{"id":9825,"date":"2026-02-24T15:11:44","date_gmt":"2026-02-24T07:11:44","guid":{"rendered":"https:\/\/www.packqc.com\/standard\/iso-9626\/"},"modified":"2026-04-16T09:54:22","modified_gmt":"2026-04-16T01:54:22","slug":"iso-9626","status":"publish","type":"standard","link":"https:\/\/www.packqc.com\/lv\/standard\/iso-9626\/","title":{"rendered":"ISO 9626"},"content":{"rendered":"<p><\/p>\n\n\n\n<h1 class=\"wp-block-heading\">ISO 9626<\/h1>\n\n\n\n<h2 class=\"wp-block-heading\">Kas ir ISO 9626?<\/h2>\n\n\n\n<p>Taj\u0101 sniegtas standartiz\u0113tas specifik\u0101cijas ner\u016bs\u0113jo\u0161\u0101 t\u0113rauda caurul\u0113m, ko izmanto medic\u012bnisko adatu ra\u017eo\u0161an\u0101, s\u0101kot no 3,4 mm (10 mm) l\u012bdz 0,18 mm (34 mm). Standarts attiecas tikai uz cietaj\u0101m caurul\u0113m, iz\u0146emot elast\u012bgos variantus at\u0161\u0137ir\u012bgu meh\u0101nisko \u012bpa\u0161\u012bbu d\u0113\u013c.<\/p>\n\n\n\n<p>ISO 9626 aptver \u0161\u0101das galven\u0101s jomas:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><b>Izm\u0113ru pielaides<\/b> ner\u016bs\u0113jo\u0161\u0101 t\u0113rauda adatu caurul\u012btes<\/li>\n\n\n\n<li>Meh\u0101nisk\u0101s \u012bpa\u0161\u012bbas, piem. <b>stingr\u012bba un iztur\u012bba pret l\u016b\u0161anu<\/b><\/li>\n\n\n\n<li><b>Iztur\u012bba pret koroziju<\/b> simul\u0113tos fiziolo\u0123iskos apst\u0101k\u013cos<\/li>\n\n\n\n<li>Ekstraktu sagatavo\u0161ana un nov\u0113rt\u0113\u0161ana biosader\u012bbas test\u0113\u0161anai<\/li>\n<\/ul>\n\n\n\n<p>Standarts ir b\u016btisks ra\u017eot\u0101jiem, kas ra\u017eo adatas injekcij\u0101m, \u0161\u0137idrumu paraugu \u0146em\u0161anai un citiem medic\u012bniskiem lietojumiem. T\u0101 iev\u0113ro\u0161ana nodro\u0161ina darb\u012bbas konsekvenci, pacientu dro\u0161\u012bbu un atbilst\u012bbu pasaules regulat\u012bvaj\u0101m iest\u0101d\u0113m.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u0160\u013circes adatas test\u0113\u0161ana saska\u0146\u0101 ar ISO 9626<\/h2>\n\n\n\n<p>Standart\u0101 ISO 9626 ir aprakst\u012btas vair\u0101kas b\u016btiskas \u0161\u013cir\u010du adatu test\u0113\u0161anas proced\u016bras, kas apstiprina adatu cauru\u013cu meh\u0101nisko integrit\u0101ti un iztur\u012bbu:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Injekcijas adatas stinguma tests<\/h3>\n\n\n\n<p>\u0160aj\u0101 test\u0101 tiek nov\u0113rt\u0113ta adatas caurules stingr\u012bba kontrol\u0113tas slodzes apst\u0101k\u013cos. Proced\u016bra ietver:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Caurules balst\u012b\u0161ana uz garenvirziena, ko nosaka t\u0101s gabar\u012bts.<\/li>\n\n\n\n<li>Lejupv\u0113rsta sp\u0113ka pielik\u0161ana, izmantojot virzuli ar noteiktu \u0123eometriju<\/li>\n\n\n\n<li>Deform\u0101cijas m\u0113r\u012b\u0161ana centr\u0101, lai nov\u0113rt\u0113tu stingr\u012bbu<\/li>\n<\/ul>\n\n\n\n<p>P\u0101rm\u0113r\u012bga elast\u012bba var izrais\u012bt sliktu apstr\u0101di vai neprec\u012bzu injekciju veik\u0161anu. Ra\u017eot\u0101jiem j\u0101nodro\u0161ina, lai adata saglab\u0101tu meh\u0101nisko stabilit\u0101ti paredzamajos kl\u012bnisk\u0101s lieto\u0161anas apst\u0101k\u013cos.<\/p>\n\n\n\n<p>Cell Instruments\u2019 TS-01 adatu cauru\u013cu stinguma testeris ir optimiz\u0113ts \u0161im lietojumam. Tas pied\u0101v\u0101:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u00b10,1 N sp\u0113ka precizit\u0101te<\/li>\n\n\n\n<li>Mikronu l\u012bme\u0146a novirzes m\u0113r\u012bjumi<\/li>\n\n\n\n<li>Piel\u0101gojami diapazona iestat\u012bjumi atbilsto\u0161i m\u0113rinstrumenta specifik\u0101cijai<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Adatas p\u0101rr\u0101vuma pretest\u012bbas tests<\/h3>\n\n\n\n<p>Iztur\u012bba pret p\u0101rr\u0101vumiem ir b\u016btiska, lai nov\u0113rstu cauru\u013cu boj\u0101jumus lieto\u0161anas laik\u0101. ISO 9626 nosaka ciklisko lieces testu, kur\u0101 caurul\u0113m veic l\u012bdz 20 main\u012bgiem lieces le\u0146\u0137iem noteikt\u0101 le\u0146\u0137\u012b:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Caurules ar parast\u0101m sieni\u0146\u0101m: (25 \u00b11)\u00b0.<\/li>\n\n\n\n<li>Pl\u0101nsienu caurules: (20 \u00b11)\u00b0.<\/li>\n\n\n\n<li>\u012apa\u0161i pl\u0101nas\/ultra-pl\u0101nas sienas: (15 \u00b11)\u00b0<\/li>\n<\/ul>\n\n\n\n<p>\u0160is tests pal\u012bdz nov\u0113rt\u0113t iztur\u012bbu pret nogurumu atk\u0101rtotas slodzes apst\u0101k\u013cos. Redzams l\u016bzums nor\u0101da uz boj\u0101jumu.<\/p>\n\n\n\n<p>Cell Instruments\u2019 NTT-01 adatu cauru\u013cu p\u0101rr\u0101vuma pretest\u012bbas testeris veic \u0161o testu ar:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Programm\u0113jami lieces le\u0146\u0137i un cikli<\/li>\n\n\n\n<li>Vizu\u0101l\u0101s p\u0101rbaudes \u0137erme\u0146i<\/li>\n\n\n\n<li>Regul\u0113jams stiprin\u0101jums da\u017e\u0101diem cauru\u013cu diametriem<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Iztur\u012bbas pret koroziju nov\u0113rt\u0113jums<\/h3>\n\n\n\n<p>ISO 9626 D pielikums attiecas uz iztur\u012bbu pret koroziju, nodro\u0161inot, ka adatas nesaboj\u0101jas saskar\u0113 ar \u0137erme\u0146a \u0161\u0137idrumiem. Ner\u016bs\u0113jo\u0161\u0101 t\u0113rauda caurul\u012bt\u0113m ir j\u0101b\u016bt iztur\u012bg\u0101m pret punkt\u0113jumu un r\u016bsas veido\u0161anos p\u0113c iegremd\u0113\u0161anas testa \u0161\u0137\u012bdumos, piem\u0113ram, fiziolo\u0123iskaj\u0101 \u0161\u0137\u012bdum\u0101.<\/p>\n\n\n\n<p>Lai gan tas ne vienm\u0113r ir oblig\u0101ti, daudzi ra\u017eot\u0101ji, lai mazin\u0101tu risku, iek\u013cauj iztur\u012bbu pret koroziju \u0161\u013cir\u010du adatu regul\u0101ro p\u0101rbau\u017eu ietvaros.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Papildu ISO 9626 test\u0113\u0161anas apsv\u0113rumi<\/h3>\n\n\n\n<p>Papildus galvenajiem meh\u0101niskajiem nov\u0113rt\u0113jumiem ISO 9626 nosaka ar\u012b:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Prec\u012bzi izm\u0113ru m\u0113r\u012bjumi<\/li>\n\n\n\n<li>Sienas tipa identifik\u0101cija (RW, TW, ETW, UTW)<\/li>\n\n\n\n<li>Sakaus\u0113jumu klasifik\u0101cija saska\u0146\u0101 ar ISO 15510 vai ASTM A959.<\/li>\n\n\n\n<li>Testa dokument\u0101cija, tostarp m\u0113rier\u012bces izm\u0113rs, deform\u0101cijas v\u0113rt\u012bbas un testa apst\u0101k\u013ci.<\/li>\n<\/ul>\n\n\n\n<p>Prec\u012bza test\u0113\u0161ana ne tikai atbilst atbilst\u012bbas pras\u012bb\u0101m, bet ar\u012b stiprina produkta uzticam\u012bbu un z\u012bmola reput\u0101ciju.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">ISO 9626 test\u0113\u0161ana - b\u016btiska \u0161\u013cir\u010du kvalit\u0101tes kontrolei<\/h2>\n\n\n\n<p>ISO 9626 standartu neiev\u0113ro\u0161ana var izrais\u012bt:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Adatas saliek\u0161an\u0101s vai l\u016bzums injekcijas laik\u0101<\/li>\n\n\n\n<li>Nekonssekventa \u0161\u0137idruma pieg\u0101de<\/li>\n\n\n\n<li>Paaugstin\u0101ts pacientu traumu risks<\/li>\n\n\n\n<li>Neatbilst\u012bba normat\u012bvo aktu pras\u012bb\u0101m un atsaukumi<\/li>\n<\/ul>\n\n\n\n<p>Integr\u0113jot ISO 9626 pras\u012bb\u0101m atbilsto\u0161u \u0161\u013cir\u010du adatu test\u0113\u0161anu, ra\u017eot\u0101ji un kvalit\u0101tes nodro\u0161in\u0101\u0161anas komandas:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Meh\u0101nisk\u0101s iztur\u012bbas un ilgiztur\u012bbas apstiprin\u0101\u0161ana<\/li>\n\n\n\n<li>Atbilst\u012bbas nodro\u0161in\u0101\u0161ana normat\u012bvaj\u0101m pras\u012bb\u0101m<\/li>\n\n\n\n<li>Samazin\u0101t atbild\u012bbu un produktu k\u013c\u016bmju \u012bpatsvaru<\/li>\n\n\n\n<li>Uzlabot klientu uztic\u0113\u0161anos un apmierin\u0101t\u012bbu<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">ISO 9626 test\u0113\u0161anas risin\u0101juma izv\u0113le<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.packqc.com\/lv\/product\/syringe-tube-stiffness-tester\/\" target=\"_blank\"><img decoding=\"async\" src=\"https:\/\/www.packqc.com\/wp-content\/uploads\/2025\/05\/Syringe-Tube-Stiffness-Tester-ISO-9626-Annex-B.webp\" alt=\"TS-01 \u0160\u013circes caurul\u012btes stinguma testeris - ISO 9626 B pielikums\"\/><\/a><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\"><a href=\"https:\/\/www.packqc.com\/lv\/product\/syringe-tube-stiffness-tester\/\" target=\"_blank\">TS-01 \u0161\u013circes adatas stinguma testeris<\/a><\/h3>\n\n\n\n<p>Lai prec\u012bzi nov\u0113rt\u0113tu ner\u016bs\u0113jo\u0161\u0101 t\u0113rauda adatu caurul\u012b\u0161u stinguma \u012bpa\u0161\u012bbas, k\u0101 noteikts ISO 9626 B pielikum\u0101, Cell Instruments \u0161\u013cir\u010du adatu stinguma testeris TS-01 ir uzticams un prec\u012bzs risin\u0101jums. \u0160is instruments nodro\u0161ina konsekventu sp\u0113ka pielieto\u0161anu un prec\u012bzu caurul\u012b\u0161u deform\u0101cijas m\u0113r\u012b\u0161anu, pal\u012bdzot ra\u017eot\u0101jiem un kvalit\u0101tes kontroles komand\u0101m izpild\u012bt normat\u012bvo aktu pras\u012bbas attiec\u012bb\u0101 uz injekciju adatu stinguma test\u0113\u0161anu.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.packqc.com\/lv\/product\/needle-toughness-tester\/\" target=\"_blank\"><img decoding=\"async\" src=\"https:\/\/www.packqc.com\/wp-content\/uploads\/2025\/04\/Needle-Toughness-Tester-ISO-9626-Breakage-Resistance-Test.webp\" alt=\"NTT-01 adatu iztur\u012bbas testeris - ISO 9626 iztur\u012bbas pret salau\u0161anu tests\"\/><\/a><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\"><a href=\"https:\/\/www.packqc.com\/lv\/product\/needle-toughness-tester\/\" target=\"_blank\">NTT-01 adatas p\u0101rr\u0101vuma pretest\u012bbas testeris<\/a><\/h3>\n\n\n\n<p>Medic\u012bnisko adatu caurul\u012b\u0161u meh\u0101nisk\u0101s iztur\u012bbas nov\u0113rt\u0113\u0161anai, pak\u013caujot t\u0101s atk\u0101rtotai lieces sp\u0113ka iedarb\u012bbai saska\u0146\u0101 ar ISO 9626 C pielikumu, NTT-01 adatu p\u0101rr\u0101vuma iztur\u012bbas testeris ir svar\u012bgs instruments. \u0160is testeris, kas paredz\u0113ts stingrai kvalit\u0101tes nodro\u0161in\u0101\u0161anai, imit\u0113 re\u0101lus lieto\u0161anas apst\u0101k\u013cus un sniedz prec\u012bzus datus par caurul\u012b\u0161u elast\u012bbu un struktur\u0101lo integrit\u0101ti, kas ir kritiski svar\u012bgi, lai nov\u0113rstu adatu boj\u0101jumus kl\u012bnisk\u0101s lieto\u0161anas laik\u0101.<\/p>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\n\t\t\t\tSazinieties ar mums Ieg\u016bstiet ISO 9626 test\u0113\u0161anas risin\u0101jumu\t\t\t\t<\/h2>\n\n\n\n<p><strong>ISO 9626<\/strong> ir b\u016btiska noz\u012bme <strong>\u0161\u013cir\u010du adatu test\u0113\u0161ana<\/strong> nosakot krit\u0113rijus<strong> stingr\u012bba, iztur\u012bba pret p\u0101rr\u0101vumiem un visp\u0101r\u0113j\u0101 struktur\u0101l\u0101 integrit\u0101te.<\/strong> ner\u016bs\u0113jo\u0161\u0101 t\u0113rauda adatu caurul\u012btes. Veicot prec\u012bzus meh\u0101niskos nov\u0113rt\u0113jumus, ra\u017eot\u0101ji var nodro\u0161in\u0101t, ka vi\u0146u izstr\u0101d\u0101jumi atbilst gan normat\u012bvaj\u0101m, gan funkcion\u0101laj\u0101m pras\u012bb\u0101m.<\/p>\n\n\n\n<p>Cell Instruments TS-01 un NTT-01 testeri pied\u0101v\u0101 visaptvero\u0161u, ISO pras\u012bb\u0101m atbilsto\u0161u risin\u0101jumu, kas atbilst main\u012bgaj\u0101m medic\u012bnas ier\u012b\u010du kvalit\u0101tes kontroles pras\u012bb\u0101m. Ieguldiet l\u012bdzek\u013cus lab\u0101kai atbilst\u012bbai, samazin\u0101tam riskam un izcilai veiktsp\u0113jai ar Cell Instruments k\u0101 savu partneri \u0161\u013cir\u010du adatu test\u0113\u0161an\u0101.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">FAQ<\/h2>\n\n\n\n<p>1. K\u0101ds ir standarta galvenais m\u0113r\u0137is?<br>ISO 9626 nosaka izm\u0113ru un meh\u0101nisk\u0101s pras\u012bbas ner\u016bs\u0113jo\u0161\u0101 t\u0113rauda ner\u016bs\u0113jo\u0161\u0101 t\u0113rauda adatu caurul\u0113m, ko izmanto medic\u012bnas ier\u012bc\u0113s, lai nodro\u0161in\u0101tu dro\u0161\u012bbu un veiktsp\u0113ju.<\/p>\n\n\n\n<p>2. K\u0101dus testu veidus aptver ISO 9626?<br>Testi ietver injekcijas adatas stingr\u012bbas, adatas iztur\u012bbas pret l\u016b\u0161anu, iztur\u012bbas pret koroziju un ekstrakta sagatavo\u0161anu biosader\u012bbas nov\u0113rt\u0113\u0161anai.<\/p>\n\n\n\n<p>3. K\u0101di ir RW, TW, ETW un UTW cauru\u013cu veidi?<br>Tie attiecas uz sienu biezuma kategorij\u0101m: Tie ir parast\u0101s sienas (RW), pl\u0101n\u0101s sienas (TW), \u012bpa\u0161i pl\u0101n\u0101s sienas (ETW) un \u012bpa\u0161i pl\u0101n\u0101s sienas (UTW), kas nosaka testa parametrus un lieces le\u0146\u0137us.<\/p>\n\n\n\n<p>4. K\u0101 Cell Instruments apr\u012bkojums var pal\u012bdz\u0113t ISO 9626 test\u0113\u0161an\u0101?<br>Cell Instruments\u2019 TS-01 un NTT-01 nodro\u0161ina prec\u012bzus, atk\u0101rtojamus stingr\u012bbas un iztur\u012bbas pret p\u0101rr\u0101vumiem test\u0113\u0161anas nosac\u012bjumus, pal\u012bdzot ra\u017eot\u0101jiem nodro\u0161in\u0101t atbilst\u012bbu <a href=\"https:\/\/www.iso.org\/standard\/60480.html\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">ISO 9626<\/a> standartiem.<\/p>\n\n\n\n<p>5. K\u0101p\u0113c ir svar\u012bgi p\u0101rbaud\u012bt adatu p\u0101rr\u0101vuma pretest\u012bbu?<br>Tas nodro\u0161ina, ka lieto\u0161anas laik\u0101 adata slodzes ietekm\u0113 nesal\u016bz\u012bs, t\u0101d\u0113j\u0101di nov\u0113r\u0161ot ier\u012bces boj\u0101jumus un pacienta traumas.<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>ISO 9626 What is ISO 9626? It provides standardized specifications for stainless steel tubing used in the manufacture of medical needles, ranging from 3.4 mm (10 Gauge) down to 0.18 mm (34 Gauge). The standard applies only to rigid tubing, excluding flexible variants due to differing mechanical behaviors. Key areas covered by ISO 9626 include: [&hellip;]<\/p>","protected":false},"featured_media":5377,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"standard-category":[612],"class_list":["post-9825","standard","type-standard","status-publish","has-post-thumbnail","hentry","standard-category-iso"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/standard\/9825","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/standard"}],"about":[{"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/types\/standard"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/media\/5377"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/media?parent=9825"}],"wp:term":[{"taxonomy":"standard-category","embeddable":true,"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/standard-category?post=9825"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}