{"id":9585,"date":"2026-02-02T14:53:24","date_gmt":"2026-02-02T06:53:24","guid":{"rendered":"https:\/\/www.packqc.com\/products\/break-loose-force-and-glide-force-tester\/"},"modified":"2026-04-16T15:26:12","modified_gmt":"2026-04-16T07:26:12","slug":"break-loose-force-and-glide-force-tester","status":"publish","type":"products","link":"https:\/\/www.packqc.com\/ro\/products\/break-loose-force-and-glide-force-tester\/","title":{"rendered":"SSR-01 Tester de rezisten\u021b\u0103 la alunecare a seringii"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Testarea for\u021bei de rupere \u0219i alunecare<\/h2>\n\n\n\n<p>\u00cen evaluarea performan\u021bei seringii, <strong data-start=\"496\" data-end=\"535\">testarea for\u021bei de desfacere \u0219i alunecare<\/strong> joac\u0103 un rol crucial \u00een evaluarea fluidit\u0103\u021bii \u0219i fiabilit\u0103\u021bii mi\u0219c\u0103rii pistonului. Acest test determin\u0103 for\u021ba necesar\u0103 pentru ini\u021bierea \u0219i men\u021binerea mi\u0219c\u0103rii pistonului seringii, asigur\u00e2nd administrarea consecvent\u0103 a medicamentului \u0219i siguran\u021ba pacientului.<\/p>\n\n\n\n<p>Cell Instruments, un produc\u0103tor de top de <strong data-start=\"826\" data-end=\"857\">echipamente de testare a materialelor<\/strong>, ofer\u0103 func\u021bii avansate <strong data-start=\"877\" data-end=\"925\">ma\u0219ini de testare a for\u021bei de desprindere \u0219i de alunecare<\/strong> concepute \u00een conformitate cu <em data-start=\"948\" data-end=\"960\">ISO 7886-1<\/em> standarde. Aceste instrumente ajut\u0103 produc\u0103torii, laboratoarele \u0219i profesioni\u0219tii din domeniul controlului calit\u0103\u021bii s\u0103 se asigure c\u0103 seringile lor \u00eendeplinesc cerin\u021bele interna\u021bionale de calitate \u0219i performan\u021b\u0103.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">ISO 7886-1 \u0219i performan\u021ba seringii<\/h2>\n\n\n\n<p>Standardul interna\u021bional <strong data-start=\"1233\" data-end=\"1247\">ISO 7886-1<\/strong> specific\u0103 cerin\u021bele \u0219i metodele de testare pentru seringile hipodermice sterile de unic\u0103 folosin\u021b\u0103. Anexa E la standard prezint\u0103 <strong data-start=\"1377\" data-end=\"1450\">metod\u0103 de testare pentru determinarea for\u021belor necesare pentru ac\u021bionarea pistonului<\/strong>, inclusiv at\u00e2t <em data-start=\"1467\" data-end=\"1486\">rupe for\u021ba liber\u0103<\/em> \u015fi <em data-start=\"1491\" data-end=\"1506\">for\u021b\u0103 de alunecare<\/em>.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"1513\" data-end=\"1534\">For\u021ba de desprindere<\/strong> se refer\u0103 la <em data-start=\"1549\" data-end=\"1564\">for\u021ba ini\u021bial\u0103<\/em> necesar\u0103 pentru a porni mi\u0219carea pistonului.<\/li>\n\n\n\n<li><strong data-start=\"1609\" data-end=\"1626\">For\u021ba de alunecare<\/strong> reprezint\u0103 <em data-start=\"1642\" data-end=\"1660\">for\u021b\u0103 continu\u0103<\/em> necesare pentru a men\u021bine mi\u0219carea pistonului pe toat\u0103 durata cursei.<\/li>\n<\/ul>\n\n\n\n<p>Ace\u0219ti doi parametri sunt indicatori critici ai calit\u0103\u021bii seringii, influen\u021b\u00e2nd confortul utilizatorului, precizia injec\u021biei \u0219i stabilitatea fluxului de medicament. For\u021bele excesive sau inconsecvente pot duce la mi\u0219c\u0103ri sacadate, erori de dozare sau chiar defectarea seringii.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Principiul test\u0103rii for\u021bei de desprindere \u0219i de alunecare<br><small> -- ISO 7886-1 Anexa E<\/small><\/h2>\n\n\n\n<p>The <strong data-start=\"2029\" data-end=\"2068\">testarea for\u021bei de desfacere \u0219i alunecare<\/strong> utilizeaz\u0103 un proces <strong data-start=\"2084\" data-end=\"2114\">ma\u0219in\u0103 de testare mecanic\u0103<\/strong> pentru a \u00eempinge pistonul seringii \u00een timp ce se m\u0103soar\u0103 \u0219i se \u00eenregistreaz\u0103 for\u021ba aplicat\u0103. Testul evalueaz\u0103 c\u00e2t de u\u0219or func\u021bioneaz\u0103 pistonul \u00een condi\u021bii standardizate, cum ar fi temperatura \u0219i viteza de deplasare.<\/p>\n\n\n\n<p>\u00cen timpul testului:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Seringa este umplut\u0103 cu ap\u0103 men\u021binut\u0103 la <em data-start=\"2392\" data-end=\"2404\">(23 \u00b1 5)\u00b0C<\/em>.<\/li>\n\n\n\n<li>Duza seringii se conecteaz\u0103 la un rezervor de ap\u0103 la un nivel controlat.<\/li>\n\n\n\n<li>Ma\u0219ina de testare mi\u0219c\u0103 pistonul la o vitez\u0103 constant\u0103 de <em data-start=\"2548\" data-end=\"2568\">(100 \u00b1 5) mm\/min).<\/em><\/li>\n\n\n\n<li>Sistemul \u00eenregistreaz\u0103:\n<ul class=\"wp-block-list\">\n<li>The <strong data-start=\"2605\" data-end=\"2631\">for\u021ba de desprindere (Fs)<\/strong> - for\u021ba necesar\u0103 pentru a porni mi\u0219carea pistonului.<\/li>\n\n\n\n<li>The <strong data-start=\"2686\" data-end=\"2712\">for\u021ba medie de planare (F)<\/strong> - for\u021ba medie \u00een timpul mi\u0219c\u0103rii constante a pistonului.<\/li>\n\n\n\n<li>The <strong data-start=\"2772\" data-end=\"2796\">for\u021ba maxim\u0103 (Fmax)<\/strong> - for\u021ba maxim\u0103 observat\u0103 \u00een timpul mi\u0219c\u0103rii.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<p>Ace\u0219ti parametri sunt reprezenta\u021bi grafic ca o <em style=\"font-size: 16px;\" data-start=\"2873\" data-end=\"2899\">curba for\u021b\u0103-deplasare<\/em>, oferind o vizualizare clar\u0103 a caracteristicilor de performan\u021b\u0103 ale seringii.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">SSR-01 Tester de rezisten\u021b\u0103 la alunecare a seringii<\/h2>\n\n\n\n<p>Cell Instruments ofer\u0103 tehnologie de precizie <strong data-start=\"3081\" data-end=\"3129\">ma\u0219ini de testare a for\u021bei de desprindere \u0219i de alunecare<\/strong> care sunt conforme cu <em data-start=\"3147\" data-end=\"3159\">ISO 7886-1<\/em> \u0219i standardele de testare farmaceutic\u0103 aferente.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Caracteristicile cheie includ:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"3598\" data-end=\"3616\">Precizie ridicat\u0103<\/strong>: Precizia for\u021bei p\u00e2n\u0103 la <strong data-start=\"3639\" data-end=\"3647\">0.5%<\/strong> de citire la scar\u0103 complet\u0103.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3673\" data-end=\"3698\">Gam\u0103 larg\u0103 de viteze de testare<\/strong>: Reglabil de la <strong style=\"font-size: 16px;\" data-start=\"3716\" data-end=\"3735\">1 p\u00e2n\u0103 la 500 mm\/min<\/strong> pentru a se adapta diferitelor condi\u021bii de testare.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3778\" data-end=\"3805\">M\u0103surarea cu trei for\u021be<\/strong>: Capteaz\u0103 automat for\u021ba de desprindere, for\u021ba medie de alunecare \u0219i for\u021ba maxim\u0103.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3888\" data-end=\"3915\">Interfa\u021b\u0103 u\u0219or de utilizat<\/strong>: <strong style=\"font-size: 16px;\" data-start=\"3917\" data-end=\"3935\">Controlat de PLC<\/strong> cu un <strong style=\"font-size: 16px;\" data-start=\"3943\" data-end=\"3969\">Ecran tactil HMI de 7 inchi<\/strong> pentru o func\u021bionare f\u0103r\u0103 \u00eentreruperi.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3996\" data-end=\"4016\">Imprimant\u0103 \u00eencorporat\u0103<\/strong>: Furnizeaz\u0103 rezultate imediate ale testelor pentru documentare \u0219i asigurarea calit\u0103\u021bii.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"4093\" data-end=\"4116\">Protec\u021bie la suprasarcin\u0103<\/strong>: Asigur\u0103 durabilitatea pe termen lung \u0219i siguran\u021ba operatorului.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Parametrul principal<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Celul\u0103 de sarcin\u0103<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">200N (sau dup\u0103 cum este necesar)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Viteza de testare<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">1~500mm\/min<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Precizie<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">0,01 mm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Putere<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">110~220V<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Aplica\u021bii \u0219i impactul asupra industriei<\/h2>\n\n\n\n<p>Testarea for\u021bei de desprindere \u0219i a for\u021bei de alunecare este esen\u021bial\u0103 \u00een mai multe sectoare:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"4294\" data-end=\"4313\">Dispozitive medicale<\/strong>: Asigur\u0103 siguran\u021ba \u0219i u\u0219urin\u021ba de utilizare a seringii pentru profesioni\u0219tii din domeniul s\u0103n\u0103t\u0103\u021bii \u0219i pacien\u021bi.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"4397\" data-end=\"4416\">Produse farmaceutice<\/strong>: Verific\u0103 consisten\u021ba produselor \u00eenainte de distribu\u021bie.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"4470\" data-end=\"4492\">Teste de reglementare<\/strong>: Furnizeaz\u0103 datele necesare pentru conformitatea cu <strong style=\"font-size: 16px;\" data-start=\"4538\" data-end=\"4560\"><a href=\"https:\/\/www.iso.org\/standard\/64790.html\" target=\"_blank\" rel=\"noopener nofollow\">ISO 7886-1<\/a> testare<\/strong> cerin\u021be.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"4577\" data-end=\"4596\">Controlul calit\u0103\u021bii<\/strong>: Ajut\u0103 produc\u0103torii s\u0103 men\u021bin\u0103 standarde ridicate de produc\u021bie \u0219i s\u0103 reduc\u0103 rata defectelor.<\/li>\n<\/ul>\n\n\n\n<p>Datorit\u0103 preciziei sale \u0219i respect\u0103rii protocoalelor ISO, SSR-01 este ideal pentru <strong data-start=\"4759\" data-end=\"4810\">produc\u0103tori de seringi, companii farmaceutice<\/strong>, \u0219i <strong data-start=\"4816\" data-end=\"4847\">agen\u021bii de control al calit\u0103\u021bii<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">De ce s\u0103 alege\u021bi instrumentele celulare?<\/h2>\n\n\n\n<p>\u00cen calitate de produc\u0103tor cu experien\u021b\u0103 specializat \u00een <strong data-start=\"4456\" data-end=\"4491\">testarea \u0219i automatizarea materialelor<\/strong>, Cell Instruments ofer\u0103 solu\u021bii complete pentru <strong data-start=\"4542\" data-end=\"4589\">testarea for\u021bei de dezlipire \u0219i de alunecare a seringii<\/strong>. Combin\u0103m ingineria de \u00eenalt\u0103 precizie, software-ul personalizabil \u0219i asisten\u021ba tehnic\u0103 de specialitate pentru a ajuta clien\u021bii s\u0103 \u00eendeplineasc\u0103 standardele stricte ale industriei.<\/p>\n\n\n\n<p><strong data-start=\"4962\" data-end=\"5001\">Testarea for\u021bei de eliberare \u0219i alunecare<\/strong> este o parte esen\u021bial\u0103 a verific\u0103rii calit\u0103\u021bii seringilor \u00een conformitate cu <em data-start=\"5068\" data-end=\"5080\">ISO 7886-1<\/em>. Aceasta afecteaz\u0103 \u00een mod direct capacitatea de utilizare, siguran\u021ba \u0219i conformitatea cu reglement\u0103rile. Prin utilizarea instrumentelor profesionale de testare de la <strong data-start=\"5195\" data-end=\"5215\">Instrumente celulare<\/strong>, laboratoarele \u0219i produc\u0103torii pot ob\u021bine rezultate fiabile, precise \u0219i reproductibile - \u00eembun\u0103t\u0103\u021bind at\u00e2t performan\u021ba produselor, c\u00e2t \u0219i \u00eencrederea clien\u021bilor.<\/p>","protected":false},"excerpt":{"rendered":"<p>Testarea for\u021bei de desprindere \u0219i de alunecare m\u0103soar\u0103 for\u021ba necesar\u0103 pentru ini\u021bierea \u0219i men\u021binerea mi\u0219c\u0103rii pistonului seringii.<\/p>","protected":false},"featured_media":5356,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"product-category":[454,438,495,593],"product-tag":[],"class_list":["post-9585","products","type-products","status-publish","has-post-thumbnail","hentry","product-category-custom-lab-testing-instruments-manufacturer","product-category-medical-and-pharmaceutical-testing","product-category-pharmaceutical-testing","product-category-syringe-testing"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/ro\/wp-json\/wp\/v2\/products\/9585","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/ro\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.packqc.com\/ro\/wp-json\/wp\/v2\/types\/products"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/ro\/wp-json\/wp\/v2\/media\/5356"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/ro\/wp-json\/wp\/v2\/media?parent=9585"}],"wp:term":[{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/www.packqc.com\/ro\/wp-json\/wp\/v2\/product-category?post=9585"},{"taxonomy":"product-tag","embeddable":true,"href":"https:\/\/www.packqc.com\/ro\/wp-json\/wp\/v2\/product-tag?post=9585"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}