{"id":9861,"date":"2026-02-24T15:11:46","date_gmt":"2026-02-24T07:11:46","guid":{"rendered":"https:\/\/www.packqc.com\/standard\/iso-7886-1-2\/"},"modified":"2026-04-16T09:54:22","modified_gmt":"2026-04-16T01:54:22","slug":"iso-7886-1","status":"publish","type":"standard","link":"https:\/\/www.packqc.com\/ro\/standard\/iso-7886-1\/","title":{"rendered":"ISO 7886-1"},"content":{"rendered":"<h2 class=\"wp-block-heading\">\u00cen\u021belegerea ISO 7886-1<\/h2>\n\n\n\n<p>The <strong data-start=\"1069\" data-end=\"1083\">ISO 7886-1<\/strong> specific\u0103 criteriile de proiectare, performan\u021b\u0103 \u0219i testare pentru seringile de unic\u0103 folosin\u021b\u0103 utilizate \u00een aplica\u021bii medicale \u0219i de laborator. Se asigur\u0103 c\u0103 seringile \u00ee\u0219i men\u021bin integritatea \u00een condi\u021bii mecanice, de presiune \u0219i de scurgere.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Detectarea scurgerilor \u00een seringi - Test de scurgere de aer \u0219i lichid<\/h2>\n\n\n\n<p>Detectarea scurgerilor este unul dintre cele mai importante teste specificate \u00een <strong data-start=\"2024\" data-end=\"2041\">Anexele B \u0219i D<\/strong> din ISO 7886-1. Acesta determin\u0103 dac\u0103 apar scurgeri de aer sau de lichid pe l\u00e2ng\u0103 opritorul pistonului sau pe l\u00e2ng\u0103 cilindru \u00een anumite condi\u021bii de presiune.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Anexa B - Test de scurgere a aerului<\/h3>\n\n\n\n<p><strong data-start=\"2179\" data-end=\"2209\">Test de etan\u0219eitate la aer (anexa B)<\/strong> necesit\u0103 ca seringa s\u0103 fie par\u021bial umplut\u0103 cu ap\u0103 \u0219i supus\u0103 unui vid de <strong data-start=\"2294\" data-end=\"2327\">88 kPa sub presiunea ambiant\u0103<\/strong>. Orice bule de aer vizibile sau sc\u0103dere de presiune indic\u0103 o scurgere sau o etan\u0219are necorespunz\u0103toare. <strong data-start=\"2405\" data-end=\"2452\">Cell Instruments SLT-02 Tester de scurgere a seringii<\/strong> simuleaz\u0103 perfect acest proces, permi\u021b\u00e2nd operatorilor s\u0103 aplice o presiune de vid controlat\u0103 \u0219i s\u0103 monitorizeze cu exactitate scurgerile.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Anexa D - Test de scurgere a lichidului<\/h3>\n\n\n\n<p><strong data-start=\"2577\" data-end=\"2613\">\u00cencerc\u0103ri de etan\u0219eitate la lichide (anexa D)<\/strong> evalueaz\u0103 integritatea etan\u0219\u0103rii seringii atunci c\u00e2nd este comprimat\u0103 \u00een interior. Folosind dispozitive precum <strong data-start=\"2702\" data-end=\"2763\">Cell Instruments SPPT-01 Tester de presiune pozitiv\u0103 a seringii<\/strong>, seringa este umplut\u0103, sigilat\u0103 \u0219i presurizat\u0103 p\u00e2n\u0103 la <strong data-start=\"2818\" data-end=\"2829\">300 kPa<\/strong>, reproduc\u00e2nd condi\u021biile reale de utilizare. Observarea scurgerilor de ap\u0103 identific\u0103 eventualele defecte de fabrica\u021bie.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Anexa E<small>-- Testarea for\u021bei de alunecare a seringii \u0219i testarea for\u021bei de desprindere<\/small><\/h3>\n\n\n\n<p>Func\u021bionarea f\u0103r\u0103 probleme a pistonului seringii este vital\u0103 pentru administrarea precis\u0103 a medicamentelor \u0219i pentru confortul pacientului. <strong data-start=\"3249\" data-end=\"3260\">Anexa E<\/strong> din ISO 7886-1 define\u0219te procedurile de m\u0103surare a <strong data-start=\"3312\" data-end=\"3354\">for\u021bele necesare pentru ac\u021bionarea pistonului<\/strong>-inclusiv <em data-start=\"3365\" data-end=\"3384\">rupe for\u021ba liber\u0103<\/em> (mi\u0219carea ini\u021bial\u0103) \u0219i <em data-start=\"3408\" data-end=\"3421\">for\u021ba de alunecare<\/em> (mi\u0219care continu\u0103).<\/p>\n\n\n\n<p>Folosind a <strong data-start=\"3448\" data-end=\"3478\">ma\u0219in\u0103 de testare mecanic\u0103<\/strong>, pistonul este deplasat la o vitez\u0103 controlat\u0103 de <strong data-start=\"3526\" data-end=\"3544\">100 \u00b1 5 mm\/min<\/strong>, \u00een timp ce valorile for\u021bei sunt \u00eenregistrate continuu. For\u021ba excesiv\u0103 sau inconsecvent\u0103 poate indica lubrifierea slab\u0103, incompatibilitatea materialului sau deformarea \u021bevii.<\/p>\n\n\n\n<p>The <strong data-start=\"3709\" data-end=\"3763\">Cell Instruments SSR-01 Tester de for\u021b\u0103 de alunecare a seringii<\/strong> permite determinarea precis\u0103 a:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"3801\" data-end=\"3828\">For\u021ba de desprindere (fs):<\/strong> For\u021ba necesar\u0103 pentru a porni mi\u0219carea pistonului<\/li>\n\n\n\n<li><strong data-start=\"3872\" data-end=\"3902\">For\u021ba de alunecare sus\u021binut\u0103 (F):<\/strong> For\u021ba medie \u00een timpul deplas\u0103rii pistonului<\/li>\n\n\n\n<li><strong data-start=\"3943\" data-end=\"3974\">For\u021ba maxim\u0103 de alunecare (Fmax):<\/strong> For\u021ba de rezisten\u021b\u0103 maxim\u0103 observat\u0103<\/li>\n<\/ul>\n\n\n\n<p>Aceste date asigur\u0103 faptul c\u0103 seringile ofer\u0103 performan\u021be constante \u0219i \u00eendeplinesc cerin\u021bele ergonomice definite \u00een ISO 7886-1.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Testarea seringilor hipodermice \u0219i compatibilitatea acelor<\/h2>\n\n\n\n<p>Dincolo de evaluarea cilindrului seringii \u0219i a pistonului, <strong data-start=\"4236\" data-end=\"4250\">ISO 7886-1<\/strong> func\u021bioneaz\u0103 \u00een colaborare cu <strong data-start=\"4277\" data-end=\"4289\">ISO 7864<\/strong>, care reglementeaz\u0103 <em data-start=\"4305\" data-end=\"4348\">ace hipodermice sterile de unic\u0103 folosin\u021b\u0103<\/em>. Conexiunea corect\u0103 \u00eentre sering\u0103 \u0219i ac este verificat\u0103 folosind fitinguri conice conforme cu <strong data-start=\"4445\" data-end=\"4460\">ISO 80369-7<\/strong>. Testarea compatibilit\u0103\u021bii asigur\u0103 o potrivire sigur\u0103, prevenind scurgerile \u00een timpul transferului de fluide. Acest aspect este vital \u00een <a href=\"https:\/\/www.packqc.com\/ro\/solutions\/syringe-testing\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"4572\" data-end=\"4602\">testarea seringilor hipodermice<\/strong><\/a> unde injec\u021bia de precizie este obligatorie \u00een industria medical\u0103 \u0219i farmaceutic\u0103.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Echipament de testare a seringilor de la Cell Instruments<\/h2>\n\n\n\n<p><strong data-start=\"4752\" data-end=\"4782\">Cell Instruments Co., Ltd.<\/strong> ofer\u0103 solu\u021bii complete de testare a seringilor, \u00een deplin\u0103 concordan\u021b\u0103 cu cerin\u021bele ISO 7886-1:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"4879\" data-end=\"4910\"><a href=\"https:\/\/www.packqc.com\/ro\/product\/syringe-leak-testing-machine\/\" target=\"_blank\" rel=\"noopener\">SLT-02 Tester de scurgere a seringii<\/a>:<\/strong> Efectueaz\u0103 detectarea precis\u0103 a scurgerilor de aer pe baz\u0103 de vid.<\/li>\n\n\n\n<li><strong data-start=\"4968\" data-end=\"5013\"><a href=\"https:\/\/www.packqc.com\/ro\/product\/syringe-liquid-leak-tester-iso-7886-1\/\" target=\"_blank\" rel=\"noopener\">SPPT-01 Tester de presiune pozitiv\u0103 pentru sering\u0103<\/a>:<\/strong> Evalueaz\u0103 etan\u0219eitatea dopului cu piston sub compresie \u0219i rezisten\u021ba la scurgerea lichidelor.<\/li>\n\n\n\n<li><strong data-start=\"5101\" data-end=\"5139\"><a href=\"https:\/\/www.packqc.com\/ro\/product\/break-loose-force-and-glide-force-tester\/\" target=\"_blank\" rel=\"noopener\">SSR-01 Tester de for\u021b\u0103 de alunecare a seringii<\/a>:<\/strong> Determin\u0103 for\u021bele de desprindere \u0219i de alunecare cu o precizie ridicat\u0103 pentru validarea performan\u021bei.<\/li>\n<\/ul>\n\n\n\n<p>Fiecare instrument este proiectat cu capacit\u0103\u021bi avansate de automatizare \u0219i achizi\u021bie de date digitale, asigur\u00e2nd rezultate precise \u0219i repetabile, simplific\u00e2nd \u00een acela\u0219i timp fluxurile de lucru pentru controlul calit\u0103\u021bii. Automatizarea testelor personalizate \u0219i caracteristicile de \u00eenregistrare a datelor fac ca aceste dispozitive s\u0103 fie potrivite pentru produc\u0103torii de dispozitive medicale, laboratoare \u0219i departamente de asigurare a calit\u0103\u021bii.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Contacta\u021bi-ne pentru a ob\u021bine solu\u021bia de testare ISO 7886-1 <\/h2>\n\n\n\n<p>Conformitatea cu <a href=\"https:\/\/www.iso.org\/standard\/64790.html\" target=\"_blank\" rel=\"noopener nofollow\"><strong data-start=\"5609\" data-end=\"5623\">ISO 7886-1<\/strong><\/a> este esen\u021bial\u0103 pentru produc\u0103torii care doresc s\u0103 produc\u0103 produse sigure, eficiente \u0219i fiabile <strong data-start=\"5703\" data-end=\"5734\">seringi hipodermice sterile<\/strong>. Prin integrarea metodelor de testare standardizate - cum ar fi <strong data-start=\"5788\" data-end=\"5819\">detectarea scurgerilor \u00een seringi<\/strong>, <strong data-start=\"5821\" data-end=\"5852\">testarea for\u021bei de alunecare a seringii<\/strong>, \u0219i <strong data-start=\"5858\" data-end=\"5893\">testarea for\u021bei de alunecare<\/strong>-echipele de asigurare a calit\u0103\u021bii pot verifica integritatea produsului \u0219i consecven\u021ba performan\u021bei.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u00cen\u021belegerea standardului ISO 7886-1 Standardul ISO 7886-1 specific\u0103 criteriile de proiectare, performan\u021b\u0103 \u0219i testare pentru seringile de unic\u0103 folosin\u021b\u0103 utilizate \u00een aplica\u021bii medicale \u0219i de laborator. Acesta garanteaz\u0103 c\u0103 seringile \u00ee\u0219i men\u021bin integritatea \u00een condi\u021bii mecanice, de presiune \u0219i de scurgere. Detectarea scurgerilor \u00een seringi - Test de scurgere a aerului \u0219i lichidului Detectarea scurgerilor este unul dintre cele mai importante teste specificate [...]<\/p>","protected":false},"featured_media":8033,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"standard-category":[612],"class_list":["post-9861","standard","type-standard","status-publish","has-post-thumbnail","hentry","standard-category-iso"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/ro\/wp-json\/wp\/v2\/standard\/9861","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/ro\/wp-json\/wp\/v2\/standard"}],"about":[{"href":"https:\/\/www.packqc.com\/ro\/wp-json\/wp\/v2\/types\/standard"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/ro\/wp-json\/wp\/v2\/media\/8033"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/ro\/wp-json\/wp\/v2\/media?parent=9861"}],"wp:term":[{"taxonomy":"standard-category","embeddable":true,"href":"https:\/\/www.packqc.com\/ro\/wp-json\/wp\/v2\/standard-category?post=9861"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}