule \u0161\u013circes savienojumam<\/strong><\/li>\n\n\n\n<li><strong>Baro\u0161anas vads<\/strong><\/li>\n\n\n\n<li><strong>Dro\u0161in\u0101t\u0101js<\/strong><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u0160\u013circes nopl\u016bdes test\u0113\u0161anas ma\u0161\u012bnas testa princips<\/h2>\n\n\n\n<p>Test\u0113\u0161anas process s\u0101kas ar \u0161\u013circes sprauslas savieno\u0161anu ar sader\u012bgu savienojuma cauruli. P\u0113c tam \u0161\u013circi da\u013c\u0113ji piepilda ar \u016bdeni. Ar sprauslas pal\u012bdz\u012bbu tiek rad\u012bts kontrol\u0113ts negat\u012bvs spiediens, radot \u0161\u013circes iek\u0161pus\u0113 vakuumu. P\u0113c tam sist\u0113ma uzrauga, vai \u0161\u013circ\u0113 nav notikusi gaisa nopl\u016bde aiz virzu\u013ca aizb\u0101\u017e\u0146a vai bl\u012bv\u0113juma. Turkl\u0101t t\u0101 nov\u0113rt\u0113, vai virzu\u013ca aizb\u0101zni var atdal\u012bt no virzu\u013ca. \u0160is process imit\u0113 re\u0101los apst\u0101k\u013cus, kad \u0161\u013circ\u0113m j\u0101saglab\u0101 herm\u0113tiskums un funkcionalit\u0101te da\u017e\u0101dos spiedienos.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u0160\u013cir\u010du nopl\u016bdes test\u0113\u0161anas iek\u0101rtu priek\u0161roc\u012bbas<\/h2>\n\n\n\n<p>\u0160\u013cir\u010du nopl\u016bdes test\u0113\u0161anas iek\u0101rtas sniedz vair\u0101kas priek\u0161roc\u012bbas, jo \u012bpa\u0161i ra\u017eot\u0101jiem un kvalit\u0101tes kontroles person\u0101lam:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Precizit\u0101te un precizit\u0101te<\/strong>: \u0160\u012bs iek\u0101rtas nodro\u0161ina \u013coti prec\u012bzus rezult\u0101tus, nodro\u0161inot, ka \u0161\u013circes ir bez nopl\u016bd\u0113m un atbilst ISO standartiem.<\/li>\n\n\n\n<li><strong>Kvalit\u0101tes nodro\u0161in\u0101\u0161ana<\/strong>: Atkl\u0101jot pat vismaz\u0101k\u0101s nopl\u016bdes, iek\u0101rta pal\u012bdz nodro\u0161in\u0101t, ka \u0161\u013circes ir dro\u0161as izmanto\u0161anai medic\u012bnisk\u0101s proced\u016br\u0101s.<\/li>\n\n\n\n<li><strong>Atbilst\u012bba<\/strong>: \u0160\u013cir\u010du nopl\u016bdes test\u0113\u0161anas iek\u0101rtas pal\u012bdz ra\u017eot\u0101jiem iev\u0113rot ISO 7886-1 standartus, kas ir \u013coti svar\u012bgi, lai ieg\u016btu sertifik\u0101tus un nodro\u0161in\u0101tu savu produktu kvalit\u0101ti.<\/li>\n\n\n\n<li><strong>Efektivit\u0101te<\/strong>: Automatiz\u0113tas test\u0113\u0161anas sist\u0113mas racionaliz\u0113 test\u0113\u0161anas procesu, nodro\u0161inot liel\u0101ku caurlaidsp\u0113ju un samazinot cilv\u0113ka k\u013c\u016bdu skaitu.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">ISO 7886-1 Gaisa nopl\u016bdes test\u0113\u0161anas metode<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">ISO 7886-1 B pielikums<\/h3>\n\n\n\n<p><a href=\"https:\/\/www.packqc.com\/lv\/product-category\/iso\/iso-7886-1\/\" target=\"_blank\" rel=\"noopener\"><strong>ISO 7886-1<\/strong><\/a> ir starptautisks standarts, kur\u0101 izkl\u0101st\u012btas sterilo zem\u0101das \u0161\u013cir\u010du specifik\u0101cijas, tostarp vadl\u012bnijas attiec\u012bb\u0101 uz <strong>gaisa nopl\u016bdes p\u0101rbaude<\/strong>. Konkr\u0113ti, <strong>ISO 7886-1 B pielikums<\/strong> sniedz detaliz\u0113tu testa metodi, lai noteiktu gaisa nopl\u016bdi gar \u0161\u013circes virzu\u013ca aizb\u0101zni aspir\u0101cijas laik\u0101, kas ir \u013coti svar\u012bgi, lai nodro\u0161in\u0101tu \u0161\u013circes funkcionalit\u0101ti.<\/p>\n\n\n\n<p>Key elements of ISO 7886-1 testing include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Testa aparat\u016bra<\/strong>: Testa komplekt\u0101cij\u0101 ietilpst vakuuma sist\u0113ma, manometrs, vakuumnecaurlaid\u012bgi v\u0101rsti un skava \u0161\u013circes nostiprin\u0101\u0161anai.<\/li>\n\n\n\n<li><strong>Testa nosac\u012bjumi<\/strong>: \u0160\u013circe tiek pak\u013cauta vakuuma videi, lai imit\u0113tu apst\u0101k\u013cus, k\u0101dos t\u0101 var\u0113tu atrasties lieto\u0161anas laik\u0101. Testa laik\u0101 tiek p\u0101rbaud\u012bta virzu\u013ca sp\u0113ja notur\u0113ties piestiprin\u0101tam un tiek kontrol\u0113ts, vai gaisa nopl\u016bde nav notikusi \u0101rpus bl\u012bv\u0113m.<\/li>\n\n\n\n<li><strong>Testa zi\u0146ojums<\/strong>: Rezult\u0101ti j\u0101dokument\u0113, tostarp \u0161\u013circes identit\u0101te, nopl\u016bdes gad\u012bjumi, spiediena izmai\u0146as un tas, vai atdal\u012bj\u0101s virzu\u013ca aizb\u0101zni.<\/li>\n<\/ul>\n\n\n\n<p>\u0160is standarts nodro\u0161ina, ka \u0161\u013circes atbilst medic\u012bniskai lieto\u0161anai nepiecie\u0161amajiem krit\u0113rijiem, t\u0101d\u0113j\u0101di aizsarg\u0101jot gan pacientus, gan vesel\u012bbas apr\u016bpes speci\u0101listus.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Test\u0113\u0161anas process<\/h2>\n\n\n\n<p>The <strong>gaisa nopl\u016bdes tests<\/strong> ir standarta proced\u016bra, ko izmanto \u0161\u013cir\u010du nopl\u016bdes test\u0113\u0161an\u0101. Saska\u0146\u0101 ar <strong>ISO 7886-1<\/strong>, \u0161\u012b metode ietver vakuuma piem\u0113ro\u0161anu \u0161\u013circei un spiediena izmai\u0146u m\u0113r\u012b\u0161anu laika gait\u0101. \u0160eit ir \u012bss ieskats tipiskajos posmos:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0160\u013circes uzpild\u012b\u0161ana<\/strong>: \u0160\u013circe ir piepild\u012bta ar destil\u0113tu \u016bdeni, parasti vismaz 25% no t\u0101s nomin\u0101l\u0101s ietilp\u012bbas.<\/li>\n\n\n\n<li><strong>Vakuuma uzkl\u0101\u0161ana<\/strong>: \u0160\u013circe ir savienota ar vakuuma sist\u0113mu, kas rada kontrol\u0113tu negat\u012bvu spiedienu, kas parasti sasniedz 88 kPa zem apk\u0101rt\u0113j\u0101s vides atmosf\u0113ras spiediena.<\/li>\n\n\n\n<li><strong>Nopl\u016b\u017eu nov\u0113ro\u0161ana<\/strong>: P\u0113c tam \u0161\u013circi p\u0101rbauda, vai nav gaisa nopl\u016bdes aiz virzu\u013ca aizb\u0101\u017e\u0146a vai bl\u012bv\u0113juma. Ar manometra pal\u012bdz\u012bbu p\u0101rbauda, vai spiediens nesamazin\u0101s, kas liecina par nopl\u016bdi.<\/li>\n\n\n\n<li><strong>Virzu\u013ca atdal\u012b\u0161an\u0101s p\u0101rbaude<\/strong>: Test\u0101 ar\u012b nov\u0113rt\u0113, vai vakuuma apst\u0101k\u013cos virzu\u013ca aizb\u0101zni var atdal\u012bt no virzu\u013ca.<\/li>\n<\/ol>\n\n\n\n<p>\u0160\u012b metode \u013cauj ticami nov\u0113rt\u0113t, vai \u0161\u013circes bl\u012bves un virzu\u013ca aizb\u0101zni ir neboj\u0101tas un funkcion\u0113.<\/p>\n\n\n\n<p>The <strong>SLT-02 \u0160\u013cir\u010du nopl\u016bdes testeris<\/strong> ir b\u016btisks r\u012bks \u0161\u013cir\u010du ra\u017eot\u0101jiem un kvalit\u0101tes kontroles komand\u0101m, kam j\u0101nodro\u0161ina, lai \u0161\u013circes b\u016btu herm\u0113tiskas un atbilstu nepiecie\u0161amajiem starptautiskajiem standartiem, piem\u0113ram. <strong><a href=\"https:\/\/www.iso.org\/standard\/64790.html\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">ISO 7886-1<\/a> B pielikums<\/strong>. \u0160is uzticamais un efekt\u012bvais test\u0113\u0161anas risin\u0101jums garant\u0113 \u0161\u013cir\u010du integrit\u0101ti, padarot to par neat\u0146emamu kvalit\u0101tes nodro\u0161in\u0101\u0161anas procesa sast\u0101vda\u013cu medic\u012bnas un farm\u0101cijas nozar\u0113.<\/p>","protected":false},"excerpt":{"rendered":"<p>Syringe leak testing is a crucial process in ensuring the quality and safety of hypodermic syringes used in various medical and pharmaceutical applications.<\/p>","protected":false},"featured_media":5336,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"product-category":[434,437,484,438,495,593,517],"product-tag":[],"class_list":["post-9583","products","type-products","status-publish","has-post-thumbnail","hentry","product-category-iso","product-category-iso-7886-1","product-category-leak-testing","product-category-medical-and-pharmaceutical-testing","product-category-pharmaceutical-testing","product-category-syringe-testing","product-category-vacuum-leak-tester"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/products\/9583","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/types\/products"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/media\/5336"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/media?parent=9583"}],"wp:term":[{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/product-category?post=9583"},{"taxonomy":"product-tag","embeddable":true,"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/product-tag?post=9583"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}