{"id":9582,"date":"2026-02-02T14:53:24","date_gmt":"2026-02-02T06:53:24","guid":{"rendered":"https:\/\/www.packqc.com\/products\/needle-toughness-tester\/"},"modified":"2026-04-16T10:11:17","modified_gmt":"2026-04-16T02:11:17","slug":"needle-toughness-tester","status":"publish","type":"products","link":"https:\/\/www.packqc.com\/nn\/products\/needle-toughness-tester\/","title":{"rendered":"NTT-01 Needle Toughness Tester"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Introduction to Needle Resistance to Breakage<\/h2>\n\n\n\n<p>Ensuring <em data-start=\"453\" data-end=\"484\">needle resistance to breakage<\/em> is a critical part of medical device safety and reliability, particularly for hypodermic needles. Breakage during use can lead to serious injury, contamination, or product failure. The <strong data-start=\"720\" data-end=\"754\">NTT-01 Needle Toughness Tester<\/strong> by Cell Instruments offers a precise, <b>ISO 9626 <\/b>solution for verifying the mechanical strength of stainless-steel needle tubing.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Why Needle Resistance to Breakage Testing Matters<\/h2>\n\n\n\n<p>In the realm of medical device manufacturing, especially for needles and catheters, mechanical failure during use poses significant risks. <em data-start=\"1443\" data-end=\"1474\">Needle resistance to breakage<\/em> must be validated to ensure patient safety and product integrity. According to <strong data-start=\"1554\" data-end=\"1571\"><a href=\"https:\/\/www.packqc.com\/nn\/product-category\/iso\/iso-9626\/\" target=\"_blank\" rel=\"noopener\">ISO 9626<\/a>:2016<\/strong>, stainless steel needle tubing used in medical devices must undergo rigorous testing to confirm its durability under stress.<\/p>\n\n\n\n<p>This standard, particularly <em data-start=\"1728\" data-end=\"1737\">Annex C<\/em>, outlines a detailed method to evaluate the <em data-start=\"1782\" data-end=\"1816\">resistance of tubing to breakage<\/em>. By following these requirements, manufacturers not only ensure compliance but also improve the market trustworthiness of their products.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Resistance of Tubing to Breakage \u2013 ISO 9626 Annex C Test Method<\/h2>\n\n\n\n<p>The bending test defined in <strong data-start=\"2060\" data-end=\"2080\"><a href=\"https:\/\/www.packqc.com\/nn\/standard\/iso-9626\/\" target=\"_blank\" data-type=\"standard\" data-id=\"9825\" rel=\"noreferrer noopener\">ISO 9626<\/a> Annex C<\/strong> involves fixing one end of the tubing and applying a controlled force at a specific distance to bend the tubing in both directions through a defined angle. This test simulates the stresses the needle would encounter during actual clinical use.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"2328\" data-end=\"2346\">Bending Angles<\/strong>:\n<ul class=\"wp-block-list\">\n<li><em style=\"font-size: 16px;\" data-start=\"2354\" data-end=\"2364\">(25 \u00b11)\u00b0<\/em> for regular-walled tubing<\/li>\n\n\n\n<li><em style=\"font-size: 16px;\" data-start=\"2397\" data-end=\"2407\">(20 \u00b11)\u00b0<\/em> for thin-walled tubing<\/li>\n\n\n\n<li><em style=\"font-size: 16px;\" data-start=\"2437\" data-end=\"2447\">(15 \u00b11)\u00b0<\/em> for extra-thin and ultra-thin-walled tubing<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"2497\" data-end=\"2512\">Test Cycles<\/strong>:<br>20 complete cycles of forward and reverse bending<\/li>\n\n\n\n<li><strong data-start=\"2572\" data-end=\"2590\">Test Frequency<\/strong>:<br>0.5 Hz<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\" style=\"margin-top:0;margin-bottom:0\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"Needle Tough Test with interval in the middle| Left and Right Bending\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/adX7tiXymqw?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<\/div><\/figure>\n\n\n\n<p>After testing, the needle is visually inspected for signs of breakage. This procedure offers a standardized method to evaluate tubing toughness, aiding in quality assurance and regulatory compliance.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Introducing the NTT-01 Needle Toughness Tester<\/h2>\n\n\n\n<p>The <strong data-start=\"2870\" data-end=\"2904\">NTT-01 <a href=\"https:\/\/www.packqc.com\/nn\/product\/needle-toughness-tester\/\">Needle Toughness Tester<\/a><\/strong> is designed to perform the ISO 9626 Annex C test method with high precision and user-friendly controls. It enables manufacturers to assess the <em data-start=\"3048\" data-end=\"3079\">needle resistance to breakage<\/em> across various tubing wall thicknesses with consistency and accuracy.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong data-start=\"3151\" data-end=\"3172\">Working Mechanism<\/strong><\/h3>\n\n\n\n<p>The device rigidly fixes one end of the tubing while applying force at a designated point to bend the tubing to the required angle. The system then reverses the direction and repeats the process, automatically managing test frequency and angle limits.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Key Features of the Needle Toughness Tester<\/h2>\n\n\n\n<p>This instrument is ideal for research labs, production lines, and quality control departments.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"3584\" data-end=\"3623\">PLC-Controlled with HMI Touchscreen<\/strong>: Enables intuitive operation and configuration.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3676\" data-end=\"3713\">Two-Way and One-Way Bending Modes<\/strong>: Supports both test requirements.<\/li>\n\n\n\n<li><strong style=\"font-style: inherit;\" data-start=\"3752\" data-end=\"3782\">Adjustable Test Parameters<\/strong>: Including frequency, dwell time, and bending angle.<\/li>\n\n\n\n<li><strong style=\"font-style: inherit;\" data-start=\"3840\" data-end=\"3869\">Automatic Return Function<\/strong>: Ensures test integrity even in power failure situations.<\/li>\n\n\n\n<li><strong style=\"font-style: inherit;\" data-start=\"3932\" data-end=\"3959\">Integrated Microprinter<\/strong>: For immediate test result documentation.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Main Technical Parameters<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Parameter<\/th><th>Specification<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">Bending Mode<\/td><td class=\"has-text-align-center\" data-align=\"center\">Two-way, one-way<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Bending Angle<\/td><td class=\"has-text-align-center\" data-align=\"center\">15\u00b0, 20\u00b0, 25\u00b0<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Test Frequency<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.5 Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Power Supply<\/td><td class=\"has-text-align-center\" data-align=\"center\">110~220V<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Standard Configuration<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Needle Toughness Tester<\/li>\n\n\n\n<li>Precision Caliper<\/li>\n\n\n\n<li>Power Cord<\/li>\n\n\n\n<li>Fuse<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">Applications in Medical and Related Industries<\/h2>\n\n\n\n<p>The NTT-01 is primarily used in testing hypodermic needles, catheters, and tubing in <strong data-start=\"4656\" data-end=\"4683\">medical, pharmaceutical<\/strong>, and <strong data-start=\"4689\" data-end=\"4714\">syringe manufacturing<\/strong> sectors. It is also widely applicable to <strong data-start=\"4756\" data-end=\"4787\">quality inspection agencies<\/strong>, ensuring end products comply with international safety standards like <a href=\"https:\/\/www.iso.org\/standard\/60480.html\" target=\"_blank\" rel=\"noopener nofollow\"><em data-start=\"4859\" data-end=\"4869\">ISO 9626<\/em><\/a>.<\/p>\n\n\n\n<p>For companies looking to <strong data-start=\"4899\" data-end=\"4931\">customize testing procedures<\/strong> or automate part of their quality assurance process, Cell Instruments offers tailored solutions designed to streamline operations without compromising accuracy.<\/p>\n\n\n\n<p>Maintaining <em data-start=\"5129\" data-end=\"5160\">needle resistance to breakage<\/em> isn&#8217;t just a regulatory necessity\u2014it\u2019s a matter of product integrity and user safety. With the <strong data-start=\"5256\" data-end=\"5290\">NTT-01 Needle Toughness Tester<\/strong>, Cell Instruments delivers an advanced, compliant solution for manufacturers striving for excellence. Whether you\u2019re testing standard medical tubing or custom-designed components, the NTT-01 ensures consistent performance and peace of mind.<\/p>\n\n\n\n<p>To learn more about how the NTT-01 can improve your testing standards or to discuss <strong data-start=\"5617\" data-end=\"5646\">automation transformation<\/strong> services, contact <strong data-start=\"5665\" data-end=\"5695\"><a href=\"https:\/\/www.packqc.com\/nn\/\" target=\"_blank\" rel=\"noopener\">Cell Instruments<\/a> Co., Ltd.<\/strong> today.<\/p>","protected":false},"excerpt":{"rendered":"<p>Ensuring needle resistance to breakage is a critical part of medical device safety and reliability, particularly for hypodermic needles.<\/p>","protected":false},"featured_media":5285,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"product-category":[456,579,434,580,438,581,593],"product-tag":[],"class_list":["post-9582","products","type-products","status-publish","has-post-thumbnail","hentry","product-category-gb","product-category-gb-t-18457","product-category-iso","product-category-iso-9626","product-category-medical-and-pharmaceutical-testing","product-category-needle-toughness-tester","product-category-syringe-testing"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/products\/9582","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/types\/products"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/media\/5285"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/media?parent=9582"}],"wp:term":[{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/product-category?post=9582"},{"taxonomy":"product-tag","embeddable":true,"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/product-tag?post=9582"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}