{"id":9290,"date":"2026-02-02T11:23:36","date_gmt":"2026-02-02T03:23:36","guid":{"rendered":"https:\/\/www.packqc.com\/applications\/needle-sharpness-testing\/"},"modified":"2026-03-25T11:38:49","modified_gmt":"2026-03-25T03:38:49","slug":"needle-sharpness-testing","status":"publish","type":"applications","link":"https:\/\/www.packqc.com\/sq\/applications\/needle-sharpness-testing\/","title":{"rendered":"Testimi i mpreht\u00ebsis\u00eb s\u00eb gjilp\u00ebr\u00ebs"},"content":{"rendered":"<p>Testimi i mpreht\u00ebsis\u00eb s\u00eb gjilp\u00ebrave \u00ebsht\u00eb nj\u00eb pjes\u00eb kritike e sigurimit t\u00eb cil\u00ebsis\u00eb p\u00ebr gjilp\u00ebrat mjek\u00ebsore, kirurgjikale dhe t\u00eb akupunktur\u00ebs. Ai ndikon drejtp\u00ebrdrejt n\u00eb rehati t\u00eb pacientit, sakt\u00ebsin\u00eb e injeksionit dhe sigurin\u00eb. Ky testim p\u00ebrfshin vler\u00ebsimin e <strong data-start=\"763\" data-end=\"784\">forc\u00eb dep\u00ebrtuese<\/strong> t\u00eb maj\u00ebs s\u00eb gjilp\u00ebr\u00ebs dhe aft\u00ebsis\u00eb s\u00eb saj p\u00ebr t'u rezistuar thyerjes ose deformimit. Standarde t\u00eb tilla si <strong data-start=\"872\" data-end=\"886\">ASTM F3014<\/strong>, <strong data-start=\"888\" data-end=\"901\">ISO 17218<\/strong>, <strong data-start=\"903\" data-end=\"918\">ISO 11040-4<\/strong>, dhe <strong data-start=\"924\" data-end=\"936\">ISO 7864<\/strong> ofroni metoda rigoroze testimi p\u00ebr t\u00eb siguruar rezultate t\u00eb besueshme dhe t\u00eb riprodhueshme.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pse \u00ebsht\u00eb e r\u00ebnd\u00ebsishme testimi i mpreht\u00ebsis\u00eb s\u00eb gjilp\u00ebrave<\/h2>\n\n\n\n<p>Testimi i mpreht\u00ebsis\u00eb s\u00eb gjilp\u00ebrave siguron q\u00eb gjilp\u00ebrat mjek\u00ebsore dhe t\u00eb akupunktur\u00ebs t\u00eb p\u00ebrmbushin specifikimet e k\u00ebrkuara t\u00eb performanc\u00ebs. Gjilp\u00ebrat e mprehura dob\u00ebt mund t\u00eb shkaktojn\u00eb dhimbje, trauma t\u00eb indeve dhe komplikacione. Testimi me cil\u00ebsi t\u00eb lart\u00eb i gjilp\u00ebrave minimizon k\u00ebto rreziqe dhe p\u00ebrmir\u00ebson rezultatet p\u00ebr pacient\u00ebt. Prodhuesit kryesor\u00eb, si <strong data-start=\"1361\" data-end=\"1381\">Instrumentet e qelizave<\/strong>, ofroni makina testimi t\u00eb teknologjis\u00eb m\u00eb t\u00eb fundit q\u00eb i p\u00ebrmbushin standardet nd\u00ebrkomb\u00ebtare.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Standardet kryesore p\u00ebr testimin e mpreht\u00ebsis\u00eb s\u00eb gjilp\u00ebrave<\/h2>\n\n\n\n<p>Kuptimi i standardeve kryesore ndihmon n\u00eb sigurimin e proceseve t\u00eb testimit t\u00eb sakta dhe n\u00eb p\u00ebrputhje me rregulloret. Le t\u00eb eksplorojm\u00eb udh\u00ebzimet m\u00eb t\u00eb r\u00ebnd\u00ebsishme:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><a href=\"https:\/\/www.packqc.com\/sq\/standard\/astm-f3014\/\">ASTM F3014: Testimi i gjilp\u00ebrave kirurgjikale<\/a><\/h3>\n\n\n\n<p>Ky standard, \u201cMetoda standarde e testimit p\u00ebr penetrim t\u00eb gjilp\u00ebrave t\u00eb p\u00ebrdorura n\u00eb qepjet kirurgjikale\u201d, p\u00ebrshkruan procedur\u00ebn p\u00ebr vler\u00ebsimin <strong data-start=\"1890\" data-end=\"1927\">Forca e dep\u00ebrtimit t\u00eb gjilp\u00ebr\u00ebs kirurgjikale<\/strong>. Ai p\u00ebrcakton se si t\u00eb sigurohet gjilp\u00ebra dhe mediumi i testimit dhe si t\u00eb regjistrohen t\u00eb dh\u00ebnat me sakt\u00ebsi (Seksionet 4.1, 4.2, 8.1). Testi p\u00ebrfshin:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Shtr\u00ebngimi i gjilp\u00ebr\u00ebs n\u00eb vendin e duhur p\u00ebr t\u00eb siguruar dep\u00ebrtim t\u00eb nj\u00ebtrajtsh\u00ebm.<\/li>\n\n\n\n<li>Rrotullimi i pajisjes p\u00ebr t\u00eb kaluar gjilp\u00ebr\u00ebn n\u00ebp\u00ebr medium n\u00eb nj\u00eb k\u00ebnd prej 40\u00b0, duke regjistruar vazhdimisht forc\u00ebn e dep\u00ebrtimit.<\/li>\n\n\n\n<li>Monitorimi i gabimeve n\u00eb montim, t\u00eb cilat mund t\u00eb ndikojn\u00eb ndjesh\u00ebm n\u00eb sakt\u00ebsin\u00eb e t\u00eb dh\u00ebnave p\u00ebr forc\u00ebn e penetrimit.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><a href=\"https:\/\/www.packqc.com\/sq\/standard\/iso-7864\/\">ISO 7864: Testimi i gjilp\u00ebrave hipodermike<\/a><\/h3>\n\n\n\n<p><strong data-start=\"3732\" data-end=\"3744\">ISO 7864<\/strong>:2016 p\u00ebrcakton <strong data-start=\"3764\" data-end=\"3820\">k\u00ebrkesat dhe metodat e prov\u00ebs p\u00ebr gjilp\u00ebrat hipodermike<\/strong>. <strong data-start=\"3876\" data-end=\"3887\">Shtojca D<\/strong> p\u00ebrqendrohet n\u00eb matjen e t\u00eb dyjave <strong data-start=\"3918\" data-end=\"3944\">forca maksimale e dep\u00ebrtimit<\/strong> dhe <strong data-start=\"3949\" data-end=\"3963\">forc\u00eb zvarrit\u00ebse<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Gjila dep\u00ebrton nj\u00eb substrat me shpejt\u00ebsi t\u00eb kontrolluar (18\u201328\u00b0C, 25\u201375% lag\u00ebshtia relative).<\/li>\n\n\n\n<li>Profili i forc\u00ebs analizohet p\u00ebr t\u00eb p\u00ebrcaktuar forcat kulmore dhe t\u00eb t\u00ebrheqjes.<\/li>\n\n\n\n<li>T\u00eb dh\u00ebnat nga mostra t\u00eb shumta sigurojn\u00eb rezultate statistikisht t\u00eb q\u00ebndrueshme.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><a href=\"https:\/\/www.packqc.com\/sq\/standard\/iso-17218\/\">ISO 17218: Testimi i gjilp\u00ebrave t\u00eb akupunktur\u00ebs<\/a><\/h3>\n\n\n\n<p>P\u00ebr <strong data-start=\"2485\" data-end=\"2515\">Testimi i gjilp\u00ebrave t\u00eb akupunktur\u00ebs<\/strong>, ISO 17218:2014 (\u201cGjilp\u00ebrat sterile t\u00eb akupunktur\u00ebs p\u00ebr p\u00ebrdorim t\u00eb vet\u00ebm\u201d) ofron procedura p\u00ebr t\u00eb vler\u00ebsuar mpreht\u00ebsin\u00eb e maj\u00ebs dhe intensitetin. Sipas <strong data-start=\"2708\" data-end=\"2719\">Shtojca A<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Mpreht\u00ebsia e maj\u00ebs s\u00eb gjilp\u00ebr\u00ebs matet me forc\u00ebn e nevojshme p\u00ebr t\u00eb dep\u00ebrtuar nj\u00eb <strong data-start=\"2791\" data-end=\"2809\">flet\u00eb alumini<\/strong>.<\/li>\n\n\n\n<li>Intensiteti i maj\u00ebs p\u00ebrcaktohet duke shtypur gjilp\u00ebr\u00ebn mbi nj\u00eb bllok \u00e7eliku, pastaj duke kontrolluar maj\u00ebn p\u00ebr d\u00ebmtim ose deformim.<\/li>\n\n\n\n<li>\u00c7do test siguron q\u00eb gjilp\u00ebra t\u00eb mos p\u00ebrkulet apo t\u00eb mos kapet dhe t\u00eb mos t\u00ebrheq\u00eb fibra kur t\u00ebrhiqet mbi pambuk.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><a href=\"https:\/\/www.packqc.com\/sq\/standard\/iso-11040-4\/\">ISO 11040-4: Testimi i gjilp\u00ebrave t\u00eb shiringave<\/a><\/h3>\n\n\n\n<p><strong data-start=\"3105\" data-end=\"3120\">ISO 11040-4<\/strong> p\u00ebrfshin trupat e shiringave prej qelqi t\u00eb paraplot\u00eb dhe shiringa t\u00eb n\u00ebnmontuara t\u00eb sterilizuara. <strong data-start=\"3255\" data-end=\"3266\">Shtojca F<\/strong> detajon <strong data-start=\"3279\" data-end=\"3306\">Testi i dep\u00ebrtimit me gjilp\u00ebr\u00eb<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Testi p\u00ebrdor nj\u00eb <strong data-start=\"3328\" data-end=\"3381\">makin\u00eb universale p\u00ebr testimin e t\u00ebrheqjes dhe kompresionit<\/strong> (Seksioni F.2.1) me nj\u00eb t\u00eb rekomanduar <strong data-start=\"3417\" data-end=\"3444\">shkalla e kampionimit 500 Hz<\/strong> p\u00ebr sakt\u00ebsin\u00eb maksimale t\u00eb matjes.<\/li>\n\n\n\n<li>Gjila \u00ebsht\u00eb fikse n\u00eb m\u00ebnyr\u00eb t\u00eb drejt\u00ebk\u00ebndshme ndaj <strong data-start=\"3523\" data-end=\"3536\">Flet\u00eb testuese<\/strong> dhe drejtuar me shpejt\u00ebsi t\u00eb kontrolluara (20\u2013200 mm\/min).<\/li>\n\n\n\n<li>Rezultati <strong data-start=\"3604\" data-end=\"3632\">kurba forc\u00eb-zhvendosje<\/strong> p\u00ebrfaq\u00ebson performanc\u00ebn e dep\u00ebrtimit t\u00eb gjilp\u00ebr\u00ebs.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Needle sharpness testing is a critical part of quality assurance for medical, surgical, and acupuncture needles. It directly affects patient comfort, injection precision, and safety. This testing involves evaluating the penetration force of the needle tip and its ability to resist breakage or deformation. Standards such as ASTM F3014, ISO 17218, ISO 11040-4, and ISO [&hellip;]<\/p>","protected":false},"featured_media":0,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"class_list":["post-9290","applications","type-applications","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/sq\/wp-json\/wp\/v2\/applications\/9290","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/sq\/wp-json\/wp\/v2\/applications"}],"about":[{"href":"https:\/\/www.packqc.com\/sq\/wp-json\/wp\/v2\/types\/applications"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/sq\/wp-json\/wp\/v2\/media?parent=9290"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}