{"id":9857,"date":"2026-02-24T15:11:45","date_gmt":"2026-02-24T07:11:45","guid":{"rendered":"https:\/\/www.packqc.com\/standard\/astm-f2338-2\/"},"modified":"2026-04-16T09:53:23","modified_gmt":"2026-04-16T01:53:23","slug":"astm-f2338","status":"publish","type":"standard","link":"https:\/\/www.packqc.com\/lv\/standard\/astm-f2338\/","title":{"rendered":"ASTM F2338"},"content":{"rendered":"<p>ASTM F2338 noz\u012bme iepakojuma kvalit\u0101t\u0113<\/p>\n\n\n\n<p>Iepakojums kalpo k\u0101 pirm\u0101 barjera pret pies\u0101r\u0146ojumu. Pat mikroskopiskas nopl\u016bdes bl\u012bv\u0113s vai materi\u0101los var izrais\u012bt sk\u0101bek\u013ca, mitruma vai mikroorganismu iek\u013c\u016b\u0161anu. Farmaceitiskiem produktiem viena neatkl\u0101ta nopl\u016bde var apdraud\u0113t pacientu dro\u0161\u012bbu. ASTM F2338 risina \u0161o probl\u0113mu, pied\u0101v\u0101jot <strong data-start=\"1180\" data-end=\"1237\">valid\u0113ta, nesagraujo\u0161a un atk\u0101rtojama test\u0113\u0161anas metode.<\/strong> kas p\u0101rsniedz tradicion\u0101l\u0101s destrukt\u012bv\u0101s metodes, piem\u0113ram, kr\u0101su iek\u013c\u016b\u0161anu vai burbu\u013cu emisiju.<\/p>\n\n\n\n<p>\u0160is standarts ir \u012bpa\u0161i v\u0113rt\u012bgs <strong data-start=\"1370\" data-end=\"1411\">farm\u0101cijas iepakojuma nopl\u016bdes noteik\u0161ana<\/strong>, kur regulat\u012bv\u0101s iest\u0101des uzsver, ka ir vajadz\u012bgas prec\u012bzas, neinvaz\u012bvas metodes, kas \u013cauj saglab\u0101t p\u0101rbaud\u012btos paraugus turpm\u0101kai izmanto\u0161anai vai izplat\u012b\u0161anai.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">K\u0101 darbojas vakuuma sabruk\u0161anas metode<\/h2>\n\n\n\n<p>ASTM F2338 metode ir balst\u012bta uz prec\u012bzu <strong data-start=\"1642\" data-end=\"1690\">spiediena monitorings herm\u0113tisk\u0101 testa kamer\u0101<\/strong>. \u0160eit ir aprakst\u012bts vienk\u0101r\u0161s process:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Iepakojumu ievieto stingr\u0101 testa kamer\u0101.<\/li>\n\n\n\n<li>Tiek izveidots vakuums, un kamera tiek izol\u0113ta no avota.<\/li>\n\n\n\n<li>Augstas iz\u0161\u0137irtsp\u0113jas spiediena dev\u0113ji m\u0113ra jebkuru spiediena pieaugumu laika gait\u0101.<\/li>\n\n\n\n<li>Spiediena palielin\u0101\u0161an\u0101s nor\u0101da uz g\u0101zes nopl\u016bdi no iepakojuma nopl\u016bdes d\u0113\u013c.<\/li>\n<\/ul>\n\n\n\n<p>At\u0161\u0137ir\u012bb\u0101 no vizu\u0101l\u0101s p\u0101rbaudes vai kr\u0101su test\u0113\u0161anas, vakuuma sabruk\u0161anas metode ir <strong data-start=\"2085\" data-end=\"2169\">kvantitat\u012bvs, jut\u012bgs, un nav nepiecie\u0161ams main\u012bt vai izn\u012bcin\u0101t iepakojumu.<\/strong>. Ar pareizi kalibr\u0113t\u0101m sist\u0113m\u0101m t\u0101 var noteikt nopl\u016bdes l\u012bdz pat da\u017eu mikronu lielumam.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Nesagraujo\u0161as nopl\u016bdes noteik\u0161anas lietojumi<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Farmaceitisko iepakojumu nopl\u016bdes noteik\u0161ana<\/h3>\n\n\n\n<p>Steril\u0101 farmaceitisk\u0101 iepakojum\u0101, piem\u0113ram, flakonos, \u0161\u013circi\u0146\u0101s vai blisteros, ASTM F2338 nodro\u0161ina, ka <strong data-start=\"2473\" data-end=\"2510\">konteinera nosl\u0113guma integrit\u0101te (CCI)<\/strong>. Nov\u0113r\u0161ot kait\u012bgo mikrobu iek\u013c\u016b\u0161anu, metodei ir b\u016btiska noz\u012bme normat\u012bvo pras\u012bbu iev\u0113ro\u0161an\u0101.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">P\u0101rtikas un dz\u0113rienu iepakojuma integrit\u0101tes test\u0113\u0161ana<\/h3>\n\n\n\n<p>Vakuum\u0101 iepakotiem p\u0101rtikas produktiem, elast\u012bgiem maisi\u0146iem vai papl\u0101t\u0113m ar v\u0101ku herm\u0113tiska nosl\u0113guma nodro\u0161in\u0101\u0161ana ir b\u016btiska produktu dro\u0161\u012bbai un ilg\u0101kam der\u012bguma termi\u0146am. ASTM F2338 pied\u0101v\u0101 efekt\u012bvu veidu, k\u0101 veikt testus, nezaud\u0113jot produktu.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Medic\u012bnisko ier\u012b\u010du iepakojums<\/h3>\n\n\n\n<p>Medic\u012bniskajiem papl\u0101t\u0113m, maisi\u0146iem un barjeras iepakojumiem j\u0101paliek neskartiem l\u012bdz lieto\u0161anas vietai. Nesagraujo\u0161a nopl\u016bdes noteik\u0161ana nodro\u0161ina \u0161o iepakojumu atbilst\u012bbu stingriem kvalit\u0101tes standartiem.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">ASTM F2338 priek\u0161roc\u012bbas sal\u012bdzin\u0101jum\u0101 ar cit\u0101m metod\u0113m<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"3152\" data-end=\"3170\">Nedestrukt\u012bvais<\/strong> - Paraugi paliek neskarti, un tos var atgriezt ra\u017eo\u0161an\u0101.<\/li>\n\n\n\n<li><strong data-start=\"3234\" data-end=\"3254\">\u013boti jut\u012bgs<\/strong> - Atkl\u0101j nopl\u016bdes, kas ir maz\u0101kas, nek\u0101 var noteikt ar vizu\u0101l\u0101m metod\u0113m.<\/li>\n\n\n\n<li><strong data-start=\"3317\" data-end=\"3341\">Kvantitat\u012bvie rezult\u0101ti<\/strong> - Nodro\u0161ina izm\u0113r\u0101mus datus, nevis subjekt\u012bvu vizu\u0101lu apstiprin\u0101jumu.<\/li>\n\n\n\n<li><strong data-start=\"3417\" data-end=\"3442\">Normat\u012bv\u0101 pie\u0146em\u0161ana<\/strong> - Pla\u0161i atz\u012bta farm\u0101cijas un medic\u012bnas ier\u012b\u010du nozar\u0113.<\/li>\n\n\n\n<li><strong data-start=\"3520\" data-end=\"3538\">Rentabls<\/strong> - Nov\u0113r\u0161 materi\u0101lu atkritumus, kas rodas destrukt\u012bvo p\u0101rbau\u017eu laik\u0101.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">ASTM F2338 test\u0113\u0161anai nepiecie\u0161am\u0101 apr\u012bkojuma izv\u0113le<\/h2>\n\n\n\n<p>\u012astenot <a href=\"https:\/\/www.astm.org\/f2338-09r20.html\" target=\"_blank\" rel=\"noopener nofollow\">ASTM F2338<\/a> efekt\u012bvi, ir nepiecie\u0161ami prec\u012bzi instrumenti. Port\u0101ls <strong data-start=\"3731\" data-end=\"3781\">MLT-01 <a href=\"https:\/\/www.packqc.com\/lv\/products\/mlt-01-vacuum-decay-leak-test-equipment\/\" target=\"_blank\" rel=\"noreferrer noopener\">Mikro nopl\u016bdes testeris<\/a> no Cell Instruments<\/strong> ir \u012bpa\u0161i izstr\u0101d\u0101ts, lai <strong data-start=\"3811\" data-end=\"3835\">vakuuma sabruk\u0161anas test\u0113\u0161ana<\/strong>. MLT-01 ar augstas jut\u012bbas sensoriem, piel\u0101gojamiem kameru izm\u0113riem un lietot\u0101jam draudz\u012bgu PLC vad\u012bbas sist\u0113mu nodro\u0161ina uzticamus rezult\u0101tus visda\u017e\u0101d\u0101kajiem iepakojumu tipiem.<\/p>\n\n\n\n<p>Uz\u0146\u0113mumi, kas nodarbojas ar <strong data-start=\"4034\" data-end=\"4111\">farm\u0101cijas iepakojuma nopl\u016bdes noteik\u0161ana vai p\u0101rtikas iepakojuma integrit\u0101tes p\u0101rbaude.<\/strong> g\u016bs labumu no instrumenta sp\u0113jas atkl\u0101t nelielas nopl\u016bdes, vienlaikus saglab\u0101jot produktivit\u0101ti. Integr\u0113jot \u0161\u0101du modernu apr\u012bkojumu, ra\u017eot\u0101ji stiprina kvalit\u0101tes nodro\u0161in\u0101\u0161anu un atbilst\u012bbu starptautiskajiem standartiem.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Sazinieties ar mums Ieg\u016bstiet ASTM F2338 test\u0113\u0161anas risin\u0101jumu <\/h2>\n\n\n\n<p><a href=\"https:\/\/store.astm.org\/f2338-24.html\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">ASTM F2338<\/a> nodro\u0161ina uzticamu, valid\u0113tu pieeju, lai <strong data-start=\"4897\" data-end=\"4931\">nesagraujo\u0161a nopl\u016bdes noteik\u0161ana<\/strong> iesai\u0146o\u0161anai. Izmantojot vakuuma sabruk\u0161anas metodi, ra\u017eot\u0101ji nodro\u0161ina, ka <strong data-start=\"5007\" data-end=\"5053\">farm\u0101cijas, medic\u012bnas un p\u0101rtikas produktu iepakojumi<\/strong> saglab\u0101t dro\u0161u un neskartu vis\u0101 to dz\u012bves cikl\u0101. Izmantojot progres\u012bvus risin\u0101jumus, piem. <strong data-start=\"5141\" data-end=\"5186\">Cell Instruments MLT-01 mikro nopl\u016bdes testeris<\/strong>, uz\u0146\u0113mumi var pan\u0101kt konsekventu, jut\u012bgu un efekt\u012bvu. <strong data-start=\"5247\" data-end=\"5278\">iepakojuma integrit\u0101tes p\u0101rbaude<\/strong> saska\u0146\u0101 ar pasaules kvalit\u0101tes standartiem.<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Importance of ASTM F2338 in Packaging Quality Packaging serves as the first barrier against contamination. Even microscopic leaks in seals or materials can allow the ingress of oxygen, moisture, or microorganisms. For pharmaceutical products, a single undetected leak may compromise patient safety. ASTM F2338 addresses this issue by offering a validated, nondestructive, and repeatable test [&hellip;]<\/p>","protected":false},"featured_media":7869,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"standard-category":[611],"class_list":["post-9857","standard","type-standard","status-publish","has-post-thumbnail","hentry","standard-category-astm"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/standard\/9857","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/standard"}],"about":[{"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/types\/standard"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/media\/7869"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/media?parent=9857"}],"wp:term":[{"taxonomy":"standard-category","embeddable":true,"href":"https:\/\/www.packqc.com\/lv\/wp-json\/wp\/v2\/standard-category?post=9857"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}