{"id":9586,"date":"2026-02-02T14:53:24","date_gmt":"2026-02-02T06:53:24","guid":{"rendered":"https:\/\/www.packqc.com\/products\/syringe-tube-stiffness-tester\/"},"modified":"2026-04-16T15:32:27","modified_gmt":"2026-04-16T07:32:27","slug":"syringe-tube-stiffness-tester","status":"publish","type":"products","link":"https:\/\/www.packqc.com\/lv\/products\/syringe-tube-stiffness-tester\/","title":{"rendered":"TS-01 Caurules stinguma testeris"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Ievads \u0161\u013circes caurul\u012btes stinguma tester\u012b<\/h2>\n\n\n\n<p>Medic\u012bnisko ier\u012b\u010du ra\u017eo\u0161anas speci\u0101listiem, <strong data-start=\"577\" data-end=\"603\">\u0161\u013circes caurules stingr\u012bba<\/strong> ir iz\u0161\u0137iro\u0161a noz\u012bme zem\u0101das adatu uzticam\u012bbas, dro\u0161uma un lietojam\u012bbas nodro\u0161in\u0101\u0161an\u0101. Port\u0101ls <strong data-start=\"704\" data-end=\"737\">\u0160\u013circes caurules stinguma testeris<\/strong>, kas \u012bpa\u0161i izstr\u0101d\u0101ts ner\u016bs\u0113jo\u0161\u0101 t\u0113rauda adatu cauru\u013cu stingr\u012bbas nov\u0113rt\u0113\u0161anai, nodro\u0161ina uzticamu metodi kvalit\u0101tes kontrolei un standartu iev\u0113ro\u0161anai. \u0160is instruments, piem\u0113ram, Cell Instruments' <strong data-start=\"936\" data-end=\"945\">TS-01<\/strong>, ir nepiecie\u0161ams, lai izpild\u012btu pras\u012bbas, kas izkl\u0101st\u012btas <a href=\"https:\/\/www.packqc.com\/lv\/standard\/iso-9626\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"1005\" data-end=\"1017\">ISO 9626<\/strong><\/a>.<\/p>\n\n\n\n<p>St\u012bvums ir tie\u0161i saist\u012bts ar meh\u0101nisko integrit\u0101ti. Caurules, kur\u0101m tr\u016bkst atbilsto\u0161as stingr\u012bbas, lieto\u0161anas laik\u0101 var saliekties, sal\u016bzt vai deform\u0113ties, radot traumu, neprec\u012bzu doz\u0113\u0161anu vai pies\u0101r\u0146ojuma risku. Savuk\u0101rt p\u0101r\u0101k stingras caurules var nenodro\u0161in\u0101t pietiekamu elast\u012bbu, izraisot l\u016bzumus vai diskomfortu. . <strong data-start=\"1326\" data-end=\"1359\">\u0160\u013circes caurules stinguma testeris<\/strong> risina \u0161\u012bs probl\u0113mas, nodro\u0161inot prec\u012bzus, atk\u0101rtojamus m\u0113r\u012bjumus, kas atbilst pasaules standartiem.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">ISO 9626 un \u0161\u013cir\u010du caurul\u012b\u0161u stinguma test\u0113\u0161anas standarti<\/h2>\n\n\n\n<p><strong data-start=\"1534\" data-end=\"1546\">ISO 9626<\/strong>, konkr\u0113ti <strong data-start=\"1561\" data-end=\"1572\">B pielikums<\/strong>, defin\u0113 <strong data-start=\"1586\" data-end=\"1610\">standarta testa metode<\/strong> ner\u016bs\u0113jo\u0161\u0101 t\u0113rauda adatu cauru\u013cu stinguma m\u0113r\u012b\u0161anai. \u0160is garais atsl\u0113gas v\u0101rds...<strong data-start=\"1696\" data-end=\"1716\">ISO 9626 test\u0113\u0161ana<\/strong>-ir b\u016btiska ra\u017eot\u0101jiem, kuriem j\u0101pier\u0101da atbilst\u012bba starptautiskajiem medic\u012bnas ier\u012b\u010du noteikumiem.<\/p>\n\n\n\n<p>Saska\u0146\u0101 ar ISO 9626 B pielikumu:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Caurule tiek atbalst\u012bta abos galos, bet t\u0101s viduspunkt\u0101 ar \u0137\u012b\u013ca formas virzuli tiek pielikts sp\u0113ks l\u012bdz 60 N.<\/li>\n\n\n\n<li>Ieg\u016bto novirzi m\u0113ra ar precizit\u0101ti 0,01 mm.<\/li>\n\n\n\n<li>Tests nodro\u0161ina, ka caurules stingr\u012bba ir pie\u0146emam\u0101s robe\u017e\u0101s paredz\u0113tajam medic\u012bniskajam lietojumam.<\/li>\n<\/ul>\n\n\n\n<p>The <strong data-start=\"2167\" data-end=\"2200\">\u0160\u013circes caurules stinguma testeris<\/strong> Cell Instruments ir izstr\u0101d\u0101ts t\u0101, lai atbilstu vis\u0101m \u0161\u012bm pras\u012bb\u0101m, t\u0101p\u0113c tas ir ide\u0101li piem\u0113rots kvalit\u0101tes nodro\u0161in\u0101\u0161anas komand\u0101m un regulat\u012bvaj\u0101m iest\u0101d\u0113m.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">TS-01 \u0161\u013circes caurul\u012btes stinguma testera darba meh\u0101nisms un strukt\u016bra<\/h2>\n\n\n\n<p>The <strong data-start=\"2430\" data-end=\"2469\">TS-01 \u0161\u013circes caurul\u012btes stinguma testeris<\/strong> izmanto iztur\u012bgu un prec\u012bzu sist\u0113mu, kas izstr\u0101d\u0101ta t\u0101, lai samazin\u0101tu m\u0113r\u012bjumu k\u013c\u016bdas. T\u0101 izmanto:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>A <strong data-start=\"2562\" data-end=\"2586\">\u0137\u012b\u013ca formas virzu\u013ca<\/strong> ar 1 mm r\u0101diusu un 60\u00b0 sl\u012bpumu, k\u0101 nor\u0101d\u012bts ISO 9626 B pielikum\u0101.<\/li>\n\n\n\n<li>A <strong data-start=\"2662\" data-end=\"2685\">prec\u012bzijas slodzes kamera<\/strong> un kust\u012bgu krustgalvu, lai nodro\u0161in\u0101tu prec\u012bzu sp\u0113ka pielik\u0161anu.<\/li>\n\n\n\n<li>A <strong data-start=\"2750\" data-end=\"2764\">cauru\u013cu panna<\/strong> kas test\u0113jamo paraugu novieto tie\u0161i zem virzu\u013ca.<\/li>\n<\/ul>\n\n\n\n<p>\u0160\u012b konfigur\u0101cija imit\u0113 ISO noteiktos testa apst\u0101k\u013cus, nodro\u0161inot reproduc\u0113jam\u012bbu un datu integrit\u0101ti.<\/p>\n\n\n\n<p><strong data-start=\"2934\" data-end=\"2956\">Sist\u0113mas svar\u012bg\u0101kie notikumi:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"2961\" data-end=\"2976\">PLC vad\u012bba<\/strong> un <strong data-start=\"2981\" data-end=\"3008\">7 collu HMI sk\u0101rienekr\u0101ns<\/strong> saskarne<\/li>\n\n\n\n<li><strong data-start=\"3023\" data-end=\"3053\">Prec\u012bza lod\u012b\u0161u skr\u016bves piedzi\u0146a<\/strong> konsekventai \u0101truma kontrolei<\/li>\n\n\n\n<li><strong data-start=\"3087\" data-end=\"3105\">Main\u012bgs \u0101trums<\/strong> no 1 l\u012bdz 500 mm\/min piel\u0101gotai test\u0113\u0161anai<\/li>\n\n\n\n<li><strong data-start=\"3154\" data-end=\"3206\">Augstas iz\u0161\u0137irtsp\u0113jas novirzes m\u0113r\u012bjumi (0,01 mm)<\/strong><\/li>\n\n\n\n<li><strong data-start=\"3211\" data-end=\"3234\">P\u0101rslodzes aizsardz\u012bba<\/strong> iek\u0101rtu un paraugu dro\u0161\u012bbai<\/li>\n\n\n\n<li><strong data-start=\"3271\" data-end=\"3300\">Autom\u0101tisk\u0101s atgrie\u0161an\u0101s funkcija<\/strong> p\u0113c testa<\/li>\n\n\n\n<li><strong data-start=\"3315\" data-end=\"3342\">Integr\u0113ts mikroprinteris<\/strong> t\u016bl\u012bt\u0113ja rezult\u0101tu dokument\u0113\u0161ana<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Testa principa un metodolo\u0123ijas skaidrojums<\/h2>\n\n\n\n<p>Stingruma testa princips ir vienk\u0101r\u0161s, bet zin\u0101tniski pamatots:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong data-start=\"3519\" data-end=\"3534\">Pozicion\u0113\u0161ana<\/strong>: \u0160\u013circes caurule abos galos ir balst\u012bta ISO 9626 2. tabul\u0101 noteiktaj\u0101 garum\u0101.<\/li>\n\n\n\n<li><strong data-start=\"3632\" data-end=\"3653\">Sp\u0113ka pieteikums<\/strong>: Virzu\u013ca virzulim ir lejupv\u0113rsts sp\u0113ks viduspunkt\u0101, ar \u0101truma kontroli (1-10 mm\/min ISO 9626 standartam; l\u012bdz 500 mm\/min piel\u0101gojamiem testiem).<\/li>\n\n\n\n<li><strong data-start=\"3805\" data-end=\"3831\">Novirzes m\u0113r\u012b\u0161ana<\/strong>: Instruments m\u0113ra caurules novirzi ar precizit\u0101ti \u00b10,01 mm.<\/li>\n\n\n\n<li><strong data-start=\"3908\" data-end=\"3926\">Datu ierakst\u012b\u0161ana<\/strong>: Tiek re\u0123istr\u0113ta un izdruk\u0101ta t\u0101da inform\u0101cija k\u0101 caurules izm\u0113rs, materi\u0101ls, deform\u0101cija, testa \u0101trums un pielietotais sp\u0113ks.<\/li>\n<\/ol>\n\n\n\n<p>\u0160is tests nodro\u0161ina atbilst\u012bbu gan ISO, gan iek\u0161\u0113jiem kvalit\u0101tes standartiem.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">K\u0101p\u0113c izv\u0113l\u0113ties Cell Instruments' TS-01 \u0161\u013circes caurul\u012btes stinguma testeri?<\/h2>\n\n\n\n<p>Cell Instruments ir izveidojis reput\u0101ciju, pateicoties precizit\u0101tei, atbilst\u012bbai un piel\u0101gojam\u012bbai. Port\u0101ls <strong data-start=\"4286\" data-end=\"4325\">TS-01 \u0161\u013circes caurul\u012btes stinguma testeris<\/strong> pied\u0101v\u0101 izcilu precizit\u0101ti un robustas funkcijas, kas piel\u0101gotas \u0161\u013cir\u010du ra\u017eo\u0161anai un kvalit\u0101tes laboratorij\u0101m. M\u016bsu komanda atbalsta ar\u012b <strong data-start=\"4450\" data-end=\"4482\">piel\u0101gotas test\u0113\u0161anas pras\u012bbas<\/strong> un <strong data-start=\"4487\" data-end=\"4511\">automatiz\u0101cijas risin\u0101jumi<\/strong>, nodro\u0161inot integr\u0101ciju ar eso\u0161aj\u0101m darba pl\u016bsm\u0101m iepakojuma, farm\u0101cijas un medic\u012bnas ier\u012b\u010du ra\u017eo\u0161an\u0101.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Lietojumprogrammas un apkalpojam\u0101s nozares<\/h2>\n\n\n\n<p>The <strong data-start=\"4671\" data-end=\"4704\">\u0160\u013circes caurules stinguma testeris<\/strong> tiek pla\u0161i izmantots vair\u0101k\u0101s nozar\u0113s:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"4749\" data-end=\"4781\">Medic\u012bnisko ier\u012b\u010du ra\u017eo\u0161ana<\/strong><\/li>\n\n\n\n<li><strong data-start=\"4786\" data-end=\"4815\">Farmaceitisk\u0101 ra\u017eo\u0161ana<\/strong><\/li>\n\n\n\n<li><strong data-start=\"4820\" data-end=\"4844\">Vesel\u012bbas apr\u016bpes iepakojums<\/strong><\/li>\n\n\n\n<li><strong data-start=\"4849\" data-end=\"4891\">Normat\u012bv\u0101s atbilst\u012bbas un test\u0113\u0161anas laboratorijas<\/strong><\/li>\n\n\n\n<li><strong data-start=\"4896\" data-end=\"4942\">Kvalit\u0101tes nodro\u0161in\u0101\u0161ana adatu ra\u017eot\u0101jiem<\/strong><\/li>\n<\/ul>\n\n\n\n<p>Neatkar\u012bgi no t\u0101, vai p\u0101rbaud\u0101t produktu dro\u0161\u012bbu, atbilstat <strong data-start=\"4994\" data-end=\"5014\"><a href=\"https:\/\/www.iso.org\/standard\/60480.html\" target=\"_blank\" rel=\"noopener nofollow\">ISO 9626<\/a> test\u0113\u0161ana<\/strong> krit\u0113rijus vai nodro\u0161inot meh\u0101nisko uzticam\u012bbu, TS-01 ir piem\u0113rots risin\u0101jums.<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>\u0160\u013cir\u010du caurul\u012b\u0161u stinguma testeris m\u0113ra ner\u016bs\u0113jo\u0161\u0101 t\u0113rauda adatu caurul\u012b\u0161u stingr\u012bbu, nodro\u0161ina uzticamu metodi kvalit\u0101tes kontrolei un standartu iev\u0113ro\u0161anai.<\/p>","protected":false},"featured_media":5367,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"product-category":[434,580,438,593,582],"product-tag":[],"class_list":["post-9586","products","type-products","status-publish","has-post-thumbnail","hentry","product-category-iso","product-category-iso-9626","product-category-medical-and-pharmaceutical-testing","product-category-syringe-testing","product-category-tube-stiffness-tester"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/products\/9586","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/types\/products"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/media\/5367"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/media?parent=9586"}],"wp:term":[{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/product-category?post=9586"},{"taxonomy":"product-tag","embeddable":true,"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/product-tag?post=9586"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}