{"id":9545,"date":"2026-02-02T14:53:11","date_gmt":"2026-02-02T06:53:11","guid":{"rendered":"https:\/\/www.packqc.com\/products\/bst-01-glass-ampoule-break-force-tester\/"},"modified":"2026-04-20T16:45:00","modified_gmt":"2026-04-20T08:45:00","slug":"bst-01-glass-ampoule-break-force-tester","status":"publish","type":"products","link":"https:\/\/www.packqc.com\/sq\/products\/bst-01-glass-ampoule-break-force-tester\/","title":{"rendered":"Testues i forc\u00ebs s\u00eb thyerjes s\u00eb ampul\u00ebs BST-01"},"content":{"rendered":"<h2 class=\"wp-block-heading\">I. Prezantimi i testuesit t\u00eb forc\u00ebs s\u00eb thyerjes s\u00eb ampul\u00ebs s\u00eb qelqit<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">1. P\u00ebrkufizimi dhe funksioni primar<\/h3>\n\n\n\n<p>Testuesi i forc\u00ebs s\u00eb thyerjes s\u00eb ampul\u00ebs s\u00eb qelqit \u00ebsht\u00eb nj\u00eb instrument i avancuar i krijuar p\u00ebr t\u00eb matur forc\u00ebn e nevojshme p\u00ebr t\u00eb thyer ampulat e xhamit. Ky test kritik siguron integritetin dhe sigurin\u00eb e paketimit farmaceutik, duke garantuar q\u00eb ampulat mund t\u00eb hapen me leht\u00ebsi dhe q\u00ebndrueshm\u00ebri pa kompromentuar p\u00ebrmbajtjen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2. R\u00ebnd\u00ebsia n\u00eb Industri<\/h3>\n\n\n\n<p>N\u00eb industrin\u00eb farmaceutike dhe t\u00eb pajisjeve mjek\u00ebsore, cil\u00ebsia dhe besueshm\u00ebria e paketimit jan\u00eb par\u00ebsore. Ampulat e qelqit p\u00ebrdoren gjer\u00ebsisht p\u00ebr pap\u00ebrshkueshm\u00ebrin\u00eb dhe inertitetin e tyre, t\u00eb cilat mbrojn\u00eb p\u00ebrmbajtjen nga ndotja. Testuesi i forc\u00ebs s\u00eb thyerjes siguron q\u00eb k\u00ebto ampula t\u00eb p\u00ebrmbushin standardet strikte t\u00eb siguris\u00eb dhe p\u00ebrdorshm\u00ebris\u00eb, duke parandaluar k\u00ebshtu probleme t\u00eb tilla si derdhja, kontaminimi dhe d\u00ebmtimi i p\u00ebrdoruesit.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3. P\u00ebrfitimet dhe ve\u00e7orit\u00eb kryesore<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Testimi i sakt\u00ebsis\u00eb<\/strong>: Matja e sakt\u00eb e forc\u00ebs s\u00eb nevojshme p\u00ebr t\u00eb thyer ampulat e qelqit.<\/li>\n\n\n\n<li><strong>Pajtueshm\u00ebria me Standardet<\/strong>: Siguron respektimin e k\u00ebrkesave t\u00eb ISO 9187, duke ofruar besim n\u00eb cil\u00ebsin\u00eb dhe sigurin\u00eb e paketimit.<\/li>\n\n\n\n<li><strong>Nd\u00ebrfaqe miq\u00ebsore p\u00ebr p\u00ebrdoruesit<\/strong>: Funksionim i leht\u00eb me nj\u00eb nd\u00ebrfaqe t\u00eb ekranit me prekje.<\/li>\n\n\n\n<li><strong>Karakteristikat e Siguris\u00eb<\/strong>: P\u00ebrfshin mbulesa mbrojt\u00ebse dhe tuba grumbullimi t\u00eb mostrave p\u00ebr t\u00eb siguruar procedura t\u00eb sigurta testimi.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">4. Aplikacionet<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Industria Farmaceutike<\/strong>: Siguron integritetin dhe sigurin\u00eb e paketimit t\u00eb drog\u00ebs.<\/li>\n\n\n\n<li><strong>Prodhimi i pajisjeve mjek\u00ebsore<\/strong>: Vler\u00ebson cil\u00ebsin\u00eb e materialeve t\u00eb paketimit t\u00eb p\u00ebrdorura n\u00eb pajisjet mjek\u00ebsore.<\/li>\n\n\n\n<li><strong>Agjencit\u00eb e Inspektimit t\u00eb Cil\u00ebsis\u00eb<\/strong>: Ofron t\u00eb dh\u00ebna t\u00eb besueshme p\u00ebr pajtueshm\u00ebrin\u00eb rregullatore dhe sigurimin e cil\u00ebsis\u00eb.<\/li>\n\n\n\n<li><strong>K\u00ebrkim dhe Zhvillim<\/strong>: Ndihmon n\u00eb zhvillimin e zgjidhjeve dhe materialeve t\u00eb reja t\u00eb paketimit.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">II. Karakteristikat dhe Specifikimet kryesore<\/h2>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/www.packqc.com\/wp-content\/uploads\/elementor\/thumbs\/ISO-9187-Glass-Ampoule-Break-Force-Tester-2-qq7ite79k6uv85n9s3369rsi1mk93bpm2e36hbuzuo.jpg\" alt=\"Testues i forc\u00ebs s\u00eb thyerjes s\u00eb ampul\u00ebs s\u00eb xhamit ISO 9187 2\" title=\"Testues i forc\u00ebs s\u00eb thyerjes s\u00eb ampul\u00ebs s\u00eb xhamit ISO 9187 2\"\/><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">1. Karakteristikat teknike<\/h3>\n\n\n\n<p>Testuesi i forc\u00ebs s\u00eb thyerjes s\u00eb ampul\u00ebs s\u00eb qelqit \u00ebsht\u00eb i pajisur me ve\u00e7ori t\u00eb avancuara q\u00eb e b\u00ebjn\u00eb at\u00eb nj\u00eb mjet thelb\u00ebsor n\u00eb testimin e materialeve:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Nj\u00ebsia e kontrollit PLC<\/strong>: P\u00ebr kontroll t\u00eb sakt\u00eb dhe t\u00eb besuesh\u00ebm t\u00eb procesit t\u00eb testimit.<\/li>\n\n\n\n<li><strong>Ekran me prekje HMI<\/strong>: Thjesht\u00ebson nd\u00ebrveprimin e p\u00ebrdoruesit dhe futjen e t\u00eb dh\u00ebnave.<\/li>\n\n\n\n<li><strong>Motor stepper me vidhos me top precize<\/strong>: Siguron kontroll t\u00eb sakt\u00eb t\u00eb shpejt\u00ebsis\u00eb dhe kushte t\u00eb q\u00ebndrueshme testimi.<\/li>\n\n\n\n<li><strong>Karakteristikat e Siguris\u00eb<\/strong>: P\u00ebrfshin nj\u00eb tub grumbullimi t\u00eb mostrave p\u00ebr mostrat e thyera dhe nj\u00eb mbules\u00eb mbrojt\u00ebse p\u00ebr pjes\u00ebt e gabuara.<\/li>\n\n\n\n<li><strong>Pajisjet e shum\u00ebfishta t\u00eb prov\u00ebs<\/strong>: E disponueshme n\u00eb kapacitete 1ml, 2ml, 5ml, 10ml dhe 20ml, duke u p\u00ebrshtatur me specifika t\u00eb ndryshme.<\/li>\n\n\n\n<li><strong>Testimi i gjithansh\u00ebm<\/strong>: Mb\u00ebshtet testimin e materialeve t\u00eb ndryshme t\u00eb p\u00ebrdorura n\u00eb paketimin mjek\u00ebsor.<\/li>\n\n\n\n<li><strong>Pajisja kufizuese dhe kthimi automatik<\/strong>: Rrit sigurin\u00eb dhe efikasitetin operacional.<\/li>\n\n\n\n<li><strong>Shpejt\u00ebsia e rregullueshme e prov\u00ebs<\/strong>: I personalizuesh\u00ebm p\u00ebr t\u00eb p\u00ebrmbushur k\u00ebrkesat e ndryshme t\u00eb testimit.<\/li>\n\n\n\n<li><strong>Mikroprinter me matric\u00eb me pika<\/strong>: Leht\u00ebson printimin e leht\u00eb t\u00eb rezultateve t\u00eb prov\u00ebs.<\/li>\n\n\n\n<li><strong>RS 232 Lidhshm\u00ebria dhe Softueri<\/strong>: Karakteristika opsionale p\u00ebr menaxhimin dhe analiz\u00ebn e p\u00ebrmir\u00ebsuar t\u00eb t\u00eb dh\u00ebnave.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">2. Specifikimet teknike<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Gama e testimit<\/td><td>0 ~ 200 N (Ose sipas nevoj\u00ebs)<\/td><\/tr><tr><td>Shpejt\u00ebsia<\/td><td>1~500 mm\/min<\/td><\/tr><tr><td>Rezolucioni<\/td><td>0,1 N<\/td><\/tr><tr><td>Sakt\u00ebsia<\/td><td>0,5% FS<\/td><\/tr><tr><td>Fuqia<\/td><td>110~ 220V 50\/60Hz<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">III. Metodat e Testimit<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">1. Hyrje n\u00eb Metodat e Testimit<\/h3>\n\n\n\n<p>Testimi i q\u00ebndruesh\u00ebm dhe i sakt\u00eb i ampulave t\u00eb qelqit \u00ebsht\u00eb thelb\u00ebsor p\u00ebr t\u00eb garantuar sigurin\u00eb dhe pajtueshm\u00ebrin\u00eb e produktit. Testi i forc\u00ebs s\u00eb thyerjes \u00ebsht\u00eb nj\u00eb metod\u00eb e standardizuar q\u00eb p\u00ebrdoret p\u00ebr t\u00eb matur forc\u00ebn e nevojshme p\u00ebr hapjen e ampulave t\u00eb xhamit, duke siguruar q\u00eb ato t\u00eb p\u00ebrmbushin standardet e industris\u00eb dhe rregullatore.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2. Procedura e testimit hap pas hapi<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>P\u00ebrgatitja e mostr\u00ebs<\/strong>: Pastroni dhe inspektoni ampul\u00ebn p\u00ebr t&#039;u siguruar q\u00eb nuk ka defekte.<\/li>\n\n\n\n<li><strong>Vendosja e testuesit<\/strong>: Instaloni pajisjen e duhur t\u00eb testimit dhe sigurojeni ampul\u00ebn n\u00eb vend.<\/li>\n\n\n\n<li><strong>Ekzekutimi i Testit t\u00eb Forc\u00ebs Break<\/strong>: Filloni testin duke p\u00ebrdorur nd\u00ebrfaqen e ekranit me prekje. Makina ushtron forc\u00eb derisa ampula t\u00eb prishet.<\/li>\n\n\n\n<li><strong>Regjistrimi dhe analizimi i rezultateve<\/strong>: Testuesi regjistron forc\u00ebn e thyerjes, e cila mund t\u00eb printohet ose transferohet n\u00eb softuer p\u00ebr analiza t\u00eb m\u00ebtejshme.<\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"Testues i forc\u00ebs s\u00eb thyerjes s\u00eb ampulave BST-01\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/TDjSGibmf2o?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">IV. Standardet ISO 9187<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">1. P\u00ebrmbledhje e ISO 9187<\/h3>\n\n\n\n<p><a href=\"https:\/\/www.iso.org\/standard\/55920.html\" target=\"_blank\" rel=\"noopener nofollow\">ISO 9187<\/a> specifikon k\u00ebrkesat dhe metodat e prov\u00ebs p\u00ebr ampulat e qelqit t\u00eb p\u00ebrdorura n\u00eb industrin\u00eb farmaceutike. Siguron q\u00eb ampulat jan\u00eb t\u00eb lehta p\u00ebr t&#039;u hapur, ofrojn\u00eb mbrojtje adekuate p\u00ebr p\u00ebrmbajtjen e tyre dhe jan\u00eb t\u00eb sigurta p\u00ebr t&#039;u trajtuar.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2. P\u00ebrmbajtja e ISO 9187<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>K\u00ebrkesat p\u00ebr ampula xhami<\/strong>: P\u00ebrcakton dimensionet, vetit\u00eb e materialit dhe cil\u00ebsin\u00eb e prodhimit.<\/li>\n\n\n\n<li><strong>Specifikimet p\u00ebr testimin e forc\u00ebs s\u00eb thyerjes<\/strong>: Detajon metodat p\u00ebr matjen e forc\u00ebs s\u00eb nevojshme p\u00ebr hapjen e ampulave.<\/li>\n\n\n\n<li><strong>Kufijt\u00eb dhe kriteret e pranueshme p\u00ebr kalim\/d\u00ebshtim<\/strong>: P\u00ebrcakton gam\u00ebn e pranueshme t\u00eb forcave t\u00eb thyerjes p\u00ebr t\u00eb garantuar sigurin\u00eb dhe p\u00ebrdorshm\u00ebrin\u00eb.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">3. Pajtueshm\u00ebria me ISO 9187<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Sigurimi i Pajtueshm\u00ebris\u00eb<\/strong>: Testuesi i forc\u00ebs s\u00eb thyerjes s\u00eb ampul\u00ebs s\u00eb xhamit \u00ebsht\u00eb projektuar p\u00ebr t\u00eb p\u00ebrmbushur standardet ISO 9187, duke ofruar rezultate t\u00eb besueshme dhe t\u00eb sakta testimi.<\/li>\n\n\n\n<li><strong>P\u00ebrfitimet e respektimit t\u00eb standardeve ISO<\/strong>: Siguron sigurin\u00eb e produktit, rrit besimin e konsumator\u00ebve dhe plot\u00ebson k\u00ebrkesat rregullatore.<\/li>\n\n\n\n<li><strong>Raste studimore ose shembuj t\u00eb p\u00ebrputhshm\u00ebris\u00eb<\/strong>: Demonstron aplikacione n\u00eb bot\u00ebn reale ku respektimi i ISO 9187 ka siguruar cil\u00ebsin\u00eb dhe sigurin\u00eb e produktit.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">V. P\u00ebrshtatje<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">K\u00ebrkesat e ve\u00e7anta t\u00eb testimit<\/h3>\n\n\n\n<p>Testuesi i forc\u00ebs s\u00eb thyerjes s\u00eb ampul\u00ebs s\u00eb xhamit mund t\u00eb personalizohet p\u00ebr t\u00eb p\u00ebrmbushur nevojat specifike t\u00eb testimit. Parametrat dhe konfigurimet e personalizueshme t\u00eb testit sigurojn\u00eb q\u00eb k\u00ebrkesat unike p\u00ebr lloje t\u00eb ndryshme ampulash xhami dhe materialesh paketimi mund t\u00eb testohen me sakt\u00ebsi.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">VI. FAQ<\/h2>\n\n\n\n<p><a tabindex=\"0\">1. Cili \u00ebsht\u00eb funksioni kryesor i testuesit t\u00eb forc\u00ebs s\u00eb thyerjes s\u00eb ampul\u00ebs s\u00eb xhamit?<\/a><\/p>\n\n\n\n<p>Funksioni kryesor \u00ebsht\u00eb matja e forc\u00ebs s\u00eb nevojshme p\u00ebr t\u00eb thyer ampulat e qelqit, duke u siguruar q\u00eb ato t\u00eb p\u00ebrmbushin standardet e siguris\u00eb dhe t\u00eb p\u00ebrdorshm\u00ebris\u00eb.<\/p>\n\n\n\n<p><a tabindex=\"0\">2. Si p\u00ebrputhet testuesi i forc\u00ebs s\u00eb thyerjes s\u00eb ampul\u00ebs s\u00eb xhamit me ISO 9187?<\/a><\/p>\n\n\n\n<p>Testuesi \u00ebsht\u00eb projektuar p\u00ebr t&#039;iu p\u00ebrmbajtur specifikimeve dhe k\u00ebrkesave t\u00eb p\u00ebrshkruara n\u00eb ISO 9187, duke siguruar rezultate t\u00eb q\u00ebndrueshme dhe t\u00eb besueshme t\u00eb testimit.<\/p>\n\n\n\n<p><a tabindex=\"0\">3. Cilat jan\u00eb p\u00ebrfitimet kryesore t\u00eb p\u00ebrdorimit t\u00eb k\u00ebtij testuesi n\u00eb industrin\u00eb farmaceutike?<\/a><\/p>\n\n\n\n<p>Siguron integritetin dhe sigurin\u00eb e paketimit farmaceutik, zvog\u00eblon rrezikun e kontaminimit dhe rrit pajtueshm\u00ebrin\u00eb me standardet rregullatore.<\/p>\n\n\n\n<p><a tabindex=\"0\">4. A mund t\u00eb personalizohet testuesi p\u00ebr lloje t\u00eb ndryshme ampulash?<\/a><\/p>\n\n\n\n<p>Po, ai ofron parametra testimi dhe pajisje t\u00eb personalizueshme p\u00ebr t\u00eb akomoduar madh\u00ebsi dhe specifikime t\u00eb ndryshme t\u00eb ampulave.<\/p>\n\n\n\n<p><a tabindex=\"0\">5. Cilat ve\u00e7ori sigurie p\u00ebrfshihen n\u00eb testuesin e forc\u00ebs s\u00eb thyerjes s\u00eb ampul\u00ebs s\u00eb xhamit?<\/a><\/p>\n\n\n\n<p>Ve\u00e7orit\u00eb e siguris\u00eb p\u00ebrfshijn\u00eb nj\u00eb mbules\u00eb mbrojt\u00ebse p\u00ebr pjes\u00ebt e gabuara, nj\u00eb tub grumbullimi t\u00eb mostrave p\u00ebr mostrat e thyera dhe nj\u00eb pajisje kufizuese p\u00ebr siguri t\u00eb shtuar operacionale.<\/p>","protected":false},"excerpt":{"rendered":"<p>Testuesi i forc\u00ebs p\u00ebr thyerjen e ampulave prej qelqi \u00ebsht\u00eb nj\u00eb instrument i avancuar i projektuar p\u00ebr t\u00eb matur forc\u00ebn e nevojshme p\u00ebr t'i thyer ampulat prej qelqi.<\/p>","protected":false},"featured_media":4898,"parent":0,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"product-category":[618,434,493,438,494],"product-tag":[],"class_list":["post-9545","products","type-products","status-publish","has-post-thumbnail","hentry","product-category-glass-ampoule-testing","product-category-iso","product-category-iso-9187","product-category-medical-and-pharmaceutical-testing","product-category-tensile-tester"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/sq\/wp-json\/wp\/v2\/products\/9545","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/sq\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.packqc.com\/sq\/wp-json\/wp\/v2\/types\/products"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/sq\/wp-json\/wp\/v2\/media\/4898"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/sq\/wp-json\/wp\/v2\/media?parent=9545"}],"wp:term":[{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/www.packqc.com\/sq\/wp-json\/wp\/v2\/product-category?post=9545"},{"taxonomy":"product-tag","embeddable":true,"href":"https:\/\/www.packqc.com\/sq\/wp-json\/wp\/v2\/product-tag?post=9545"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}