{"id":9585,"date":"2026-02-02T14:53:24","date_gmt":"2026-02-02T06:53:24","guid":{"rendered":"https:\/\/www.packqc.com\/products\/break-loose-force-and-glide-force-tester\/"},"modified":"2026-04-16T15:26:12","modified_gmt":"2026-04-16T07:26:12","slug":"break-loose-force-and-glide-force-tester","status":"publish","type":"products","link":"https:\/\/www.packqc.com\/nn\/products\/break-loose-force-and-glide-force-tester\/","title":{"rendered":"SSR-01 Syringe Sliding Resistance Tester"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Break Loose and Glide Force Testing<\/h2>\n\n\n\n<p>In syringe performance evaluation, <strong data-start=\"496\" data-end=\"535\">break loose and glide force testing<\/strong> plays a crucial role in assessing the smoothness and reliability of the plunger movement. This test determines the force required to initiate and maintain the motion of the syringe piston, ensuring consistent drug delivery and patient safety.<\/p>\n\n\n\n<p>Cell Instruments, a leading manufacturer of <strong data-start=\"826\" data-end=\"857\">materials testing equipment<\/strong>, provides advanced <strong data-start=\"877\" data-end=\"925\">break loose and glide force testing machines<\/strong> designed according to <em data-start=\"948\" data-end=\"960\">ISO 7886-1<\/em> standards. These instruments help manufacturers, laboratories, and quality control professionals ensure that their syringes meet international quality and performance requirements.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">ISO 7886-1 and Syringe Performance<\/h2>\n\n\n\n<p>The international standard <strong data-start=\"1233\" data-end=\"1247\">ISO 7886-1<\/strong> specifies the requirements and test methods for sterile hypodermic syringes for single use. Annex E of the standard outlines the <strong data-start=\"1377\" data-end=\"1450\">test method for determining the forces required to operate the piston<\/strong>, including both <em data-start=\"1467\" data-end=\"1486\">break loose force<\/em> and <em data-start=\"1491\" data-end=\"1506\">gliding force<\/em>.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"1513\" data-end=\"1534\">Break loose force<\/strong> refers to the <em data-start=\"1549\" data-end=\"1564\">initial force<\/em> required to start the plunger movement.<\/li>\n\n\n\n<li><strong data-start=\"1609\" data-end=\"1626\">Gliding force<\/strong> represents the <em data-start=\"1642\" data-end=\"1660\">continuous force<\/em> needed to maintain piston movement throughout the stroke.<\/li>\n<\/ul>\n\n\n\n<p>These two parameters are critical indicators of syringe quality, influencing user comfort, injection accuracy, and drug flow stability. Excessive or inconsistent forces can result in jerky movement, dosage errors, or even syringe failure.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Principle of Break Loose and Glide Force Testing<br><small> \u2014\u2014 ISO 7886-1 Annex E<\/small><\/h2>\n\n\n\n<p>The <strong data-start=\"2029\" data-end=\"2068\">break loose and glide force testing<\/strong> process uses a <strong data-start=\"2084\" data-end=\"2114\">mechanical testing machine<\/strong> to push the syringe plunger while measuring and recording the applied force. The test evaluates how smoothly the plunger operates under standardized conditions, such as temperature and displacement speed.<\/p>\n\n\n\n<p>During the test:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>The syringe is filled with water maintained at <em data-start=\"2392\" data-end=\"2404\">(23 \u00b1 5)\u00b0C<\/em>.<\/li>\n\n\n\n<li>The syringe nozzle connects to a water reservoir at a controlled level.<\/li>\n\n\n\n<li>The testing machine moves the plunger at a constant rate of <em data-start=\"2548\" data-end=\"2568\">(100 \u00b1 5) mm\/min).<\/em><\/li>\n\n\n\n<li>The system records:\n<ul class=\"wp-block-list\">\n<li>The <strong data-start=\"2605\" data-end=\"2631\">break loose force (Fs)<\/strong> \u2013 force required to start piston movement.<\/li>\n\n\n\n<li>The <strong data-start=\"2686\" data-end=\"2712\">mean gliding force (F)<\/strong> \u2013 average force during steady plunger movement.<\/li>\n\n\n\n<li>The <strong data-start=\"2772\" data-end=\"2796\">maximum force (Fmax)<\/strong> \u2013 peak force observed during movement.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<p>These parameters are plotted as a <em style=\"font-size: 16px;\" data-start=\"2873\" data-end=\"2899\">force-displacement curve<\/em>, providing clear visualization of syringe performance characteristics.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">SSR-01 Syringe Sliding Resistance Tester<\/h2>\n\n\n\n<p>Cell Instruments offers precision-engineered <strong data-start=\"3081\" data-end=\"3129\">break loose and glide force testing machines<\/strong> that comply with <em data-start=\"3147\" data-end=\"3159\">ISO 7886-1<\/em> and related pharmaceutical testing standards.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Key Features Include:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"3598\" data-end=\"3616\">High Precision<\/strong>: Force accuracy up to <strong data-start=\"3639\" data-end=\"3647\">0.5%<\/strong> of full-scale reading.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3673\" data-end=\"3698\">Wide Test Speed Range<\/strong>: Adjustable from <strong style=\"font-size: 16px;\" data-start=\"3716\" data-end=\"3735\">1 to 500 mm\/min<\/strong> to accommodate various test conditions.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3778\" data-end=\"3805\">Three-Force Measurement<\/strong>: Automatically captures break loose force, mean glide force, and maximum force.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3888\" data-end=\"3915\">User-Friendly Interface<\/strong>: <strong style=\"font-size: 16px;\" data-start=\"3917\" data-end=\"3935\">PLC-controlled<\/strong> with a <strong style=\"font-size: 16px;\" data-start=\"3943\" data-end=\"3969\">7-inch HMI touchscreen<\/strong> for seamless operation.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3996\" data-end=\"4016\">Built-in Printer<\/strong>: Provides immediate test results for documentation and quality assurance.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"4093\" data-end=\"4116\">Overload Protection<\/strong>: Ensures long-term durability and operator safety.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Main Parameter<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Load Cell<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">200N (or as required)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Test Speed<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">1~500mm\/min<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Accuracy<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">0.01mm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Power<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">110~220V<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Applications and Industry Impact<\/h2>\n\n\n\n<p>Break loose force and glide force testing is critical across multiple sectors:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"4294\" data-end=\"4313\">Medical Devices<\/strong>: Ensures syringe safety and usability for healthcare professionals and patients.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"4397\" data-end=\"4416\">Pharmaceuticals<\/strong>: Verifies product consistency before distribution.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"4470\" data-end=\"4492\">Regulatory Testing<\/strong>: Provides data necessary for compliance with <strong style=\"font-size: 16px;\" data-start=\"4538\" data-end=\"4560\"><a href=\"https:\/\/www.iso.org\/standard\/64790.html\" target=\"_blank\" rel=\"noopener nofollow\">ISO 7886-1<\/a> testing<\/strong> requirements.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"4577\" data-end=\"4596\">Quality Control<\/strong>: Helps manufacturers maintain high production standards and reduce defect rates.<\/li>\n<\/ul>\n\n\n\n<p>Thanks to its precision and adherence to ISO protocols, the SSR-01 is ideal for <strong data-start=\"4759\" data-end=\"4810\">syringe manufacturers, pharmaceutical companies<\/strong>, and <strong data-start=\"4816\" data-end=\"4847\">quality inspection agencies<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Why Choose Cell Instruments?<\/h2>\n\n\n\n<p>As an experienced manufacturer specializing in <strong data-start=\"4456\" data-end=\"4491\">material testing and automation<\/strong>, Cell Instruments provides complete solutions for <strong data-start=\"4542\" data-end=\"4589\">syringe break loose and glide force testing<\/strong>. We combine high-precision engineering, customizable software, and expert technical support to help clients meet stringent industry standards.<\/p>\n\n\n\n<p><strong data-start=\"4962\" data-end=\"5001\">Break loose and glide force testing<\/strong> is an essential part of syringe quality verification according to <em data-start=\"5068\" data-end=\"5080\">ISO 7886-1<\/em>. It directly affects usability, safety, and regulatory compliance. By using professional testing instruments from <strong data-start=\"5195\" data-end=\"5215\">Cell Instruments<\/strong>, laboratories and manufacturers can achieve reliable, accurate, and reproducible results\u2014enhancing both product performance and customer confidence.<\/p>","protected":false},"excerpt":{"rendered":"<p>Break loose and glide force testing measure the force required to initiate and maintain the motion of the syringe piston.<\/p>","protected":false},"featured_media":5356,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"product-category":[454,438,495,593],"product-tag":[],"class_list":["post-9585","products","type-products","status-publish","has-post-thumbnail","hentry","product-category-custom-lab-testing-instruments-manufacturer","product-category-medical-and-pharmaceutical-testing","product-category-pharmaceutical-testing","product-category-syringe-testing"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/products\/9585","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/types\/products"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/media\/5356"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/media?parent=9585"}],"wp:term":[{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/product-category?post=9585"},{"taxonomy":"product-tag","embeddable":true,"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/product-tag?post=9585"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}