{"id":9834,"date":"2026-02-24T15:11:44","date_gmt":"2026-02-24T07:11:44","guid":{"rendered":"https:\/\/www.packqc.com\/standard\/iso-719-2\/"},"modified":"2026-04-16T09:54:21","modified_gmt":"2026-04-16T01:54:21","slug":"iso-719","status":"publish","type":"standard","link":"https:\/\/www.packqc.com\/sq\/standard\/iso-719\/","title":{"rendered":"ISO 719"},"content":{"rendered":"<h2 class=\"wp-block-heading\">\u00c7far\u00eb \u00ebsht\u00eb ISO 719?<\/h2>\n\n\n\n<p><strong data-start=\"1071\" data-end=\"1087\">ISO 719:2020<\/strong> \u00ebsht\u00eb standardi nd\u00ebrkomb\u00ebtar me titullin <em data-start=\"1125\" data-end=\"1220\">\u201cQelqi \u2014 Rezistenca hidrolytike e grimcave t\u00eb qelqit n\u00eb 98 \u00b0C \u2014 Metoda e prov\u00ebs dhe klasifikimi.\u201d<\/em> Kjo p\u00ebrcakton nj\u00eb procedur\u00eb p\u00ebr testimin e rezistenc\u00ebs s\u00eb grimcave t\u00eb qelqit ndaj ujit n\u00eb temperatura t\u00eb larta. Testi mat v\u00ebllimin e acidit t\u00eb nevojsh\u00ebm p\u00ebr t\u00eb neutralizuar alkalin e nxjerr\u00eb nga nj\u00eb mas\u00eb e caktuar qelqi. Rezultatet mund t\u00eb raportohen ose si v\u00ebllim acidi ose si p\u00ebrmbajtje ekuivalente e oksidit t\u00eb natriumit, duke ofruar nj\u00eb baz\u00eb t\u00eb matshme p\u00ebr klasifikim.<\/p>\n\n\n\n<p>Ky standard \u00ebsht\u00eb ve\u00e7an\u00ebrisht i dizajnuar p\u00ebr <strong data-start=\"1605\" data-end=\"1635\">llojet e xhamit m\u00eb pak rezistente<\/strong>, si p.sh. <strong data-start=\"1645\" data-end=\"1664\">xham soda-g\u00eblqeror<\/strong>, ndryshe nga <strong data-start=\"1673\" data-end=\"1684\">ISO 720<\/strong>, i cili synon xhamat borosilikat dhe t\u00eb tjer\u00eb m\u00eb t\u00eb q\u00ebndruesh\u00ebm kimikisht.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Testi i rezistenc\u00ebs hidrolitike p\u00ebr xhamin: Pse ka r\u00ebnd\u00ebsi<\/h2>\n\n\n\n<p>T\u00eb <strong data-start=\"1824\" data-end=\"1864\">Test hidrolik i rezistenc\u00ebs p\u00ebr xham<\/strong> p\u00ebrcakton sa material alkalin shkrin n\u00eb uj\u00eb kur qelqi ekspozohet ndaj temperaturave t\u00eb larta. K\u00ebto t\u00eb dh\u00ebna jan\u00eb thelb\u00ebsore p\u00ebr:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Sigurimi i stabilitetit kimik t\u00eb <strong data-start=\"2032\" data-end=\"2061\">kontejner\u00eb farmaceutik\u00eb<\/strong> si ampula, fiale dhe shishe orale.<\/li>\n\n\n\n<li>Parandalimi i degradimit t\u00eb produktit t\u00eb shkaktuar nga nd\u00ebrveprimi midis paketimit dhe medikamentit.<\/li>\n\n\n\n<li>Klasifikimi i llojeve t\u00eb qelqit bazuar n\u00eb q\u00ebndrueshm\u00ebri dhe zgjedhja e materialeve t\u00eb p\u00ebrshtatshme t\u00eb paketimit.<\/li>\n<\/ul>\n\n\n\n<p>Nj\u00eb vler\u00ebsim i dob\u00ebt i rezistenc\u00ebs hidrolitike mund t\u00eb tregoj\u00eb nj\u00eb rrezik p\u00ebr larje t\u00eb alkalive, gj\u00eb q\u00eb mund t\u00eb kompromentoj\u00eb jet\u00ebgjat\u00ebsin\u00eb ose sigurin\u00eb e p\u00ebrmbajtjes.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Procedura e testimit t\u00eb grimcave t\u00eb qelqit bazuar n\u00eb ISO 719<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">P\u00ebrgatitja e mostr\u00ebs<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"2601\" data-end=\"2613\">Shkat\u00ebrrim<\/strong>Artikujt prej xhami (t\u00ebrhequr) th\u00ebrrmohen manualisht ose mekanikisht n\u00eb grimca.<\/li>\n\n\n\n<li><strong data-start=\"2693\" data-end=\"2704\">Sit\u00eb<\/strong>Grumbujt ndahen duke p\u00ebrdorur sit\u00eb me madh\u00ebsi 710 \u00b5m, 500 \u00b5m dhe 300 \u00b5m. P\u00ebrdoren vet\u00ebm grumbujt q\u00eb kalojn\u00eb sit\u00ebn 500 \u00b5m, por q\u00eb mbahen n\u00eb sit\u00ebn 300 \u00b5m.<\/li>\n\n\n\n<li><strong data-start=\"2841\" data-end=\"2853\">Pastrim<\/strong>Grumbujt lahen me aceton\u00eb dhe pastrohen n\u00eb nj\u00eb banj\u00eb ultrasonike. M\u00eb pas thahet n\u00eb 140\u00b0C.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Procedura e testimit<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"2978\" data-end=\"2990\">Peshimi<\/strong>2 g kokrra t\u00eb pastra e t\u00eb thata peshohen n\u00eb secil\u00ebn nga tre kolba volumetrike.<\/li>\n\n\n\n<li><strong data-start=\"3069\" data-end=\"3083\">Nxjerrje<\/strong>Flask\u00ebt jan\u00eb mbushur me uj\u00eb t\u00eb klas\u00ebs 2 dhe ngrohen n\u00eb nj\u00eb banj\u00eb me uj\u00eb n\u00eb 98\u00b0C p\u00ebr 60 minuta.<\/li>\n\n\n\n<li><strong data-start=\"3173\" data-end=\"3186\">Titrim<\/strong>Pas ftohjes, nj\u00eb pjes\u00eb e l\u00ebngut sip\u00ebrfaq\u00ebsor titrohet duke p\u00ebrdorur metil t\u00eb kuq si tregues p\u00ebr t\u00eb p\u00ebrcaktuar sasin\u00eb e alkalit t\u00eb \u00e7liruar.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Klasifikimi<\/h3>\n\n\n\n<p>N\u00eb baz\u00eb t\u00eb v\u00ebllimit t\u00eb titrantit t\u00eb p\u00ebrdorur, gota klasifikohet n\u00eb klasa rezistence hidrolytike. V\u00ebllimet m\u00eb t\u00eb larta tregojn\u00eb \u00e7lirim m\u00eb t\u00eb madh t\u00eb alkalineve, duke sugjeruar rezistenc\u00eb m\u00eb t\u00eb ul\u00ebt hidrolytike.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Instrumenti n\u00eb qend\u00ebr t\u00eb v\u00ebmendjes: GHR-01A nga Cell Instruments<\/h2>\n\n\n\n<p>P\u00ebr t\u00eb thjeshtuar <a href=\"https:\/\/www.iso.org\/standard\/77843.html\" target=\"_blank\" rel=\"noopener nofollow\">ISO 719<\/a> p\u00ebr procesin e testimit dhe reduktimin e ngarkes\u00ebs manuale, Cell Instruments ofron <strong data-start=\"3695\" data-end=\"3747\">GHR-01A Testues i rezistenc\u00ebs hidrolitike t\u00eb kokrrave t\u00eb qelqit<\/strong>. Ai automatizon <strong data-start=\"3766\" data-end=\"3808\">procesi i th\u00ebrrmimit dhe sitjes vibruese<\/strong>, duke siguruar p\u00ebrgatitje t\u00eb mostrave t\u00eb p\u00ebrs\u00ebritshme dhe t\u00eb sakta.<br><strong data-start=\"3864\" data-end=\"3881\">Karakteristikat kryesore:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"3885\" data-end=\"3919\">Shkat\u00ebrrim dhe sitje automatike<\/strong>: Siguron uniformitetin e mostr\u00ebs dhe p\u00ebrputhshm\u00ebrin\u00eb me standardet ISO.<\/li>\n\n\n\n<li><strong data-start=\"3984\" data-end=\"4007\">Nd\u00ebrfaqja HMI me prekje<\/strong>: P\u00ebrmir\u00ebson kontrollin e p\u00ebrdoruesit dhe leht\u00ebsin\u00eb e p\u00ebrdorimit.<\/li>\n\n\n\n<li><strong data-start=\"4056\" data-end=\"4075\">Karakteristikat e Siguris\u00eb<\/strong>Mbrojt\u00ebset kund\u00ebr shp\u00ebrthimit t\u00eb xhamit dhe sistemet e mbledhjes s\u00eb mbeturinave p\u00ebrmir\u00ebsojn\u00eb sigurin\u00eb dhe past\u00ebrtin\u00eb n\u00eb laborator.<\/li>\n\n\n\n<li><strong data-start=\"4167\" data-end=\"4195\">Sakt\u00ebsi dhe Efikasitet<\/strong>Sivimi automatik siguron mostra testimi m\u00eb t\u00eb q\u00ebndrueshme dhe minimizon gabimet njer\u00ebzore.<a href=\"https:\/\/www.packqc.com\/sq\/product\/sale-glass-grain-hydrolytic-resistance-tester\/\"> <\/a><\/li>\n<\/ul>\n\n\n\n<p>GHR-01A rekomandohet fuqimisht p\u00ebr laborator\u00ebt dhe kompanit\u00eb farmaceutike q\u00eb duan t\u00eb p\u00ebrmbushin standardin ISO 719 dhe t\u00eb thjesht\u00ebzojn\u00eb proceset e kontrollit t\u00eb cil\u00ebsis\u00eb.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\n\t\t\t\tNa kontaktoni p\u00ebr zgjidhjen e testimit ISO 719\t\t\t\t<\/h2>\n\n\n\n<p>ISO 719 luan nj\u00eb rol thelb\u00ebsor n\u00eb kualifikimin dhe klasifikimin e materialeve t\u00eb qelqit t\u00eb p\u00ebrdorura n\u00eb paketimin farmaceutik. Duke ndjekur procedurat e k\u00ebtij standardi, prodhuesit dhe laborator\u00ebt mund t\u00eb vler\u00ebsojn\u00eb me sakt\u00ebsi <strong data-start=\"5254\" data-end=\"5279\">rezistenc\u00eb hidrolitike<\/strong>, p\u00ebrmir\u00ebso <strong data-start=\"5289\" data-end=\"5310\">sigurimi i cil\u00ebsis\u00eb<\/strong>, dhe sigurojn\u00eb p\u00ebrputhshm\u00ebrin\u00eb me rregulloret. Me instrumente si Cell Instruments\u2019 <strong data-start=\"5386\" data-end=\"5397\">GHR-01A<\/strong>, procesi i testimit b\u00ebhet m\u00eb efikas, m\u00eb i sigurt dhe m\u00eb i besuesh\u00ebm\u2014duke i mund\u00ebsuar laboratorit tuaj t\u00eb ruaj\u00eb standardet m\u00eb t\u00eb larta n\u00eb sigurin\u00eb dhe performanc\u00ebn e produktit.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pyetjet e shpeshta<\/h2>\n\n\n\n<p>1. Cili \u00ebsht\u00eb q\u00ebllimi i ISO 719?<br>ISO 719 p\u00ebrdoret p\u00ebr t\u00eb vler\u00ebsuar rezistenc\u00ebn hidrolitike t\u00eb grimcave t\u00eb qelqit n\u00eb 98\u00b0C, duke ndihmuar n\u00eb klasifikimin e q\u00ebndrueshm\u00ebris\u00eb kimike t\u00eb llojeve t\u00eb qelqit, ve\u00e7an\u00ebrisht qelqit soda-kalk.<\/p>\n\n\n\n<p>2. \u00c7far\u00eb llojesh xhami jan\u00eb t\u00eb p\u00ebrshtatshme p\u00ebr testimin sipas ISO 719?<br>Standardi zbatohet p\u00ebr xhama me rezistenc\u00eb kimike t\u00eb ul\u00ebt, kryesisht xhami sod\u00eb-kalk. Llojet m\u00eb rezistente, si xhami borosilikat, duhet t\u00eb testohen sipas ISO 720.<\/p>\n\n\n\n<p>3. Cila madh\u00ebsi e mostr\u00ebs k\u00ebrkohet p\u00ebr testimin sipas ISO 719?<br>T\u00eb pakt\u00ebn 2 gram\u00eb kokrra p\u00ebr \u00e7do test jan\u00eb t\u00eb nevojshme, me madh\u00ebsi kokrrash midis 300 \u00b5m dhe 500 \u00b5m.<\/p>\n\n\n\n<p>4. Si e p\u00ebrmir\u00ebson GHR-01A testimin sipas ISO 719?<br>GHR-01A automatizon proceset e th\u00ebrrmimit dhe t\u00eb sitjes, p\u00ebrmir\u00ebson sakt\u00ebsin\u00eb, redukton gabimet manuale dhe rrit sigurin\u00eb dhe efikasitetin n\u00eb laborator.<\/p>\n\n\n\n<p>5. \u00c7far\u00eb tregon nj\u00eb rezistenc\u00eb e lart\u00eb hidrolitike?<br>Rezistenca e lart\u00eb do t\u00eb thot\u00eb nxjerrje t\u00eb ul\u00ebt t\u00eb alkalive, duke treguar se qelqi \u00ebsht\u00eb kimikisht i q\u00ebndruesh\u00ebm dhe i p\u00ebrshtatsh\u00ebm p\u00ebr aplikime farmaceutike.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u00c7far\u00eb \u00ebsht\u00eb ISO 719? ISO 719:2020 \u00ebsht\u00eb standardi nd\u00ebrkomb\u00ebtar me titull \u201cXhami \u2014 Rezistenca hidrolytike e grimcave t\u00eb xhamit n\u00eb 98 \u00b0C \u2014 Metoda e testimit dhe klasifikimi.\u201d Ai p\u00ebrcakton nj\u00eb procedur\u00eb p\u00ebr testimin e rezistenc\u00ebs s\u00eb grimcave t\u00eb xhamit ndaj ujit n\u00eb temperatura t\u00eb larta. Testi mat v\u00ebllimin e acidit t\u00eb nevojsh\u00ebm p\u00ebr t\u00eb neutralizuar alkalin e nxjerr\u00eb [\u2026]<\/p>","protected":false},"featured_media":5519,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"standard-category":[612],"class_list":["post-9834","standard","type-standard","status-publish","has-post-thumbnail","hentry","standard-category-iso"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/sq\/wp-json\/wp\/v2\/standard\/9834","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/sq\/wp-json\/wp\/v2\/standard"}],"about":[{"href":"https:\/\/www.packqc.com\/sq\/wp-json\/wp\/v2\/types\/standard"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/sq\/wp-json\/wp\/v2\/media\/5519"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/sq\/wp-json\/wp\/v2\/media?parent=9834"}],"wp:term":[{"taxonomy":"standard-category","embeddable":true,"href":"https:\/\/www.packqc.com\/sq\/wp-json\/wp\/v2\/standard-category?post=9834"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}