{"id":9582,"date":"2026-02-02T14:53:24","date_gmt":"2026-02-02T06:53:24","guid":{"rendered":"https:\/\/www.packqc.com\/products\/needle-toughness-tester\/"},"modified":"2026-04-16T10:11:17","modified_gmt":"2026-04-16T02:11:17","slug":"needle-toughness-tester","status":"publish","type":"products","link":"https:\/\/www.packqc.com\/ro\/products\/needle-toughness-tester\/","title":{"rendered":"NTT-01 Tester de duritate a acului"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Introducere \u00een rezisten\u021ba acului la rupere<\/h2>\n\n\n\n<p>Asigurarea <em data-start=\"453\" data-end=\"484\">rezisten\u021ba acului la rupere<\/em> este o parte esen\u021bial\u0103 a siguran\u021bei \u0219i fiabilit\u0103\u021bii dispozitivelor medicale, \u00een special pentru acele hipodermice. Ruperea \u00een timpul utiliz\u0103rii poate duce la r\u0103niri grave, contaminare sau defectarea produsului. Caracteristicile <strong data-start=\"720\" data-end=\"754\">NTT-01 Tester de duritate a acului<\/strong> de Cell Instruments ofer\u0103 o solu\u021bie precis\u0103, <b>ISO 9626 <\/b>solu\u021bie pentru verificarea rezisten\u021bei mecanice a tuburilor ac din o\u021bel inoxidabil.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">De ce este important\u0103 testarea rezisten\u021bei acului la rupere<\/h2>\n\n\n\n<p>\u00cen domeniul produc\u021biei de dispozitive medicale, \u00een special pentru ace \u0219i catetere, defec\u021biunile mecanice \u00een timpul utiliz\u0103rii prezint\u0103 riscuri semnificative. <em data-start=\"1443\" data-end=\"1474\">Rezisten\u021ba acului la rupere<\/em> trebuie s\u0103 fie validate pentru a asigura siguran\u021ba pacien\u021bilor \u0219i integritatea produsului. \u00cen conformitate cu <strong data-start=\"1554\" data-end=\"1571\"><a href=\"https:\/\/www.packqc.com\/ro\/product-category\/iso\/iso-9626\/\" target=\"_blank\" rel=\"noopener\">ISO 9626<\/a>:2016<\/strong>, tubulatura acului din o\u021bel inoxidabil utilizat\u0103 \u00een dispozitivele medicale trebuie supus\u0103 unor teste riguroase pentru a confirma durabilitatea sa \u00een condi\u021bii de stres.<\/p>\n\n\n\n<p>Acest standard, \u00een special <em data-start=\"1728\" data-end=\"1737\">Anexa C<\/em>, prezint\u0103 o metod\u0103 detaliat\u0103 de evaluare a <em data-start=\"1782\" data-end=\"1816\">rezisten\u021ba tubului la rupere<\/em>. Prin respectarea acestor cerin\u021be, produc\u0103torii nu numai c\u0103 asigur\u0103 conformitatea, dar \u0219i \u00eembun\u0103t\u0103\u021besc fiabilitatea produselor lor pe pia\u021b\u0103.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Rezisten\u021ba tuburilor la rupere - ISO 9626 Anexa C Metoda de testare<\/h2>\n\n\n\n<p>\u00cencercarea de \u00eencovoiere definit\u0103 \u00een <strong data-start=\"2060\" data-end=\"2080\"><a href=\"https:\/\/www.packqc.com\/ro\/standard\/iso-9626\/\" target=\"_blank\" data-type=\"standard\" data-id=\"9825\" rel=\"noreferrer noopener\">ISO 9626<\/a> Anexa C<\/strong> implic\u0103 fixarea unui cap\u0103t al tubului \u0219i aplicarea unei for\u021be controlate la o anumit\u0103 distan\u021b\u0103 pentru a \u00eendoi tubul \u00een ambele direc\u021bii \u00eentr-un unghi definit. Acest test simuleaz\u0103 solicit\u0103rile la care ar fi supus acul \u00een timpul utiliz\u0103rii clinice reale.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"2328\" data-end=\"2346\">Unghiuri de \u00eendoire<\/strong>:\n<ul class=\"wp-block-list\">\n<li><em style=\"font-size: 16px;\" data-start=\"2354\" data-end=\"2364\">(25 \u00b11)\u00b0<\/em> pentru tuburi cu pere\u021bi normali<\/li>\n\n\n\n<li><em style=\"font-size: 16px;\" data-start=\"2397\" data-end=\"2407\">(20 \u00b11)\u00b0<\/em> pentru tuburi cu pere\u021bi sub\u021biri<\/li>\n\n\n\n<li><em style=\"font-size: 16px;\" data-start=\"2437\" data-end=\"2447\">(15 \u00b11)\u00b0<\/em> pentru tuburi cu pere\u021bi foarte sub\u021biri \u0219i ultra-sub\u021biri<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"2497\" data-end=\"2512\">Cicluri de testare<\/strong>:<br>20 de cicluri complete de aplecare \u00eenainte \u0219i \u00eenapoi<\/li>\n\n\n\n<li><strong data-start=\"2572\" data-end=\"2590\">Frecven\u021ba de testare<\/strong>:<br>0,5 Hz<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\" style=\"margin-top:0;margin-bottom:0\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"Test de rezisten\u021b\u0103 cu ac cu interval la mijloc| \u00cendoire st\u00e2nga \u0219i dreapta\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/adX7tiXymqw?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<\/div><\/figure>\n\n\n\n<p>Dup\u0103 testare, acul este inspectat vizual pentru a detecta semne de rupere. Aceast\u0103 procedur\u0103 ofer\u0103 o metod\u0103 standardizat\u0103 de evaluare a rezisten\u021bei tuburilor, ajut\u00e2nd la asigurarea calit\u0103\u021bii \u0219i la respectarea reglement\u0103rilor.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Prezentarea testerului de duritate a acului NTT-01<\/h2>\n\n\n\n<p>The <strong data-start=\"2870\" data-end=\"2904\">NTT-01 <a href=\"https:\/\/www.packqc.com\/ro\/product\/needle-toughness-tester\/\">Tester de duritate a acului<\/a><\/strong> este conceput pentru a efectua metoda de testare ISO 9626 Anexa C cu o precizie ridicat\u0103 \u0219i controale u\u0219or de utilizat. Acesta permite produc\u0103torilor s\u0103 evalueze <em data-start=\"3048\" data-end=\"3079\">rezisten\u021ba acului la rupere<\/em> pe diferite grosimi ale pere\u021bilor tuburilor cu consecven\u021b\u0103 \u0219i precizie.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong data-start=\"3151\" data-end=\"3172\">Mecanism de lucru<\/strong><\/h3>\n\n\n\n<p>Dispozitivul fixeaz\u0103 rigid un cap\u0103t al tubului, aplic\u00e2nd \u00een acela\u0219i timp o for\u021b\u0103 \u00eentr-un punct desemnat pentru a \u00eendoi tubul la unghiul necesar. Sistemul inverseaz\u0103 apoi direc\u021bia \u0219i repet\u0103 procesul, gestion\u00e2nd automat frecven\u021ba testului \u0219i limitele unghiului.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Principalele caracteristici ale testerului de duritate a acului<\/h2>\n\n\n\n<p>Acest instrument este ideal pentru laboratoarele de cercetare, liniile de produc\u021bie \u0219i departamentele de control al calit\u0103\u021bii.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"3584\" data-end=\"3623\">Controlat de PLC cu ecran tactil HMI<\/strong>: Permite operarea \u0219i configurarea intuitiv\u0103.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3676\" data-end=\"3713\">Moduri de \u00eendoire \u00een dou\u0103 sensuri \u0219i \u00eentr-un singur sens<\/strong>: Suport\u0103 ambele cerin\u021be de testare.<\/li>\n\n\n\n<li><strong style=\"font-style: inherit;\" data-start=\"3752\" data-end=\"3782\">Parametri de testare ajustabili<\/strong>: Inclusiv frecven\u021ba, timpul de sta\u021bionare \u0219i unghiul de \u00eencovoiere.<\/li>\n\n\n\n<li><strong style=\"font-style: inherit;\" data-start=\"3840\" data-end=\"3869\">Func\u021bia de \u00eentoarcere automat\u0103<\/strong>: Asigur\u0103 integritatea testelor chiar \u0219i \u00een situa\u021bii de pan\u0103 de curent.<\/li>\n\n\n\n<li><strong style=\"font-style: inherit;\" data-start=\"3932\" data-end=\"3959\">Microimprimant\u0103 integrat\u0103<\/strong>: Pentru documentarea imediat\u0103 a rezultatelor testelor.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Parametrii tehnici principali<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Parametru<\/th><th>Specifica\u021bii<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">Modul de \u00eendoire<\/td><td class=\"has-text-align-center\" data-align=\"center\">Bidirec\u021bional, unidirec\u021bional<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Unghi de \u00eendoire<\/td><td class=\"has-text-align-center\" data-align=\"center\">15\u00b0, 20\u00b0, 25\u00b0<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Frecven\u021ba de testare<\/td><td class=\"has-text-align-center\" data-align=\"center\">0,5 Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Alimentare electric\u0103<\/td><td class=\"has-text-align-center\" data-align=\"center\">110~220V<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Configura\u021bie standard<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Tester de duritate a acului<\/li>\n\n\n\n<li>Calibru de precizie<\/li>\n\n\n\n<li>Cablu de alimentare<\/li>\n\n\n\n<li>Siguran\u021b\u0103<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">Aplica\u021bii \u00een domeniul medical \u0219i \u00een industriile conexe<\/h2>\n\n\n\n<p>NTT-01 este utilizat \u00een principal pentru testarea acelor hipodermice, cateterelor \u0219i tuburilor \u00een <strong data-start=\"4656\" data-end=\"4683\">medicale, farmaceutice<\/strong>, \u0219i <strong data-start=\"4689\" data-end=\"4714\">fabricarea seringilor<\/strong> sectoare. De asemenea, este aplicabil pe scar\u0103 larg\u0103 pentru <strong data-start=\"4756\" data-end=\"4787\">agen\u021bii de control al calit\u0103\u021bii<\/strong>, asigur\u00e2nd conformitatea produselor finale cu standardele interna\u021bionale de siguran\u021b\u0103, cum ar fi <a href=\"https:\/\/www.iso.org\/standard\/60480.html\" target=\"_blank\" rel=\"noopener nofollow\"><em data-start=\"4859\" data-end=\"4869\">ISO 9626<\/em><\/a>.<\/p>\n\n\n\n<p>Pentru companiile care doresc s\u0103 <strong data-start=\"4899\" data-end=\"4931\">personalizarea procedurilor de testare<\/strong> sau s\u0103 automatizeze o parte a procesului de asigurare a calit\u0103\u021bii, Cell Instruments ofer\u0103 solu\u021bii personalizate concepute pentru a eficientiza opera\u021biunile f\u0103r\u0103 a compromite precizia.<\/p>\n\n\n\n<p>Men\u021binerea <em data-start=\"5129\" data-end=\"5160\">rezisten\u021ba acului la rupere<\/em> nu este doar o necesitate de reglementare - este o chestiune de integritate a produsului \u0219i de siguran\u021b\u0103 a utilizatorului. Cu <strong data-start=\"5256\" data-end=\"5290\">NTT-01 Tester de duritate a acului<\/strong>, Cell Instruments ofer\u0103 o solu\u021bie avansat\u0103 \u0219i conform\u0103 pentru produc\u0103torii care urm\u0103resc excelen\u021ba. Indiferent dac\u0103 testa\u021bi tuburi medicale standard sau componente personalizate, NTT-01 asigur\u0103 performan\u021b\u0103 constant\u0103 \u0219i lini\u0219te sufleteasc\u0103.<\/p>\n\n\n\n<p>Pentru a afla mai multe despre modul \u00een care NTT-01 v\u0103 poate \u00eembun\u0103t\u0103\u021bi standardele de testare sau pentru a discuta <strong data-start=\"5617\" data-end=\"5646\">transformarea automatiz\u0103rii<\/strong> servicii, contact <strong data-start=\"5665\" data-end=\"5695\"><a href=\"https:\/\/www.packqc.com\/ro\/\" target=\"_blank\" rel=\"noopener\">Instrumente celulare<\/a> Co., Ltd.<\/strong> ast\u0103zi.<\/p>","protected":false},"excerpt":{"rendered":"<p>Ensuring needle resistance to breakage is a critical part of medical device safety and reliability, particularly for hypodermic needles.<\/p>","protected":false},"featured_media":5285,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"product-category":[456,579,434,580,438,581,593],"product-tag":[],"class_list":["post-9582","products","type-products","status-publish","has-post-thumbnail","hentry","product-category-gb","product-category-gb-t-18457","product-category-iso","product-category-iso-9626","product-category-medical-and-pharmaceutical-testing","product-category-needle-toughness-tester","product-category-syringe-testing"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/ro\/wp-json\/wp\/v2\/products\/9582","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/ro\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.packqc.com\/ro\/wp-json\/wp\/v2\/types\/products"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/ro\/wp-json\/wp\/v2\/media\/5285"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/ro\/wp-json\/wp\/v2\/media?parent=9582"}],"wp:term":[{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/www.packqc.com\/ro\/wp-json\/wp\/v2\/product-category?post=9582"},{"taxonomy":"product-tag","embeddable":true,"href":"https:\/\/www.packqc.com\/ro\/wp-json\/wp\/v2\/product-tag?post=9582"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}