{"id":9580,"date":"2026-02-02T14:53:24","date_gmt":"2026-02-02T06:53:24","guid":{"rendered":"https:\/\/www.packqc.com\/products\/needle-penetration-test-equipment-iso-7864\/"},"modified":"2026-04-16T10:33:56","modified_gmt":"2026-04-16T02:33:56","slug":"needle-penetration-test-equipment-iso-7864","status":"publish","type":"products","link":"https:\/\/www.packqc.com\/nn\/products\/needle-penetration-test-equipment-iso-7864\/","title":{"rendered":"Needle Penetration Test Equipment for ISO 7864 Testing"},"content":{"rendered":"<p>Needle penetration test equipment is a critical tool for evaluating the sharpness and performance of medical needles. This testing is essential in ensuring compliance with industry standards, such as <strong>ISO 7864 testing<\/strong>, which governs the quality of sterile hypodermic needles. The test measures key parameters such as <strong>penetrability test<\/strong> force and drag force to assess the needle\u2019s effectiveness in piercing biological materials.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Key of ISO 7864 Testing<\/h2>\n\n\n\n<p>ISO 7864 is the standard for hypodermic needles used in medical applications. It specifies requirements for performance, safety, and <strong>penetrability test<\/strong> procedures to ensure patient safety and ease of use. The penetration force and drag force are measured as the needle moves through a standardized substrate, replicating real-life injection scenarios.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Test Principle<\/h3>\n\n\n\n<p>The <strong>needle penetration test equipment<\/strong> evaluates the force required to insert a needle into a substrate at a controlled speed. The force gauge records resistance throughout penetration and withdrawal, providing insights into:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Initial penetration force<\/strong> \u2013 the force required to pierce the material.<\/li>\n\n\n\n<li><strong>Drag force region<\/strong> \u2013 the resistance as the needle moves through the substrate.<\/li>\n\n\n\n<li><strong>Penetration depth<\/strong> \u2013 the displacement of the needle as force is applied.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">How the Penetrability Test is Conducted<\/h2>\n\n\n\n<p>To ensure consistency and repeatability, the <strong>penetrability test<\/strong> follows these standardized steps:<\/p>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li><strong>Sample Preparation<\/strong> \u2013 The test samples and substrates are conditioned for at least 24 hours at laboratory conditions:\n<ul class=\"wp-block-list\">\n<li>Temperature: <strong>18\u00b0C to 28\u00b0C<\/strong><\/li>\n\n\n\n<li>Humidity: <strong>25%RH to 75%RH<\/strong><\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Test Setup<\/strong> \u2013 The needle is mounted on the force measurement apparatus, ensuring alignment perpendicular to the substrate.<\/li>\n\n\n\n<li><strong>Penetration Process<\/strong> \u2013 The needle moves at a controlled speed to pierce the substrate until the required penetration depth is achieved.<\/li>\n\n\n\n<li><strong>Force Measurement<\/strong> \u2013 The equipment records force data during insertion and withdrawal.<\/li>\n\n\n\n<li><strong>Result Calculation<\/strong> \u2013 Mean and standard deviation of penetration and drag forces are computed based on the sample size.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">Key Features of High-Quality Needle Penetration Test Equipment<\/h2>\n\n\n\n<p>For reliable <strong>ISO 7864 testing<\/strong>, <strong>needle penetration test equipment<\/strong> should include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>High-precision load cell<\/strong> to measure penetration and drag forces.<\/li>\n\n\n\n<li><strong>Adjustable penetration depth<\/strong> for versatile testing applications.<\/li>\n\n\n\n<li><strong>Automated alignment system<\/strong> to prevent misalignment errors.<\/li>\n\n\n\n<li><strong>Real-time data acquisition<\/strong> for accurate analysis.<\/li>\n\n\n\n<li><strong>User-friendly interface<\/strong> for simplified operation and reporting.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Main Parameter<\/h3>\n\n\n\n<p>Main Parameter &#8211; <a href=\"https:\/\/www.packqc.com\/nn\/product\/npt-01-needle-penetrability-tester\/\">Needle penetration test equipment<\/a><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Technical Feature<\/h3>\n\n\n\n<p>Technical Feature &#8211; <a href=\"https:\/\/www.packqc.com\/nn\/product\/npt-01-needle-penetrability-tester\/\">Needle penetration test equipment<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Choosing the Right Needle Penetration Test Equipment<\/h2>\n\n\n\n<p>Selecting suitable <strong>needle penetration test equipment<\/strong> involves evaluating:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Testing accuracy and precision<\/strong> \u2013 Essential for reliable compliance.<\/li>\n\n\n\n<li><strong>Equipment versatility<\/strong> \u2013 Should accommodate different needle sizes and materials.<\/li>\n\n\n\n<li><strong>Software integration<\/strong> \u2013 For seamless data analysis and storage.<\/li>\n\n\n\n<li><strong>Durability and maintenance<\/strong> \u2013 Ensures long-term performance with minimal downtime.<\/li>\n<\/ul>\n\n\n\n<p>Needle penetration testing is a fundamental part of medical device quality control. High-precision <strong>needle penetration test equipment<\/strong> ensures compliance with <strong><a href=\"https:\/\/www.iso.org\/standard\/60481.html\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">ISO 7864<\/a> testing<\/strong> and enhances the overall safety and effectiveness of medical needles. By selecting the right testing instruments, manufacturers can improve product performance and patient experience while meeting stringent regulatory standards.<\/p>","protected":false},"excerpt":{"rendered":"<p>Needle penetration test equipment measures penetrability test force and drag force to assess the needle\u2019s effectiveness in piercing biological materials.<\/p>","protected":false},"featured_media":5188,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"product-category":[434,574,438,495,593],"product-tag":[],"class_list":["post-9580","products","type-products","status-publish","has-post-thumbnail","hentry","product-category-iso","product-category-iso-7864","product-category-medical-and-pharmaceutical-testing","product-category-pharmaceutical-testing","product-category-syringe-testing"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/products\/9580","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/types\/products"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/media\/5188"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/media?parent=9580"}],"wp:term":[{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/product-category?post=9580"},{"taxonomy":"product-tag","embeddable":true,"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/product-tag?post=9580"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}