{"id":9584,"date":"2026-02-02T14:53:24","date_gmt":"2026-02-02T06:53:24","guid":{"rendered":"https:\/\/www.packqc.com\/products\/syringe-liquid-leak-tester-iso-7886-1\/"},"modified":"2026-04-16T15:20:05","modified_gmt":"2026-04-16T07:20:05","slug":"syringe-liquid-leak-tester-iso-7886-1","status":"publish","type":"products","link":"https:\/\/www.packqc.com\/lv\/products\/syringe-liquid-leak-tester-iso-7886-1\/","title":{"rendered":"SPPT-01 \u0160\u013circes pozit\u012bv\u0101 spiediena herm\u0113tiskuma testeris"},"content":{"rendered":"<p>Vienreizlietojamo \u0161\u013cir\u010du integrit\u0101tes nodro\u0161in\u0101\u0161ana ir \u013coti svar\u012bga pacientu dro\u0161\u012bbai un produktu kvalit\u0101tei farm\u0101cijas un medic\u012bnas ier\u012b\u010du ra\u017eo\u0161an\u0101. Viens no svar\u012bg\u0101kajiem nov\u0113rt\u0113jumiem ir <strong data-start=\"593\" data-end=\"621\">\u0161\u013circes \u0161\u0137idruma nopl\u016bdes tests<\/strong>, jo \u012bpa\u0161i pie virzu\u013ca aizb\u012bd\u0146a aizb\u012bd\u0146a saspie\u0161anas laik\u0101. Ar \u0161o testu p\u0101rbauda, vai rodas nopl\u016bde, ja virzuli kontrol\u0113tos apst\u0101k\u013cos pak\u013cauj gan aksi\u0101lam, gan radi\u0101lam sp\u0113kam. Cell Instruments pied\u0101v\u0101 progres\u012bvu risin\u0101jumu, lai veiktu \u0161o testu ar precizit\u0101ti un atk\u0101rtojam\u012bbu -<strong data-start=\"914\" data-end=\"972\">SPPT-01 \u0161\u013circes pozit\u012bv\u0101 spiediena herm\u0113tiskuma testeris<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u0160\u013circes \u0161\u0137idruma nopl\u016bdes testeris - ISO 7886-1<\/h2>\n\n\n\n<p>Laboratorij\u0101m un ra\u017eot\u0101jiem, kas v\u0113las pan\u0101kt atbilst\u012bbu ISO 7886-1 D pielikumam, ir paredz\u0113tas <strong data-start=\"3251\" data-end=\"3305\">SPPT-01 \u0160\u013circes pozit\u012bv\u0101 spiediena herm\u0113tiskuma testeris<\/strong> l\u012bdz <strong data-start=\"3309\" data-end=\"3329\">\u0160\u016bnu instrumenti<\/strong> nodro\u0161ina piln\u012bb\u0101 automatiz\u0113tu un prec\u012bzu test\u0113\u0161anas risin\u0101jumu. Izstr\u0101d\u0101ts ar <strong data-start=\"3403\" data-end=\"3428\">PLC kontrol\u0113ta sist\u0113ma<\/strong> un <strong data-start=\"3433\" data-end=\"3465\">7 collu sk\u0101rienekr\u0101na saskarne<\/strong>, SPPT-01 pied\u0101v\u0101:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"3490\" data-end=\"3516\">Regul\u0113jams testa \u0101trums<\/strong> (1-500 mm\/min)<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3534\" data-end=\"3563\">Augstas precizit\u0101tes m\u0113r\u012bjumi<\/strong> (0,01 mm)<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3576\" data-end=\"3604\">Main\u0101mie \u0137erme\u0146i<\/strong> da\u017e\u0101du izm\u0113ru \u0161\u013circ\u0113m<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3633\" data-end=\"3676\">Sp\u0113ka pielik\u0161ana uz s\u0101niem un uz leju<\/strong> vien\u0101 integr\u0113t\u0101 platform\u0101<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3706\" data-end=\"3729\">P\u0101rslodzes aizsardz\u012bba<\/strong> un <strong style=\"font-size: 16px;\" data-start=\"3734\" data-end=\"3754\">autom\u0101tiska atgrie\u0161an\u0101s<\/strong> uzlabotai dro\u0161\u012bbai<\/li>\n\n\n\n<li>Uz borta <strong style=\"font-size: 16px;\" data-start=\"3786\" data-end=\"3802\">mikroprinteris<\/strong> t\u016bl\u012bt\u0113jai zi\u0146o\u0161anai par testu<\/li>\n<\/ul>\n\n\n\n<p>\u0160\u012bs funkcijas nodro\u0161ina konsekvenci, precizit\u0101ti un atbilst\u012bbu pasaules regulat\u012bvajiem standartiem, piem\u0113ram. <strong data-start=\"3928\" data-end=\"3942\">ISO 7886-1<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Galvenais parametrs<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Slodzes \u0161\u016bna<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">200\u00a0N (vai p\u0113c vajadz\u012bbas)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Testa \u0101trums<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">1 ~ 500 mm\/min<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Precizit\u0101te<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">0,01 mm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Jauda<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">110 ~ 220 V<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Pielietojums un noz\u012bme nozar\u0113<\/h2>\n\n\n\n<p>\u0160\u013cir\u010du \u0161\u0137idruma nopl\u016bdes tests attiecas uz:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Zem\u0101das \u0161\u013circes<\/li>\n\n\n\n<li>Iepriek\u0161 uzpild\u012btas \u0161\u013circes<\/li>\n\n\n\n<li>Medic\u012bnisk\u0101s injekciju sist\u0113mas<\/li>\n\n\n\n<li>Kvalit\u0101tes p\u0101rbau\u017eu un regulat\u012bv\u0101s test\u0113\u0161anas laboratorijas<\/li>\n<\/ul>\n\n\n\n<p>Iek\u013caujot \u0161o testu kvalit\u0101tes kontroles protokolos, uz\u0146\u0113mumi <strong data-start=\"4253\" data-end=\"4271\">farm\u0101cijas<\/strong>, <strong data-start=\"4273\" data-end=\"4291\">medic\u012bnas ier\u012bce<\/strong>, un <strong data-start=\"4297\" data-end=\"4318\">iepako\u0161anas nozares<\/strong> var atbilst starptautiskaj\u0101m normat\u012bvaj\u0101m pras\u012bb\u0101m un uzlabot produktu uzticam\u012bbu.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u0160\u013circes \u0161\u0137idruma nopl\u016bdes testa noz\u012bme<\/h2>\n\n\n\n<p>\u0160\u013cir\u010du \u0161\u0137idruma nopl\u016bdes tests ir b\u016btisks sterilu zem\u0101das \u0161\u013cir\u010du ra\u017eo\u0161anas kvalit\u0101tes nodro\u0161in\u0101\u0161anai. \u0160\u013circes nopl\u016bde rada iev\u0113rojamus riskus, tostarp infic\u0113\u0161anos, neprec\u012bzu doz\u0113\u0161anu un neveiksmes ievad\u012b\u0161anas laik\u0101. Veicot kontrol\u0113tu <strong data-start=\"1288\" data-end=\"1316\">\u0161\u013circes \u0161\u0137idruma nopl\u016bdes tests<\/strong>, ra\u017eot\u0101ji var identific\u0113t nepiln\u012bbas \u0161\u013circes virzu\u013ca aizb\u0101\u017e\u0146a konstrukcij\u0101 un nov\u0113rst defekt\u012bvu vien\u012bbu non\u0101k\u0161anu tirg\u016b.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Testa metode, kas balst\u012bta uz ISO 7886-1 D pielikumu<\/h2>\n\n\n\n<p><a href=\"https:\/\/www.packqc.com\/lv\/product-category\/iso\/iso-7886-1\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"1506\" data-end=\"1520\">ISO 7886-1<\/strong><\/a> ir starptautiskais standarts steril\u0101m vienreiz lietojam\u0101m zem\u0101das \u0161\u013circ\u0113m. . <strong data-start=\"1603\" data-end=\"1625\">ISO 7886-1 test\u0113\u0161ana<\/strong> proced\u016bra nodro\u0161ina \u0161\u013circes meh\u0101nisk\u0101s un funkcion\u0101l\u0101s \u012bpa\u0161\u012bbas, tostarp notur\u012bbu pret nopl\u016bdi. Konkr\u0113ti, <strong data-start=\"1746\" data-end=\"1768\">ISO 7886-1 D pielikums<\/strong> izkl\u0101sta <strong data-start=\"1782\" data-end=\"1865\">testa metode \u0161\u0137idruma nopl\u016bdes noteik\u0161anai \u0161\u013circes virzu\u013ca aizb\u0101\u017e\u0146a aizb\u0101\u017e\u0146a viet\u0101 saspie\u0161anas apst\u0101k\u013cos<\/strong>.<\/p>\n\n\n\n<p><strong data-start=\"1506\" data-end=\"1520\">ISO 7886-1<\/strong> ir starptautiskais standarts steril\u0101m vienreiz lietojam\u0101m zem\u0101das \u0161\u013circ\u0113m. . <strong data-start=\"1603\" data-end=\"1625\">ISO 7886-1 test\u0113\u0161ana<\/strong> proced\u016bra nodro\u0161ina \u0161\u013circes meh\u0101nisk\u0101s un funkcion\u0101l\u0101s \u012bpa\u0161\u012bbas, tostarp notur\u012bbu pret nopl\u016bdi. Konkr\u0113ti, <strong data-start=\"1746\" data-end=\"1768\">ISO 7886-1 D pielikums<\/strong> izkl\u0101sta <strong data-start=\"1782\" data-end=\"1865\">testa metode \u0161\u0137idruma nopl\u016bdes noteik\u0161anai \u0161\u013circes virzu\u013ca aizb\u0101\u017e\u0146a aizb\u0101\u017e\u0146a viet\u0101 saspie\u0161anas apst\u0101k\u013cos<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">ISO 7886-1 D pielikum\u0101 noteiktie test\u0113\u0161anas principi<\/h2>\n\n\n\n<p>D pielikuma proced\u016bras m\u0113r\u0137is ir simul\u0113t slikt\u0101k\u0101 gad\u012bjuma apst\u0101k\u013cus, apvienojot aksi\u0101l\u0101s un radi\u0101l\u0101s slodzes uz \u0161\u013circes virzuli:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0160\u013circi vispirms piepilda ar <strong data-start=\"2076\" data-end=\"2095\">destil\u0113ts \u016bdens<\/strong> p\u0101rsniedz t\u0101 nomin\u0101lo jaudu.<\/li>\n\n\n\n<li>P\u0113c gaisa izspie\u0161anas tilpums tiek noregul\u0113ts l\u012bdz nomin\u0101lajam l\u012bmenim.<\/li>\n\n\n\n<li>Sprausla ir nosl\u0113gta, izmantojot <strong style=\"font-size: 16px;\" data-start=\"2223\" data-end=\"2252\">atskaites konusveida savienojums<\/strong> saska\u0146\u0101 ar ISO 80369-7 vai l\u012bdzv\u0113rt\u012bgu bl\u012bv\u0113jumu.<\/li>\n\n\n\n<li>A <strong style=\"font-size: 16px;\" data-start=\"2311\" data-end=\"2329\">s\u0101nu sp\u0113ks<\/strong> (0,25 N l\u012bdz 3 N), lai izrais\u012btu deform\u0101ciju.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"2396\" data-end=\"2414\">Aksi\u0101lais spiediens<\/strong> tiek rad\u012bts 200-300 kPa un uztur\u0113ts 30-35 sekundes.<\/li>\n\n\n\n<li>Jebkur\u0161 <strong style=\"font-size: 16px;\" data-start=\"2496\" data-end=\"2532\">nopl\u016bde aiz virzu\u013ca aizb\u0101\u017e\u0146a.<\/strong> p\u0101rbauda vizu\u0101li.<\/li>\n<\/ul>\n\n\n\n<p>\u0160\u012b metodika nodro\u0161ina, ka virzu\u013ca aizb\u012bdnis saglab\u0101 herm\u0113tisku bl\u012bv\u0113jumu spiediena un s\u0101nu slodzes apst\u0101k\u013cos, kas atbilst re\u0101l\u0101s pasaules apst\u0101k\u013ciem, kuri var\u0113tu izrais\u012bt boj\u0101jumus.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pras\u012bbas apr\u012bkojumam ISO 7886-1 D pielikuma D test\u0113\u0161anai<\/h2>\n\n\n\n<p>Lai prec\u012bzi veiktu \u0161\u013circes \u0161\u0137idruma nopl\u016bdes testu, ir nepiecie\u0161ams \u0161\u0101ds apr\u012bkojums:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0160\u013circes sprauslas bl\u012bv\u0113\u0161anas ier\u012bce.<\/li>\n\n\n\n<li>Armat\u016bra virzu\u013ca radi\u0101l\u0101 sp\u0113ka pielik\u0161anai.<\/li>\n\n\n\n<li>Spiediena paaugstin\u0101\u0161anas ier\u012bce, lai sasniegtu 200-300 kPa.<\/li>\n\n\n\n<li>Destil\u0113ts \u016bdens (18\u00b0C l\u012bdz 28\u00b0C) uzpild\u012b\u0161anas procesam.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">FAQ<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>K\u0101dam nol\u016bkam tiek izmantots \u0161\u013circes \u0161\u0137idruma nopl\u016bdes tests?<br>\u0160\u013circes \u0161\u0137idruma nopl\u016bdes test\u0101 tiek nov\u0113rt\u0113ts, vai virzu\u013ca aizb\u0101zni saspie\u017eot izdodas pareizi nosl\u0113gt, nov\u0113r\u0161ot nopl\u016bdes, kas var\u0113tu apdraud\u0113t sterilit\u0101ti vai doz\u0113\u0161anas precizit\u0101ti.<\/li>\n\n\n\n<li>K\u0101 Cell Instruments\u2019 SPPT-01 veic testu?<br>SPPT-01 testeris piem\u0113ro gan radi\u0101lo, gan aksi\u0101lo sp\u0113ku \u0161\u013circes virzulim, kam\u0113r sprausla ir nosl\u0113gta, imit\u0113jot slikt\u0101kos apst\u0101k\u013cus, lai noteiktu jebk\u0101du nopl\u016bdi aiz aizb\u0101\u017e\u0146a.<\/li>\n\n\n\n<li>K\u0101p\u0113c \u0161is tests ir svar\u012bgs kvalit\u0101tes kontrolei?<br>T\u0101 nodro\u0161ina, ka katra \u0161\u013circe dro\u0161i un prec\u012bzi pieg\u0101d\u0101 medikamentus, nov\u0113r\u0161ot pies\u0101r\u0146ojumu, devas zudumu vai injekcijas k\u013c\u016bmes.<\/li>\n\n\n\n<li>Vai SPPT-01 var izmantot da\u017e\u0101du izm\u0113ru \u0161\u013circ\u0113m?<br>J\u0101, SPPT-01 ir vair\u0101ki stiprin\u0101jumi, lai piel\u0101gotu to da\u017e\u0101diem \u0161\u013cir\u010du tipiem un tilpumiem, t\u0101d\u0113j\u0101di palielinot t\u0101 daudzpus\u012bbu da\u017e\u0101d\u0101m test\u0113\u0161anas vajadz\u012bb\u0101m.<\/li>\n<\/ol>\n\n\n\n<p>Dro\u0161\u012bbai un veiktsp\u0113jai ir b\u016btiski nodro\u0161in\u0101t, lai \u0161\u013circe zem spiediena sp\u0113tu saglab\u0101t herm\u0113tisku bl\u012bv\u0113jumu. . <strong data-start=\"4543\" data-end=\"4571\">\u0161\u013circes \u0161\u0137idruma nopl\u016bdes tests<\/strong>, k\u0101 noteikts <strong data-start=\"4587\" data-end=\"4609\"><a href=\"https:\/\/www.iso.org\/standard\/64790.html\" target=\"_blank\" rel=\"noopener nofollow\">ISO 7886-1<\/a> D pielikums<\/strong>, nodro\u0161ina standartiz\u0113tu un uzticamu metodi, lai nov\u0113rt\u0113tu \u0161o kritiski svar\u012bgo \u012bpa\u0161\u012bbu. Izmantojot t\u0101du prec\u012bzu un piln\u012bb\u0101 atbilsto\u0161u instrumentu k\u0101, piem. <strong data-start=\"4747\" data-end=\"4801\">SPPT-01 \u0160\u013circes pozit\u012bv\u0101 spiediena herm\u0113tiskuma testeris<\/strong> no <strong data-start=\"4807\" data-end=\"4827\">\u0160\u016bnu instrumenti<\/strong> pal\u012bdz ra\u017eot\u0101jiem uztur\u0113t kvalit\u0101tes standartus un aizsarg\u0101t galalietot\u0101jus.<\/p>","protected":false},"excerpt":{"rendered":"<p>Vienreizlietojamo \u0161\u013cir\u010du integrit\u0101tes nodro\u0161in\u0101\u0161ana ir \u013coti svar\u012bga pacientu dro\u0161\u012bbai un produktu kvalit\u0101tei farm\u0101cijas un medic\u012bnas ier\u012b\u010du ra\u017eo\u0161an\u0101. Viens no svar\u012bg\u0101kajiem nov\u0113rt\u0113jumiem ir \u0161\u013circes \u0161\u0137idruma nopl\u016bdes tests, jo \u012bpa\u0161i st\u016bres aizb\u0101\u017e\u0146a aizb\u0101\u017e\u0146a saspie\u0161anas laik\u0101. Ar \u0161o testu p\u0101rbauda, vai nerodas nopl\u016bde, ja virzuli pak\u013cauj gan aksi\u0101lai, gan radi\u0101lai [...].<\/p>","protected":false},"featured_media":0,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"product-category":[484,438,593],"product-tag":[],"class_list":["post-9584","products","type-products","status-publish","hentry","product-category-leak-testing","product-category-medical-and-pharmaceutical-testing","product-category-syringe-testing"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/products\/9584","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/types\/products"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/media?parent=9584"}],"wp:term":[{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/product-category?post=9584"},{"taxonomy":"product-tag","embeddable":true,"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/product-tag?post=9584"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}