{"id":6992,"date":"2025-07-22T15:11:56","date_gmt":"2025-07-22T07:11:56","guid":{"rendered":"https:\/\/www.packqc.com\/?p=6992"},"modified":"2025-09-12T08:34:06","modified_gmt":"2025-09-12T00:34:06","slug":"iso-9187-1","status":"publish","type":"post","link":"https:\/\/www.packqc.com\/pl\/iso-9187-1\/","title":{"rendered":"Zgodno\u015b\u0107 z norm\u0105 ISO 9187 i pomiar si\u0142y \u0142ami\u0105cej dla szklanych ampu\u0142ek"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6992\" class=\"elementor elementor-6992\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9ef650f e-flex e-con-boxed e-con e-parent\" data-id=\"9ef650f\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2b878ea elementor-widget elementor-widget-theme-post-title elementor-page-title elementor-widget-heading\" data-id=\"2b878ea\" data-element_type=\"widget\" data-widget_type=\"theme-post-title.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Zgodno\u015b\u0107 z norm\u0105 ISO 9187 i pomiar si\u0142y \u0142ami\u0105cej dla szklanych ampu\u0142ek<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9e32292 elementor-widget elementor-widget-heading\" data-id=\"9e32292\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Wprowadzenie do normy ISO 9187-1 dla ampu\u0142ek<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-31d2386 e-flex e-con-boxed e-con e-parent\" data-id=\"31d2386\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a1a4f81 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"a1a4f81\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"492\" data-end=\"1014\">ISO 9187 to kluczowy mi\u0119dzynarodowy standard, kt\u00f3ry okre\u015bla wymagania techniczne i wydajno\u015bciowe dla szklanych ampu\u0142ek stosowanych w medycznych produktach iniekcyjnych. Norma zapewnia, \u017ce ampu\u0142ki s\u0105 bezpieczne, niezawodne i odpowiednie do przechowywania sterylnych produkt\u00f3w farmaceutycznych. Dotyczy ona przede wszystkim ampu\u0142ek wykonanych ze szk\u0142a i koncentruje si\u0119 na kluczowych w\u0142a\u015bciwo\u015bciach, takich jak <strong data-start=\"889\" data-end=\"914\">odporno\u015b\u0107 hydrolityczna<\/strong>, <strong data-start=\"916\" data-end=\"937\">jako\u015b\u0107 wy\u017carzania<\/strong>i <strong data-start=\"947\" data-end=\"965\">si\u0142a zrywaj\u0105ca<\/strong> wymagane do czystego i bezpiecznego otwarcia ampu\u0142ki.<\/p><p data-start=\"1016\" data-end=\"1314\">W \u015brodowisku medycznym i farmaceutycznym ampu\u0142ki musz\u0105 zachowywa\u0107 sterylno\u015b\u0107, a jednocze\u015bnie by\u0107 \u0142atwe do otwarcia bez powodowania od\u0142amk\u00f3w szk\u0142a lub obra\u017ce\u0144 u\u017cytkownika. W zwi\u0105zku z tym, dok\u0142adne <strong data-start=\"1175\" data-end=\"1224\">Pomiar si\u0142y \u0142ami\u0105cej dla szklanych ampu\u0142ek<\/strong> jest niezb\u0119dna, a <a href=\"https:\/\/www.iso.org\/standard\/55920.html\" target=\"_blank\" rel=\"noopener nofollow\">Norma ISO 9187-1<\/a> zapewnia precyzyjne protoko\u0142y testowe do oceny tej w\u0142a\u015bciwo\u015bci.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8349dad elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"8349dad\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.packqc.com\/pl\/product\/bst-01-glass-ampoule-break-force-tester\/\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1011\" height=\"662\" src=\"https:\/\/www.packqc.com\/wp-content\/uploads\/2025\/07\/ampoule-breaking-tester.webp\" class=\"attachment-large size-large wp-image-7003\" alt=\"iso 9187-1\" srcset=\"https:\/\/www.packqc.com\/wp-content\/uploads\/2025\/07\/ampoule-breaking-tester.webp 1011w, https:\/\/www.packqc.com\/wp-content\/uploads\/2025\/07\/ampoule-breaking-tester-600x393.webp 600w, https:\/\/www.packqc.com\/wp-content\/uploads\/2025\/07\/ampoule-breaking-tester-300x196.webp 300w, https:\/\/www.packqc.com\/wp-content\/uploads\/2025\/07\/ampoule-breaking-tester-768x503.webp 768w, https:\/\/www.packqc.com\/wp-content\/uploads\/2025\/07\/ampoule-breaking-tester-18x12.webp 18w\" sizes=\"(max-width: 1011px) 100vw, 1011px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3ffff35 e-flex e-con-boxed e-con e-parent\" data-id=\"3ffff35\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6cb9a7e elementor-widget elementor-widget-heading\" data-id=\"6cb9a7e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pomiar si\u0142y \u0142ami\u0105cej dla szklanych ampu\u0142ek i rola normy ISO 9187-1<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5809b79 e-flex e-con-boxed e-con e-parent\" data-id=\"5809b79\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4a1c345 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"4a1c345\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1401\" data-end=\"1641\">Ten <strong data-start=\"1405\" data-end=\"1441\">Test z\u0142amania ampu\u0142ki ISO 9187-1<\/strong> definiuje znormalizowan\u0105 metod\u0119 okre\u015blania si\u0142y zrywaj\u0105cej ampu\u0142ki. Gwarantuje to, \u017ce p\u0119kn\u0105 one w przewidywalny spos\u00f3b w okre\u015blonym punkcie, zwykle oznaczonym ceramicznym pier\u015bcieniem lub kolorowym pigmentem.<\/p><p data-start=\"1643\" data-end=\"1815\">Wed\u0142ug <strong data-start=\"1656\" data-end=\"1675\">ISO 9187-1:2010<\/strong>Test si\u0142y zrywaj\u0105cej musi by\u0107 przeprowadzony przy u\u017cyciu maszyny do pr\u00f3b rozci\u0105gania zgodnej z norm\u0105 ISO 7500-1. Kluczowe specyfikacje aparatury obejmuj\u0105:<\/p><ul><li data-start=\"1819\" data-end=\"1846\"><strong data-start=\"1819\" data-end=\"1833\">Pr\u0119dko\u015b\u0107 testowa<\/strong>: 10 mm\/min<\/li><li data-start=\"1849\" data-end=\"1883\"><strong data-start=\"1849\" data-end=\"1874\">Zakres pomiaru si\u0142y<\/strong>: 200 N<\/li><li data-start=\"1886\" data-end=\"1922\"><strong data-start=\"1886\" data-end=\"1909\">Przyk\u0142adowe kondycjonowanie<\/strong>: 20 \u00b1 5 \u00b0C<\/li><li data-start=\"1925\" data-end=\"1977\"><strong data-start=\"1925\" data-end=\"1942\">Plan pobierania pr\u00f3bek<\/strong>: Losowy, zgodnie z ISO 2859-1, poziom S-4<\/li><\/ul><p data-start=\"1979\" data-end=\"2298\">Ampu\u0142ka jest umieszczana z si\u0142\u0105 przy\u0142o\u017con\u0105 prostopadle do punktu p\u0119kni\u0119cia. Czyste p\u0119kni\u0119cie z si\u0142\u0105 mieszcz\u0105c\u0105 si\u0119 w okre\u015blonych granicach (zgodnie z tabel\u0105 2 normy) jest wymagane dla zgodno\u015bci. Odchylenia k\u0105ta lub pozycji mog\u0105 drastycznie zwi\u0119kszy\u0107 si\u0142\u0119 \u0142ami\u0105c\u0105, wskazuj\u0105c na niew\u0142a\u015bciwy projekt lub produkcj\u0119 ampu\u0142ki.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f2ca4ec elementor-widget__width-initial elementor-widget elementor-widget-video\" data-id=\"f2ca4ec\" data-element_type=\"widget\" data-settings=\"{&quot;youtube_url&quot;:&quot;https:\\\/\\\/youtu.be\\\/fL78KBZwj3g?si=KFNn9WLEJvHr9UsM&quot;,&quot;autoplay&quot;:&quot;yes&quot;,&quot;play_on_mobile&quot;:&quot;yes&quot;,&quot;mute&quot;:&quot;yes&quot;,&quot;loop&quot;:&quot;yes&quot;,&quot;video_type&quot;:&quot;youtube&quot;,&quot;controls&quot;:&quot;yes&quot;}\" data-widget_type=\"video.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-wrapper elementor-open-inline\">\n\t\t\t<div class=\"elementor-video\"><\/div>\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6dd566f e-flex e-con-boxed e-con e-parent\" data-id=\"6dd566f\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6c111e9 elementor-widget elementor-widget-heading\" data-id=\"6c111e9\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Podstawowe wymagania testowe zgodnie z norm\u0105 ISO 9187-1<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-72030ce e-flex e-con-boxed e-con e-parent\" data-id=\"72030ce\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0ad38e2 elementor-widget elementor-widget-text-editor\" data-id=\"0ad38e2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2353\" data-end=\"2461\">Aby zapewni\u0107, \u017ce ampu\u0142ki s\u0105 zar\u00f3wno bezpieczne dla u\u017cytkownika, jak i zgodne z wymogami produkcyjnymi, norma ISO 9187-1 okre\u015bla nast\u0119puj\u0105ce standardy:<\/p><ol><li data-start=\"2466\" data-end=\"2622\"><strong data-start=\"2466\" data-end=\"2491\">Odporno\u015b\u0107 hydrolityczna<\/strong><br data-start=\"2491\" data-end=\"2494\" \/>Musi by\u0107 zgodny z <strong data-start=\"2513\" data-end=\"2527\">ISO 4802-1<\/strong> I <strong data-start=\"2532\" data-end=\"2546\">ISO 4802-2<\/strong>zapewniaj\u0105c, \u017ce szk\u0142o nie ulegnie zniszczeniu pod wp\u0142ywem wody lub sterylizacji.<\/li><li data-start=\"2627\" data-end=\"2810\"><strong data-start=\"2627\" data-end=\"2648\">Jako\u015b\u0107 wy\u017carzania<\/strong><br data-start=\"2648\" data-end=\"2651\" \/>Napr\u0119\u017cenie szcz\u0105tkowe po wy\u017carzaniu nie mo\u017ce przekracza\u0107 <strong data-start=\"2702\" data-end=\"2726\">50 nm na milimetr<\/strong> grubo\u015bci szk\u0142a. Nieprawid\u0142owe wy\u017carzanie mo\u017ce prowadzi\u0107 do mikrop\u0119kni\u0119\u0107 lub nag\u0142ego p\u0119kni\u0119cia.<\/li><li data-start=\"2815\" data-end=\"2989\"><strong data-start=\"2815\" data-end=\"2833\">Breaking Force<\/strong><br data-start=\"2833\" data-end=\"2836\" \/>Mierzone w kontrolowanych warunkach mechanicznych. P\u0119kni\u0119cie powinno nast\u0105pi\u0107 czysto w zaprojektowanym punkcie, z minimaln\u0105 ilo\u015bci\u0105 pozosta\u0142o\u015bci i bez fragmentacji szk\u0142a.<\/li><li data-start=\"2994\" data-end=\"3214\"><strong data-start=\"2994\" data-end=\"3055\">Po\u0142o\u017cenie i stabilno\u015b\u0107 punktu przerwania (zgodnie z ISO 9187-2)<\/strong><br data-start=\"3055\" data-end=\"3058\" \/>Punkt przerwania musi by\u0107 ustawiony centralnie (odchylenie \u00b11 mm) i wytrzymywa\u0107 sterylizacj\u0119, czyszczenie i szok termiczny bez przemieszczania si\u0119 lub degradacji.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c9ae016 e-flex e-con-boxed e-con e-parent\" data-id=\"c9ae016\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0fe0339 elementor-widget elementor-widget-heading\" data-id=\"0fe0339\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Dlaczego dok\u0142adny test si\u0142y zrywaj\u0105cej ma znaczenie?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-bef302f e-flex e-con-boxed e-con e-parent\" data-id=\"bef302f\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-885df47 elementor-widget elementor-widget-text-editor\" data-id=\"885df47\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3272\" data-end=\"3463\">Dok\u0142adny <strong data-start=\"3281\" data-end=\"3330\">Pomiar si\u0142y \u0142ami\u0105cej dla szklanych ampu\u0142ek<\/strong> ma kluczowe znaczenie dla zachowania bezpiecze\u0144stwa pacjent\u00f3w, integralno\u015bci produktu i zgodno\u015bci z przepisami. Nieprzewidywalne p\u0119kni\u0119cie ampu\u0142ki mo\u017ce prowadzi\u0107 do:<\/p><ul><li data-start=\"3467\" data-end=\"3508\">Zanieczyszczenie produktu do wstrzykiwa\u0144<\/li><li data-start=\"3511\" data-end=\"3547\">Obra\u017cenia pracownik\u00f3w s\u0142u\u017cby zdrowia<\/li><li data-start=\"3550\" data-end=\"3590\">Odrzucanie ca\u0142ych partii produkcyjnych<\/li><li data-start=\"3593\" data-end=\"3641\">Niezgodno\u015b\u0107 z mi\u0119dzynarodowymi audytami jako\u015bci<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4c71e50 e-flex e-con-boxed e-con e-parent\" data-id=\"4c71e50\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b91c9d2 elementor-widget elementor-widget-heading\" data-id=\"b91c9d2\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Zalecane rozwi\u0105zanie: BST-01 Ampoule Breaking Tester firmy Cell Instruments<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b2a4e64 e-flex e-con-boxed e-con e-parent\" data-id=\"b2a4e64\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f62dde6 elementor-widget elementor-widget-text-editor\" data-id=\"f62dde6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3728\" data-end=\"3988\">Dla producent\u00f3w farmaceutyk\u00f3w, laboratori\u00f3w kontroli jako\u015bci i organ\u00f3w kontroli regulacyjnej poszukuj\u0105cych niezawodnej zgodno\u015bci z <strong data-start=\"3850\" data-end=\"3862\">Norma ISO 9187<\/strong>w <strong data-start=\"3868\" data-end=\"3902\">Tester przebicia ampu\u0142ki BST-01<\/strong> przez <a href=\"https:\/\/www.packqc.com\/pl\/\"><em data-start=\"3906\" data-end=\"3924\">Instrumenty kom\u00f3rkowe<\/em><\/a> oferuje solidne, precyzyjne rozwi\u0105zanie. Ten zaawansowany system:<\/p><ul><li data-start=\"3992\" data-end=\"4056\">W pe\u0142ni zgodny z metodologi\u0105 testu si\u0142y zrywaj\u0105cej ISO 9187-1<\/li><li data-start=\"4059\" data-end=\"4121\">Zapewnia dok\u0142adne pomiary si\u0142y z wysok\u0105 powtarzalno\u015bci\u0105<\/li><li data-start=\"4124\" data-end=\"4192\">Obs\u0142uga programowalnych parametr\u00f3w testowych i automatyczne rejestrowanie danych<\/li><li data-start=\"4195\" data-end=\"4264\">\u0141atwe \u0142adowanie i wyr\u00f3wnywanie pr\u00f3bek minimalizuje b\u0142\u0119dy operatora.<\/li><\/ul><p data-start=\"4266\" data-end=\"4389\">Integruj\u0105c BST-01 z procesem kontroli jako\u015bci, mo\u017cna mie\u0107 pewno\u015b\u0107, \u017ce ka\u017cda ampu\u0142ka spe\u0142nia mi\u0119dzynarodowe standardy bezpiecze\u0144stwa i jako\u015bci.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7f23198 e-flex e-con-boxed e-con e-parent\" data-id=\"7f23198\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ac4a46d elementor-widget elementor-widget-heading\" data-id=\"ac4a46d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Podsumowanie: Zapewnienie zgodno\u015bci i bezpiecze\u0144stwa dzi\u0119ki testom ISO 9187-1<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c52c1ab e-flex e-con-boxed e-con e-parent\" data-id=\"c52c1ab\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ab39cb6 elementor-widget elementor-widget-text-editor\" data-id=\"ab39cb6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4471\" data-end=\"4881\">Przestrzeganie <strong data-start=\"4483\" data-end=\"4495\">Norma ISO 9187-1 <\/strong>to nie tylko spe\u0142nianie wymog\u00f3w regulacyjnych - to ochrona bezpiecze\u0144stwa pacjent\u00f3w i integralno\u015bci marki. Dzi\u0119ki precyzyjnym <strong data-start=\"4617\" data-end=\"4653\">Test z\u0142amania ampu\u0142ki ISO 9187-1<\/strong> procedury, producenci mog\u0105 zagwarantowa\u0107 sta\u0142\u0105 jako\u015b\u0107 produktu. The <a href=\"https:\/\/www.packqc.com\/pl\/product\/bst-01-glass-ampoule-break-force-tester\/\"><strong data-start=\"4726\" data-end=\"4760\">Tester przebicia ampu\u0142ki BST-01<\/strong><\/a> Cell Instruments zapewnia pewno\u015b\u0107 i mo\u017cliwo\u015bci techniczne potrzebne do dok\u0142adnego i wydajnego testowania zgodno\u015bci.<\/p><p data-start=\"4883\" data-end=\"5026\">Aby pozosta\u0107 liderem w dziedzinie kontroli jako\u015bci produkt\u00f3w farmaceutycznych, nale\u017cy wybra\u0107 odpowiednie oprzyrz\u0105dowanie i zrozumie\u0107 normy, takie jak <strong data-start=\"5000\" data-end=\"5012\">Norma ISO 9187<\/strong>-jest niezb\u0119dna.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Wprowadzenie do normy ISO 9187-1 dla ampu\u0142ek ISO 9187 to mi\u0119dzynarodowa norma o kluczowym znaczeniu, kt\u00f3ra okre\u015bla wymagania techniczne i wydajno\u015bciowe dla szklanych ampu\u0142ek stosowanych we wstrzykiwaczach medycznych. Norma zapewnia, \u017ce ampu\u0142ki s\u0105 bezpieczne, niezawodne i odpowiednie do przechowywania sterylnych produkt\u00f3w farmaceutycznych. Dotyczy ona przede wszystkim ampu\u0142ek wykonanych ze szk\u0142a i koncentruje si\u0119 na kluczowych w\u0142a\u015bciwo\u015bciach [...]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-6992","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/pl\/wp-json\/wp\/v2\/posts\/6992","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.packqc.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/pl\/wp-json\/wp\/v2\/comments?post=6992"}],"version-history":[{"count":0,"href":"https:\/\/www.packqc.com\/pl\/wp-json\/wp\/v2\/posts\/6992\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/pl\/wp-json\/wp\/v2\/media?parent=6992"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.packqc.com\/pl\/wp-json\/wp\/v2\/categories?post=6992"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.packqc.com\/pl\/wp-json\/wp\/v2\/tags?post=6992"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}