{"id":9585,"date":"2026-02-02T14:53:24","date_gmt":"2026-02-02T06:53:24","guid":{"rendered":"https:\/\/www.packqc.com\/products\/break-loose-force-and-glide-force-tester\/"},"modified":"2026-04-16T15:26:12","modified_gmt":"2026-04-16T07:26:12","slug":"break-loose-force-and-glide-force-tester","status":"publish","type":"products","link":"https:\/\/www.packqc.com\/pl\/products\/break-loose-force-and-glide-force-tester\/","title":{"rendered":"SSR-01 Tester oporu przesuwu strzykawki"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Testy si\u0142y rozlu\u017anienia i \u015blizgu<\/h2>\n\n\n\n<p>W ocenie wydajno\u015bci strzykawki, <strong data-start=\"496\" data-end=\"535\">testowanie si\u0142y \u015blizgowej i odrywania si\u0119<\/strong> odgrywa kluczow\u0105 rol\u0119 w ocenie p\u0142ynno\u015bci i niezawodno\u015bci ruchu t\u0142oka. Test ten okre\u015bla si\u0142\u0119 wymagan\u0105 do zainicjowania i utrzymania ruchu t\u0142oka strzykawki, zapewniaj\u0105c sp\u00f3jne podawanie leku i bezpiecze\u0144stwo pacjenta.<\/p>\n\n\n\n<p>Cell Instruments, wiod\u0105cy producent <strong data-start=\"826\" data-end=\"857\">sprz\u0119t do testowania materia\u0142\u00f3w<\/strong>, zapewnia zaawansowane <strong data-start=\"877\" data-end=\"925\">maszyny do testowania si\u0142y zrywaj\u0105cej i \u015blizgowej<\/strong> zaprojektowany zgodnie z <em data-start=\"948\" data-end=\"960\">Norma ISO 7886-1<\/em> standardy. Instrumenty te pomagaj\u0105 producentom, laboratoriom i specjalistom ds. kontroli jako\u015bci zapewni\u0107, \u017ce ich strzykawki spe\u0142niaj\u0105 mi\u0119dzynarodowe wymagania dotycz\u0105ce jako\u015bci i wydajno\u015bci.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">ISO 7886-1 i wydajno\u015b\u0107 strzykawki<\/h2>\n\n\n\n<p>Mi\u0119dzynarodowy standard <strong data-start=\"1233\" data-end=\"1247\">Norma ISO 7886-1<\/strong> okre\u015bla wymagania i metody testowania sterylnych strzykawek podsk\u00f3rnych do jednorazowego u\u017cytku. Za\u0142\u0105cznik E do normy okre\u015bla <strong data-start=\"1377\" data-end=\"1450\">metoda testowa do okre\u015blania si\u0142 wymaganych do dzia\u0142ania t\u0142oka<\/strong>, w tym zar\u00f3wno <em data-start=\"1467\" data-end=\"1486\">uwolni\u0107 si\u0142\u0119<\/em> I <em data-start=\"1491\" data-end=\"1506\">si\u0142a po\u015blizgu<\/em>.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"1513\" data-end=\"1534\">Si\u0142a zrywaj\u0105ca<\/strong> odnosi si\u0119 do <em data-start=\"1549\" data-end=\"1564\">si\u0142a pocz\u0105tkowa<\/em> wymagane do rozpocz\u0119cia ruchu t\u0142oka.<\/li>\n\n\n\n<li><strong data-start=\"1609\" data-end=\"1626\">Si\u0142a po\u015blizgu<\/strong> reprezentuje <em data-start=\"1642\" data-end=\"1660\">si\u0142a ci\u0105g\u0142a<\/em> potrzebne do utrzymania ruchu t\u0142oka przez ca\u0142y skok.<\/li>\n<\/ul>\n\n\n\n<p>Te dwa parametry s\u0105 krytycznymi wska\u017anikami jako\u015bci strzykawki, wp\u0142ywaj\u0105cymi na komfort u\u017cytkownika, dok\u0142adno\u015b\u0107 iniekcji i stabilno\u015b\u0107 przep\u0142ywu leku. Nadmierne lub niesp\u00f3jne si\u0142y mog\u0105 powodowa\u0107 gwa\u0142towne ruchy, b\u0142\u0119dy dozowania, a nawet awari\u0119 strzykawki.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Zasada testowania si\u0142y zrywaj\u0105cej i \u015blizgowej<br><small> -- ISO 7886-1 Za\u0142\u0105cznik E<\/small><\/h2>\n\n\n\n<p>Ten <strong data-start=\"2029\" data-end=\"2068\">testowanie si\u0142y \u015blizgowej i odrywania si\u0119<\/strong> proces wykorzystuje <strong data-start=\"2084\" data-end=\"2114\">mechaniczna maszyna testuj\u0105ca<\/strong> aby popchn\u0105\u0107 t\u0142ok strzykawki, jednocze\u015bnie mierz\u0105c i rejestruj\u0105c przy\u0142o\u017con\u0105 si\u0142\u0119. Test ocenia p\u0142ynno\u015b\u0107 dzia\u0142ania t\u0142oka w standardowych warunkach, takich jak temperatura i pr\u0119dko\u015b\u0107 przemieszczania.<\/p>\n\n\n\n<p>Podczas testu:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Strzykawka jest wype\u0142niona wod\u0105 o temperaturze <em data-start=\"2392\" data-end=\"2404\">(23 \u00b1 5)\u00b0C<\/em>.<\/li>\n\n\n\n<li>Dysza strzykawki \u0142\u0105czy si\u0119 ze zbiornikiem wody na kontrolowanym poziomie.<\/li>\n\n\n\n<li>Maszyna testuj\u0105ca przesuwa t\u0142ok ze sta\u0142\u0105 pr\u0119dko\u015bci\u0105 <em data-start=\"2548\" data-end=\"2568\">(100 \u00b1 5) mm\/min).<\/em><\/li>\n\n\n\n<li>System rejestruje:\n<ul class=\"wp-block-list\">\n<li>Ten <strong data-start=\"2605\" data-end=\"2631\">si\u0142a zrywaj\u0105ca (Fs)<\/strong> - si\u0142a wymagana do rozpocz\u0119cia ruchu t\u0142oka.<\/li>\n\n\n\n<li>Ten <strong data-start=\"2686\" data-end=\"2712\">\u015brednia si\u0142a po\u015blizgu (F)<\/strong> - \u015brednia si\u0142a podczas sta\u0142ego ruchu t\u0142oka.<\/li>\n\n\n\n<li>Ten <strong data-start=\"2772\" data-end=\"2796\">maksymalna si\u0142a (Fmax)<\/strong> - szczytowa si\u0142a zaobserwowana podczas ruchu.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<p>Parametry te s\u0105 wykre\u015blane jako <em style=\"font-size: 16px;\" data-start=\"2873\" data-end=\"2899\">krzywa si\u0142a-przemieszczenie<\/em>, zapewniaj\u0105c wyra\u017an\u0105 wizualizacj\u0119 charakterystyki pracy strzykawki.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">SSR-01 Tester oporu przesuwu strzykawki<\/h2>\n\n\n\n<p>Cell Instruments oferuje precyzyjnie zaprojektowane <strong data-start=\"3081\" data-end=\"3129\">maszyny do testowania si\u0142y zrywaj\u0105cej i \u015blizgowej<\/strong> kt\u00f3re s\u0105 zgodne z <em data-start=\"3147\" data-end=\"3159\">Norma ISO 7886-1<\/em> i powi\u0105zane standardy test\u00f3w farmaceutycznych.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Kluczowe cechy obejmuj\u0105:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"3598\" data-end=\"3616\">Wysoka precyzja<\/strong>: Dok\u0142adno\u015b\u0107 si\u0142y do <strong data-start=\"3639\" data-end=\"3647\">0.5%<\/strong> pe\u0142nego odczytu.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3673\" data-end=\"3698\">Szeroki zakres pr\u0119dko\u015bci testowej<\/strong>: Regulacja od <strong style=\"font-size: 16px;\" data-start=\"3716\" data-end=\"3735\">1 do 500 mm\/min<\/strong> aby dostosowa\u0107 si\u0119 do r\u00f3\u017cnych warunk\u00f3w testowych.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3778\" data-end=\"3805\">Pomiar trzech si\u0142<\/strong>: Automatycznie rejestruje si\u0142\u0119 zrywaj\u0105c\u0105, \u015bredni\u0105 si\u0142\u0119 po\u015blizgu i si\u0142\u0119 maksymaln\u0105.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3888\" data-end=\"3915\">Przyjazny dla u\u017cytkownika interfejs<\/strong>: <strong style=\"font-size: 16px;\" data-start=\"3917\" data-end=\"3935\">Sterowanie PLC<\/strong> z <strong style=\"font-size: 16px;\" data-start=\"3943\" data-end=\"3969\">7-calowy ekran dotykowy HMI<\/strong> dla p\u0142ynnej pracy.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3996\" data-end=\"4016\">Wbudowana drukarka<\/strong>: Zapewnia natychmiastowe wyniki test\u00f3w w celu dokumentacji i zapewnienia jako\u015bci.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"4093\" data-end=\"4116\">Ochrona przed przeci\u0105\u017ceniem<\/strong>: Zapewnia d\u0142ugoterminow\u0105 trwa\u0142o\u015b\u0107 i bezpiecze\u0144stwo operatora.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">G\u0142\u00f3wny parametr<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Kom\u00f3rka obci\u0105\u017ceniowa<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">200N (lub w razie potrzeby)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Pr\u0119dko\u015b\u0107 testu<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">1~500mm\/min<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Dok\u0142adno\u015b\u0107<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">0,01 mm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Moc<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">110~220 V<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Zastosowania i wp\u0142yw na bran\u017c\u0119<\/h2>\n\n\n\n<p>Testowanie si\u0142y zrywaj\u0105cej i si\u0142y po\u015blizgu ma kluczowe znaczenie w wielu sektorach:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"4294\" data-end=\"4313\">Urz\u0105dzenia medyczne<\/strong>: Zapewnia bezpiecze\u0144stwo i u\u017cyteczno\u015b\u0107 strzykawek dla pracownik\u00f3w s\u0142u\u017cby zdrowia i pacjent\u00f3w.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"4397\" data-end=\"4416\">Produkty farmaceutyczne<\/strong>: Weryfikuje sp\u00f3jno\u015b\u0107 produktu przed dystrybucj\u0105.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"4470\" data-end=\"4492\">Testy regulacyjne<\/strong>: Zapewnia dane niezb\u0119dne do zapewnienia zgodno\u015bci z <strong style=\"font-size: 16px;\" data-start=\"4538\" data-end=\"4560\"><a href=\"https:\/\/www.iso.org\/standard\/64790.html\" target=\"_blank\" rel=\"noopener nofollow\">Norma ISO 7886-1<\/a> testowanie<\/strong> wymagania.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"4577\" data-end=\"4596\">Kontrola jako\u015bci<\/strong>: Pomaga producentom utrzyma\u0107 wysokie standardy produkcji i zmniejszy\u0107 liczb\u0119 defekt\u00f3w.<\/li>\n<\/ul>\n\n\n\n<p>Dzi\u0119ki swojej precyzji i zgodno\u015bci z protoko\u0142ami ISO, SSR-01 jest idealnym rozwi\u0105zaniem dla <strong data-start=\"4759\" data-end=\"4810\">producenci strzykawek, firmy farmaceutyczne<\/strong>, I <strong data-start=\"4816\" data-end=\"4847\">agencje kontroli jako\u015bci<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Dlaczego warto wybra\u0107 Cell Instruments?<\/h2>\n\n\n\n<p>Jako do\u015bwiadczony producent specjalizuj\u0105cy si\u0119 w <strong data-start=\"4456\" data-end=\"4491\">Testowanie materia\u0142\u00f3w i automatyzacja<\/strong>, Cell Instruments zapewnia kompletne rozwi\u0105zania dla <strong data-start=\"4542\" data-end=\"4589\">testowanie luzu strzykawki i si\u0142y po\u015blizgu<\/strong>. \u0141\u0105czymy wysoce precyzyjn\u0105 in\u017cynieri\u0119, konfigurowalne oprogramowanie i specjalistyczne wsparcie techniczne, aby pom\u00f3c klientom spe\u0142ni\u0107 rygorystyczne standardy bran\u017cowe.<\/p>\n\n\n\n<p><strong data-start=\"4962\" data-end=\"5001\">Testowanie si\u0142y oderwania i \u015blizgu<\/strong> jest istotn\u0105 cz\u0119\u015bci\u0105 weryfikacji jako\u015bci strzykawki zgodnie z <em data-start=\"5068\" data-end=\"5080\">Norma ISO 7886-1<\/em>. Ma to bezpo\u015bredni wp\u0142yw na u\u017cyteczno\u015b\u0107, bezpiecze\u0144stwo i zgodno\u015b\u0107 z przepisami. Korzystaj\u0105c z profesjonalnych przyrz\u0105d\u00f3w testuj\u0105cych od <strong data-start=\"5195\" data-end=\"5215\">Instrumenty kom\u00f3rkowe<\/strong>, Laboratoria i producenci mog\u0105 uzyska\u0107 wiarygodne, dok\u0142adne i powtarzalne wyniki - zwi\u0119kszaj\u0105c zar\u00f3wno wydajno\u015b\u0107 produktu, jak i zaufanie klient\u00f3w.<\/p>","protected":false},"excerpt":{"rendered":"<p>Testy si\u0142y zrywaj\u0105cej i \u015blizgowej mierz\u0105 si\u0142\u0119 wymagan\u0105 do zainicjowania i utrzymania ruchu t\u0142oka strzykawki.<\/p>","protected":false},"featured_media":5356,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"product-category":[454,438,495,593],"product-tag":[],"class_list":["post-9585","products","type-products","status-publish","has-post-thumbnail","hentry","product-category-custom-lab-testing-instruments-manufacturer","product-category-medical-and-pharmaceutical-testing","product-category-pharmaceutical-testing","product-category-syringe-testing"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/pl\/wp-json\/wp\/v2\/products\/9585","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/pl\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.packqc.com\/pl\/wp-json\/wp\/v2\/types\/products"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/pl\/wp-json\/wp\/v2\/media\/5356"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/pl\/wp-json\/wp\/v2\/media?parent=9585"}],"wp:term":[{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/www.packqc.com\/pl\/wp-json\/wp\/v2\/product-category?post=9585"},{"taxonomy":"product-tag","embeddable":true,"href":"https:\/\/www.packqc.com\/pl\/wp-json\/wp\/v2\/product-tag?post=9585"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}