{"id":9290,"date":"2026-02-02T11:23:36","date_gmt":"2026-02-02T03:23:36","guid":{"rendered":"https:\/\/www.packqc.com\/applications\/needle-sharpness-testing\/"},"modified":"2026-03-25T11:38:49","modified_gmt":"2026-03-25T03:38:49","slug":"needle-sharpness-testing","status":"publish","type":"applications","link":"https:\/\/www.packqc.com\/sq\/applications\/needle-sharpness-testing\/","title":{"rendered":"Testimi i mpreht\u00ebsis\u00eb s\u00eb gjilp\u00ebr\u00ebs"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Testimi i mpreht\u00ebsis\u00eb s\u00eb gjilp\u00ebrave \u00ebsht\u00eb nj\u00eb pjes\u00eb kritike e sigurimit t\u00eb cil\u00ebsis\u00eb p\u00ebr gjilp\u00ebrat mjek\u00ebsore, kirurgjikale dhe t\u00eb akupunktur\u00ebs. Ai ndikon drejtp\u00ebrdrejt n\u00eb rehati t\u00eb pacientit, sakt\u00ebsin\u00eb e injeksionit dhe sigurin\u00eb. Ky testim p\u00ebrfshin vler\u00ebsimin e <strong data-start=\"763\" data-end=\"784\">forc\u00eb dep\u00ebrtuese<\/strong> t\u00eb maj\u00ebs s\u00eb gjilp\u00ebr\u00ebs dhe aft\u00ebsis\u00eb s\u00eb saj p\u00ebr t'u rezistuar thyerjes ose deformimit. Standarde t\u00eb tilla si <strong data-start=\"872\" data-end=\"886\">ASTM F3014<\/strong>, <strong data-start=\"888\" data-end=\"901\">ISO 17218<\/strong>, <strong data-start=\"903\" data-end=\"918\">ISO 11040-4<\/strong>, dhe <strong data-start=\"924\" data-end=\"936\">ISO 7864<\/strong> ofroni metoda rigoroze testimi p\u00ebr t\u00eb siguruar rezultate t\u00eb besueshme dhe t\u00eb riprodhueshme.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pse \u00ebsht\u00eb e r\u00ebnd\u00ebsishme testimi i mpreht\u00ebsis\u00eb s\u00eb gjilp\u00ebrave<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Testimi i mpreht\u00ebsis\u00eb s\u00eb gjilp\u00ebrave siguron q\u00eb gjilp\u00ebrat mjek\u00ebsore dhe t\u00eb akupunktur\u00ebs t\u00eb p\u00ebrmbushin specifikimet e k\u00ebrkuara t\u00eb performanc\u00ebs. Gjilp\u00ebrat e mprehura dob\u00ebt mund t\u00eb shkaktojn\u00eb dhimbje, trauma t\u00eb indeve dhe komplikacione. Testimi me cil\u00ebsi t\u00eb lart\u00eb i gjilp\u00ebrave minimizon k\u00ebto rreziqe dhe p\u00ebrmir\u00ebson rezultatet p\u00ebr pacient\u00ebt. Prodhuesit kryesor\u00eb, si <strong data-start=\"1361\" data-end=\"1381\">Instrumentet e qelizave<\/strong>, ofroni makina testimi t\u00eb teknologjis\u00eb m\u00eb t\u00eb fundit q\u00eb i p\u00ebrmbushin standardet nd\u00ebrkomb\u00ebtare.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Standardet kryesore p\u00ebr testimin e mpreht\u00ebsis\u00eb s\u00eb gjilp\u00ebrave<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Kuptimi i standardeve kryesore ndihmon n\u00eb sigurimin e proceseve t\u00eb testimit t\u00eb sakta dhe n\u00eb p\u00ebrputhje me rregulloret. Le t\u00eb eksplorojm\u00eb udh\u00ebzimet m\u00eb t\u00eb r\u00ebnd\u00ebsishme:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><a href=\"https:\/\/www.packqc.com\/sq\/standard\/astm-f3014\/\">ASTM F3014: Testimi i gjilp\u00ebrave kirurgjikale<\/a><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ky standard, \u201cMetoda standarde e testimit p\u00ebr penetrim t\u00eb gjilp\u00ebrave t\u00eb p\u00ebrdorura n\u00eb qepjet kirurgjikale\u201d, p\u00ebrshkruan procedur\u00ebn p\u00ebr vler\u00ebsimin <strong data-start=\"1890\" data-end=\"1927\">Forca e dep\u00ebrtimit t\u00eb gjilp\u00ebr\u00ebs kirurgjikale<\/strong>. Ai p\u00ebrcakton se si t\u00eb sigurohet gjilp\u00ebra dhe mediumi i testimit dhe si t\u00eb regjistrohen t\u00eb dh\u00ebnat me sakt\u00ebsi (Seksionet 4.1, 4.2, 8.1). Testi p\u00ebrfshin:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Shtr\u00ebngimi i gjilp\u00ebr\u00ebs n\u00eb vendin e duhur p\u00ebr t\u00eb siguruar dep\u00ebrtim t\u00eb nj\u00ebtrajtsh\u00ebm.<\/li>\n\n\n\n<li>Rrotullimi i pajisjes p\u00ebr t\u00eb kaluar gjilp\u00ebr\u00ebn n\u00ebp\u00ebr medium n\u00eb nj\u00eb k\u00ebnd prej 40\u00b0, duke regjistruar vazhdimisht forc\u00ebn e dep\u00ebrtimit.<\/li>\n\n\n\n<li>Monitorimi i gabimeve n\u00eb montim, t\u00eb cilat mund t\u00eb ndikojn\u00eb ndjesh\u00ebm n\u00eb sakt\u00ebsin\u00eb e t\u00eb dh\u00ebnave p\u00ebr forc\u00ebn e penetrimit.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><a href=\"https:\/\/www.packqc.com\/sq\/standard\/iso-7864\/\">ISO 7864: Testimi i gjilp\u00ebrave hipodermike<\/a><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong data-start=\"3732\" data-end=\"3744\">ISO 7864<\/strong>:2016 p\u00ebrcakton <strong data-start=\"3764\" data-end=\"3820\">k\u00ebrkesat dhe metodat e prov\u00ebs p\u00ebr gjilp\u00ebrat hipodermike<\/strong>. <strong data-start=\"3876\" data-end=\"3887\">Shtojca D<\/strong> p\u00ebrqendrohet n\u00eb matjen e t\u00eb dyjave <strong data-start=\"3918\" data-end=\"3944\">forca maksimale e dep\u00ebrtimit<\/strong> dhe <strong data-start=\"3949\" data-end=\"3963\">forc\u00eb zvarrit\u00ebse<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Gjila dep\u00ebrton nj\u00eb substrat me shpejt\u00ebsi t\u00eb kontrolluar (18\u201328\u00b0C, 25\u201375% lag\u00ebshtia relative).<\/li>\n\n\n\n<li>Profili i forc\u00ebs analizohet p\u00ebr t\u00eb p\u00ebrcaktuar forcat kulmore dhe t\u00eb t\u00ebrheqjes.<\/li>\n\n\n\n<li>T\u00eb dh\u00ebnat nga mostra t\u00eb shumta sigurojn\u00eb rezultate statistikisht t\u00eb q\u00ebndrueshme.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><a href=\"https:\/\/www.packqc.com\/sq\/standard\/iso-17218\/\">ISO 17218: Testimi i gjilp\u00ebrave t\u00eb akupunktur\u00ebs<\/a><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">P\u00ebr <strong data-start=\"2485\" data-end=\"2515\">Testimi i gjilp\u00ebrave t\u00eb akupunktur\u00ebs<\/strong>, ISO 17218:2014 (\u201cGjilp\u00ebrat sterile t\u00eb akupunktur\u00ebs p\u00ebr p\u00ebrdorim t\u00eb vet\u00ebm\u201d) ofron procedura p\u00ebr t\u00eb vler\u00ebsuar mpreht\u00ebsin\u00eb e maj\u00ebs dhe intensitetin. Sipas <strong data-start=\"2708\" data-end=\"2719\">Shtojca A<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Mpreht\u00ebsia e maj\u00ebs s\u00eb gjilp\u00ebr\u00ebs matet me forc\u00ebn e nevojshme p\u00ebr t\u00eb dep\u00ebrtuar nj\u00eb <strong data-start=\"2791\" data-end=\"2809\">flet\u00eb alumini<\/strong>.<\/li>\n\n\n\n<li>Intensiteti i maj\u00ebs p\u00ebrcaktohet duke shtypur gjilp\u00ebr\u00ebn mbi nj\u00eb bllok \u00e7eliku, pastaj duke kontrolluar maj\u00ebn p\u00ebr d\u00ebmtim ose deformim.<\/li>\n\n\n\n<li>\u00c7do test siguron q\u00eb gjilp\u00ebra t\u00eb mos p\u00ebrkulet apo t\u00eb mos kapet dhe t\u00eb mos t\u00ebrheq\u00eb fibra kur t\u00ebrhiqet mbi pambuk.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><a href=\"https:\/\/www.packqc.com\/sq\/standard\/iso-11040-4\/\">ISO 11040-4: Testimi i gjilp\u00ebrave t\u00eb shiringave<\/a><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong data-start=\"3105\" data-end=\"3120\">ISO 11040-4<\/strong> p\u00ebrfshin trupat e shiringave prej qelqi t\u00eb paraplot\u00eb dhe shiringa t\u00eb n\u00ebnmontuara t\u00eb sterilizuara. <strong data-start=\"3255\" data-end=\"3266\">Shtojca F<\/strong> detajon <strong data-start=\"3279\" data-end=\"3306\">Testi i dep\u00ebrtimit me gjilp\u00ebr\u00eb<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Testi p\u00ebrdor nj\u00eb <strong data-start=\"3328\" data-end=\"3381\">makin\u00eb universale p\u00ebr testimin e t\u00ebrheqjes dhe kompresionit<\/strong> (Seksioni F.2.1) me nj\u00eb t\u00eb rekomanduar <strong data-start=\"3417\" data-end=\"3444\">shkalla e kampionimit 500 Hz<\/strong> p\u00ebr sakt\u00ebsin\u00eb maksimale t\u00eb matjes.<\/li>\n\n\n\n<li>Gjila \u00ebsht\u00eb fikse n\u00eb m\u00ebnyr\u00eb t\u00eb drejt\u00ebk\u00ebndshme ndaj <strong data-start=\"3523\" data-end=\"3536\">Flet\u00eb testuese<\/strong> dhe drejtuar me shpejt\u00ebsi t\u00eb kontrolluara (20\u2013200 mm\/min).<\/li>\n\n\n\n<li>Rezultati <strong data-start=\"3604\" data-end=\"3632\">kurba forc\u00eb-zhvendosje<\/strong> p\u00ebrfaq\u00ebson performanc\u00ebn e dep\u00ebrtimit t\u00eb gjilp\u00ebr\u00ebs.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Testimi i mpreht\u00ebsis\u00eb s\u00eb gjilp\u00ebrave \u00ebsht\u00eb nj\u00eb pjes\u00eb kritike e sigurimit t\u00eb cil\u00ebsis\u00eb p\u00ebr gjilp\u00ebrat mjek\u00ebsore, kirurgjikale dhe t\u00eb akupunktur\u00ebs. Ai ndikon drejtp\u00ebrdrejt n\u00eb rehati t\u00eb pacientit, sakt\u00ebsin\u00eb e injektimit dhe sigurin\u00eb. Ky testim p\u00ebrfshin vler\u00ebsimin e forc\u00ebs s\u00eb dep\u00ebrtimit t\u00eb maj\u00ebs s\u00eb gjilp\u00ebr\u00ebs dhe aft\u00ebsin\u00eb e saj p\u00ebr t'u rezistuar thyerjes ose deformimit. Standardet si ASTM F3014, ISO 17218, ISO 11040-4 dhe ISO [\u2026]<\/p>","protected":false},"featured_media":0,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"class_list":["post-9290","applications","type-applications","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/sq\/wp-json\/wp\/v2\/applications\/9290","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/sq\/wp-json\/wp\/v2\/applications"}],"about":[{"href":"https:\/\/www.packqc.com\/sq\/wp-json\/wp\/v2\/types\/applications"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/sq\/wp-json\/wp\/v2\/media?parent=9290"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}