{"id":9586,"date":"2026-02-02T14:53:24","date_gmt":"2026-02-02T06:53:24","guid":{"rendered":"https:\/\/www.packqc.com\/products\/syringe-tube-stiffness-tester\/"},"modified":"2026-04-16T15:32:27","modified_gmt":"2026-04-16T07:32:27","slug":"syringe-tube-stiffness-tester","status":"publish","type":"products","link":"https:\/\/www.packqc.com\/nn\/products\/syringe-tube-stiffness-tester\/","title":{"rendered":"TS-01 Tube Stiffness Tester"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Introduction to Syringe Tube Stiffness Tester<\/h2>\n\n\n\n<p>For professionals in medical device manufacturing, <strong data-start=\"577\" data-end=\"603\">syringe tube stiffness<\/strong> plays a critical role in ensuring the reliability, safety, and usability of hypodermic needles. The <strong data-start=\"704\" data-end=\"737\">Syringe Tube Stiffness Tester<\/strong>, specifically designed to evaluate the stiffness of stainless steel needle tubing, provides a reliable method for quality control and standard compliance. This instrument, such as Cell Instruments\u2019 <strong data-start=\"936\" data-end=\"945\">TS-01<\/strong>, is indispensable for meeting the requirements outlined in <a href=\"https:\/\/www.packqc.com\/nn\/standard\/iso-9626\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"1005\" data-end=\"1017\">ISO 9626<\/strong><\/a>.<\/p>\n\n\n\n<p>Stiffness is directly linked to mechanical integrity. Tubing that lacks appropriate stiffness may bend, break, or deform during use\u2014posing risks of injury, inaccurate dosing, or contamination. Conversely, overly rigid tubing may fail to provide adequate flexibility, leading to fracture or discomfort. The <strong data-start=\"1326\" data-end=\"1359\">Syringe Tube Stiffness Tester<\/strong> addresses these challenges by delivering precise, repeatable measurements that conform to global standards.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">ISO 9626 and Syringe Tube Stiffness Testing Standards<\/h2>\n\n\n\n<p><strong data-start=\"1534\" data-end=\"1546\">ISO 9626<\/strong>, specifically <strong data-start=\"1561\" data-end=\"1572\">Annex B<\/strong>, defines the <strong data-start=\"1586\" data-end=\"1610\">standard test method<\/strong> for measuring the stiffness of stainless steel needle tubing. This long tail keyword\u2014<strong data-start=\"1696\" data-end=\"1716\">ISO 9626 testing<\/strong>\u2014is essential for manufacturers who must demonstrate compliance with international medical device regulations.<\/p>\n\n\n\n<p>According to ISO 9626 Annex B:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The tubing is supported at both ends while a force\u2014up to 60 N\u2014is applied to its midpoint using a wedge-shaped plunger.<\/li>\n\n\n\n<li>The resulting deflection is measured with a precision of 0.01 mm.<\/li>\n\n\n\n<li>The test ensures that the tubing\u2019s stiffness is within acceptable limits for the intended medical application.<\/li>\n<\/ul>\n\n\n\n<p>The <strong data-start=\"2167\" data-end=\"2200\">Syringe Tube Stiffness Tester<\/strong> from Cell Instruments is engineered to fulfill each of these requirements, making it ideal for quality assurance teams and regulatory bodies.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Working Mechanism and Structure of TS-01 Syringe Tube Stiffness Tester<\/h2>\n\n\n\n<p>The <strong data-start=\"2430\" data-end=\"2469\">TS-01 Syringe Tube Stiffness Tester<\/strong> employs a robust and accurate system designed to minimize measurement errors. It uses:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>A <strong data-start=\"2562\" data-end=\"2586\">wedge-shaped plunger<\/strong> with a 1 mm radius, inclined at 60\u00b0, as specified in ISO 9626 Annex B.<\/li>\n\n\n\n<li>A <strong data-start=\"2662\" data-end=\"2685\">precision load cell<\/strong> and movable crosshead to ensure accurate force application.<\/li>\n\n\n\n<li>A <strong data-start=\"2750\" data-end=\"2764\">tubing pan<\/strong> that centers the test sample directly beneath the plunger.<\/li>\n<\/ul>\n\n\n\n<p>This configuration mimics the ISO-specified test conditions, ensuring reproducibility and data integrity.<\/p>\n\n\n\n<p><strong data-start=\"2934\" data-end=\"2956\">System Highlights:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"2961\" data-end=\"2976\">PLC control<\/strong> and <strong data-start=\"2981\" data-end=\"3008\">7-inch HMI touch screen<\/strong> interface<\/li>\n\n\n\n<li><strong data-start=\"3023\" data-end=\"3053\">Precision ball screw drive<\/strong> for consistent speed control<\/li>\n\n\n\n<li><strong data-start=\"3087\" data-end=\"3105\">Variable speed<\/strong> from 1 to 500 mm\/min for customized testing<\/li>\n\n\n\n<li><strong data-start=\"3154\" data-end=\"3206\">High-resolution deflection measurement (0.01 mm)<\/strong><\/li>\n\n\n\n<li><strong data-start=\"3211\" data-end=\"3234\">Overload protection<\/strong> for equipment and sample safety<\/li>\n\n\n\n<li><strong data-start=\"3271\" data-end=\"3300\">Automatic return function<\/strong> post-test<\/li>\n\n\n\n<li><strong data-start=\"3315\" data-end=\"3342\">Integrated microprinter<\/strong> for immediate result documentation<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Test Principle and Methodology Explained<\/h2>\n\n\n\n<p>The principle of the stiffness test is straightforward but scientifically grounded:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong data-start=\"3519\" data-end=\"3534\">Positioning<\/strong>: The syringe tubing is supported at both ends at a span length specified in ISO 9626 Table 2.<\/li>\n\n\n\n<li><strong data-start=\"3632\" data-end=\"3653\">Force Application<\/strong>: The plunger applies a downward force at the midpoint, with control over speed (1\u201310 mm\/min for ISO 9626; up to 500 mm\/min for customizable tests).<\/li>\n\n\n\n<li><strong data-start=\"3805\" data-end=\"3831\">Deflection Measurement<\/strong>: The instrument measures the tubing&#8217;s deflection with \u00b10.01 mm accuracy.<\/li>\n\n\n\n<li><strong data-start=\"3908\" data-end=\"3926\">Data Recording<\/strong>: Information such as tubing size, material, deflection, test speed, and force applied are recorded and printed.<\/li>\n<\/ol>\n\n\n\n<p>This test ensures compliance with both ISO and internal quality benchmarks.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Why Choose Cell Instruments\u2019 TS-01 Syringe Tube Stiffness Tester?<\/h2>\n\n\n\n<p>Cell Instruments has built a reputation for precision, compliance, and customizability. The <strong data-start=\"4286\" data-end=\"4325\">TS-01 Syringe Tube Stiffness Tester<\/strong> offers exceptional accuracy and robust features tailored for syringe manufacturing and quality labs. Our team also supports <strong data-start=\"4450\" data-end=\"4482\">customized test requirements<\/strong> and <strong data-start=\"4487\" data-end=\"4511\">automation solutions<\/strong>, ensuring integration with existing workflows in packaging, pharmaceuticals, and medical device production.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Applications and Industries Served<\/h2>\n\n\n\n<p>The <strong data-start=\"4671\" data-end=\"4704\">Syringe Tube Stiffness Tester<\/strong> is widely used across multiple sectors:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"4749\" data-end=\"4781\">Medical device manufacturing<\/strong><\/li>\n\n\n\n<li><strong data-start=\"4786\" data-end=\"4815\">Pharmaceutical production<\/strong><\/li>\n\n\n\n<li><strong data-start=\"4820\" data-end=\"4844\">Healthcare packaging<\/strong><\/li>\n\n\n\n<li><strong data-start=\"4849\" data-end=\"4891\">Regulatory compliance and testing labs<\/strong><\/li>\n\n\n\n<li><strong data-start=\"4896\" data-end=\"4942\">Quality assurance for needle manufacturers<\/strong><\/li>\n<\/ul>\n\n\n\n<p>Whether you\u2019re validating product safety, meeting <strong data-start=\"4994\" data-end=\"5014\"><a href=\"https:\/\/www.iso.org\/standard\/60480.html\" target=\"_blank\" rel=\"noopener nofollow\">ISO 9626<\/a> testing<\/strong> criteria, or ensuring mechanical reliability, the TS-01 is your go-to solution.<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Syringe Tube Stiffness Tester measure the stiffness of stainless steel needle tubing, provides a reliable method for quality control and standard compliance.<\/p>","protected":false},"featured_media":5367,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"product-category":[434,580,438,593,582],"product-tag":[],"class_list":["post-9586","products","type-products","status-publish","has-post-thumbnail","hentry","product-category-iso","product-category-iso-9626","product-category-medical-and-pharmaceutical-testing","product-category-syringe-testing","product-category-tube-stiffness-tester"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/products\/9586","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/types\/products"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/media\/5367"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/media?parent=9586"}],"wp:term":[{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/product-category?post=9586"},{"taxonomy":"product-tag","embeddable":true,"href":"https:\/\/www.packqc.com\/nn\/wp-json\/wp\/v2\/product-tag?post=9586"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}