{"id":9584,"date":"2026-02-02T14:53:24","date_gmt":"2026-02-02T06:53:24","guid":{"rendered":"https:\/\/www.packqc.com\/products\/syringe-liquid-leak-tester-iso-7886-1\/"},"modified":"2026-04-16T15:20:05","modified_gmt":"2026-04-16T07:20:05","slug":"syringe-liquid-leak-tester-iso-7886-1","status":"publish","type":"products","link":"https:\/\/www.packqc.com\/tr\/products\/syringe-liquid-leak-tester-iso-7886-1\/","title":{"rendered":"SPPT-01 \u015e\u0131r\u0131nga Pozitif Bas\u0131n\u00e7 S\u0131zd\u0131rmazl\u0131k Test Cihaz\u0131"},"content":{"rendered":"<p>Tek kullan\u0131ml\u0131k \u015f\u0131r\u0131ngalar\u0131n b\u00fct\u00fcnl\u00fc\u011f\u00fcn\u00fcn sa\u011flanmas\u0131, ila\u00e7 ve t\u0131bbi cihaz \u00fcretiminde hasta g\u00fcvenli\u011fi ve \u00fcr\u00fcn kalitesi a\u00e7\u0131s\u0131ndan kritik \u00f6neme sahiptir. En \u00f6nemli de\u011ferlendirmeler aras\u0131nda <strong data-start=\"593\" data-end=\"621\">\u015f\u0131r\u0131nga s\u0131v\u0131 s\u0131z\u0131nt\u0131 testi<\/strong>\u00f6zellikle s\u0131k\u0131\u015ft\u0131rma alt\u0131ndaki piston durdurucusunda. Bu test, piston kontroll\u00fc ko\u015fullar alt\u0131nda hem eksenel hem de radyal kuvvetlere maruz kald\u0131\u011f\u0131nda herhangi bir s\u0131z\u0131nt\u0131n\u0131n meydana gelip gelmedi\u011fini do\u011frular. Cell Instruments, bu testi hassasiyet ve tekrarlanabilirlikle ger\u00e7ekle\u015ftirmek i\u00e7in geli\u015fmi\u015f bir \u00e7\u00f6z\u00fcm sunar-<strong data-start=\"914\" data-end=\"972\">SPPT-01 \u015e\u0131r\u0131nga Pozitif Bas\u0131n\u00e7 S\u0131zd\u0131rmazl\u0131k Test Cihaz\u0131<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u015e\u0131r\u0131nga S\u0131v\u0131 Ka\u00e7ak Test Cihaz\u0131 - ISO 7886-1<\/h2>\n\n\n\n<p>ISO 7886-1 Ek D ile uyumluluk arayan laboratuvarlar ve \u00fcreticiler i\u00e7in <strong data-start=\"3251\" data-end=\"3305\">SPPT-01 \u015e\u0131r\u0131nga Pozitif Bas\u0131n\u00e7 S\u0131zd\u0131rmazl\u0131k Test Cihaz\u0131<\/strong> taraf\u0131ndan <strong data-start=\"3309\" data-end=\"3329\">H\u00fccre Enstr\u00fcmanlar\u0131<\/strong> tam otomatik ve hassas bir test \u00e7\u00f6z\u00fcm\u00fc sunar. Bir ile tasarlanm\u0131\u015ft\u0131r <strong data-start=\"3403\" data-end=\"3428\">PLC kontroll\u00fc sistem<\/strong> Ve <strong data-start=\"3433\" data-end=\"3465\">7 in\u00e7 dokunmatik ekran aray\u00fcz\u00fc<\/strong>SPPT-01 \u015funlar\u0131 sunar:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"3490\" data-end=\"3516\">Ayarlanabilir test h\u0131zlar\u0131<\/strong> (1-500 mm\/dak)<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3534\" data-end=\"3563\">Y\u00fcksek do\u011frulukta \u00f6l\u00e7\u00fcm<\/strong> (0,01 mm)<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3576\" data-end=\"3604\">De\u011fi\u015ftirilebilir armat\u00fcrler<\/strong> \u00e7e\u015fitli \u015f\u0131r\u0131nga boyutlar\u0131 i\u00e7in<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3633\" data-end=\"3676\">Yana ve a\u015fa\u011f\u0131 do\u011fru kuvvet uygulamas\u0131<\/strong> tek bir entegre platformda<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3706\" data-end=\"3729\">A\u015f\u0131r\u0131 y\u00fck korumas\u0131<\/strong> Ve <strong style=\"font-size: 16px;\" data-start=\"3734\" data-end=\"3754\">otomatik geri d\u00f6n\u00fc\u015f<\/strong> geli\u015fmi\u015f g\u00fcvenlik i\u00e7in<\/li>\n\n\n\n<li>Yerle\u015fik <strong style=\"font-size: 16px;\" data-start=\"3786\" data-end=\"3802\">mikro yaz\u0131c\u0131<\/strong> an\u0131nda test raporlamas\u0131 i\u00e7in<\/li>\n<\/ul>\n\n\n\n<p>Bu \u00f6zellikler tutarl\u0131l\u0131k, do\u011fruluk ve a\u015fa\u011f\u0131daki gibi k\u00fcresel d\u00fczenleyici standartlara ba\u011fl\u0131l\u0131k sa\u011flar <strong data-start=\"3928\" data-end=\"3942\">ISO 7886-1<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Ana Parametre<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Y\u00fck H\u00fccresi<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">200N (veya gerekti\u011fi gibi)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>H\u0131z Testi<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">1~500mm\/dak<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Kesinlik<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">0,01 mm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>G\u00fc\u00e7<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">110~220V<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Uygulamalar ve Sekt\u00f6rel Uygunluk<\/h2>\n\n\n\n<p>\u015e\u0131r\u0131nga s\u0131v\u0131 s\u0131z\u0131nt\u0131 testi \u00fcreticileri i\u00e7in ge\u00e7erlidir:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Hipodermik \u015f\u0131r\u0131ngalar<\/li>\n\n\n\n<li>\u00d6nceden doldurulmu\u015f \u015f\u0131r\u0131ngalar<\/li>\n\n\n\n<li>T\u0131bbi enjeksiyon sistemleri<\/li>\n\n\n\n<li>Kalite denetimi ve d\u00fczenleyici test laboratuvarlar\u0131<\/li>\n<\/ul>\n\n\n\n<p>\u015eirketler bu testi kalite kontrol protokollerine dahil ederek <strong data-start=\"4253\" data-end=\"4271\">farmas\u00f6tik<\/strong>, <strong data-start=\"4273\" data-end=\"4291\">tibbi\u0307 ci\u0307haz<\/strong>, Ve <strong data-start=\"4297\" data-end=\"4318\">ambalaj sekt\u00f6rleri\u0307<\/strong> uluslararas\u0131 d\u00fczenleyici gereklilikleri kar\u015f\u0131layabilir ve \u00fcr\u00fcn g\u00fcvenilirli\u011fini g\u00fc\u00e7lendirebilir.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u015e\u0131r\u0131nga S\u0131v\u0131 Ka\u00e7ak Testinin \u00d6nemi<\/h2>\n\n\n\n<p>\u015e\u0131r\u0131nga s\u0131v\u0131 s\u0131z\u0131nt\u0131 testi, steril hipodermik \u015f\u0131r\u0131ngalar\u0131n \u00fcretiminde kalite g\u00fcvencesi i\u00e7in gereklidir. S\u0131zd\u0131ran bir \u015f\u0131r\u0131nga, kontaminasyon, yanl\u0131\u015f dozajlama ve uygulama s\u0131ras\u0131nda ba\u015far\u0131s\u0131zl\u0131k gibi \u00f6nemli riskler olu\u015fturur. Kontroll\u00fc bir test ger\u00e7ekle\u015ftirerek <strong data-start=\"1288\" data-end=\"1316\">\u015f\u0131r\u0131nga s\u0131v\u0131 s\u0131z\u0131nt\u0131 testi<\/strong>\u00fcreticiler \u015f\u0131r\u0131ngan\u0131n piston t\u0131pas\u0131 tasar\u0131m\u0131ndaki zay\u0131fl\u0131klar\u0131 tespit edebilir ve kusurlu birimlerin pazara ula\u015fmas\u0131n\u0131 \u00f6nleyebilir.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">ISO 7886-1 Ek D'ye Dayal\u0131 Test Y\u00f6ntemi<\/h2>\n\n\n\n<p><a href=\"https:\/\/www.packqc.com\/tr\/product-category\/iso\/iso-7886-1\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"1506\" data-end=\"1520\">ISO 7886-1<\/strong><\/a> tek kullan\u0131ml\u0131k steril hipodermik \u015f\u0131r\u0131ngalar i\u00e7in uluslararas\u0131 standartt\u0131r. Bu standart <strong data-start=\"1603\" data-end=\"1625\">ISO 7886-1 testi<\/strong> prosed\u00fcr\u00fc, s\u0131z\u0131nt\u0131 direnci de dahil olmak \u00fczere \u015f\u0131r\u0131ngan\u0131n mekanik ve i\u015flevsel performans\u0131n\u0131 sa\u011flar. Spesifik olarak, <strong data-start=\"1746\" data-end=\"1768\">ISO 7886-1 Ek D<\/strong> ana hatlar\u0131yla <strong data-start=\"1782\" data-end=\"1865\">baski altindaki\u0307 \u015firinga pistonu durdurucusundaki\u0307 sivi sizintisi i\u0307\u00e7i\u0307n test y\u00f6ntemi\u0307<\/strong>.<\/p>\n\n\n\n<p><strong data-start=\"1506\" data-end=\"1520\">ISO 7886-1<\/strong> tek kullan\u0131ml\u0131k steril hipodermik \u015f\u0131r\u0131ngalar i\u00e7in uluslararas\u0131 standartt\u0131r. Bu standart <strong data-start=\"1603\" data-end=\"1625\">ISO 7886-1 testi<\/strong> prosed\u00fcr\u00fc, s\u0131z\u0131nt\u0131 direnci de dahil olmak \u00fczere \u015f\u0131r\u0131ngan\u0131n mekanik ve i\u015flevsel performans\u0131n\u0131 sa\u011flar. Spesifik olarak, <strong data-start=\"1746\" data-end=\"1768\">ISO 7886-1 Ek D<\/strong> ana hatlar\u0131yla <strong data-start=\"1782\" data-end=\"1865\">baski altindaki\u0307 \u015firinga pistonu durdurucusundaki\u0307 sivi sizintisi i\u0307\u00e7i\u0307n test y\u00f6ntemi\u0307<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">ISO 7886-1 Ek D'den Test Prensipleri<\/h2>\n\n\n\n<p>Ek D prosed\u00fcr\u00fc, \u015f\u0131r\u0131nga pistonu \u00fczerindeki eksenel ve radyal y\u00fckleri birle\u015ftirerek en k\u00f6t\u00fc durum ko\u015fullar\u0131n\u0131 sim\u00fcle etmeyi ama\u00e7lamaktad\u0131r:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u015e\u0131r\u0131nga \u00f6nce a\u015fa\u011f\u0131dakilerle doldurulur <strong data-start=\"2076\" data-end=\"2095\">dam\u0131t\u0131lm\u0131\u015f su<\/strong> nominal kapasitesinin \u00fczerinde.<\/li>\n\n\n\n<li>Havay\u0131 d\u0131\u015far\u0131 att\u0131ktan sonra, hacim nominal seviyeye ayarlan\u0131r.<\/li>\n\n\n\n<li>Nozul bir conta kullan\u0131larak kapat\u0131l\u0131r <strong style=\"font-size: 16px;\" data-start=\"2223\" data-end=\"2252\">referans konik ba\u011flant\u0131 par\u00e7as\u0131<\/strong> ISO 80369-7 veya e\u015fde\u011fer bir contaya uygun olarak.<\/li>\n\n\n\n<li>A <strong style=\"font-size: 16px;\" data-start=\"2311\" data-end=\"2329\">yana do\u011fru kuvvet<\/strong> (0,25 N ila 3 N) sapmaya neden olmak i\u00e7in pistona uygulan\u0131r.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"2396\" data-end=\"2414\">Eksenel bas\u0131n\u00e7<\/strong> 200-300 kPa aral\u0131\u011f\u0131nda \u00fcretilir ve 30-35 saniye boyunca muhafaza edilir.<\/li>\n\n\n\n<li>Herhangi bir <strong style=\"font-size: 16px;\" data-start=\"2496\" data-end=\"2532\">piston t\u0131pas\u0131n\u0131 ge\u00e7en s\u0131z\u0131nt\u0131<\/strong> g\u00f6rsel olarak incelenir.<\/li>\n<\/ul>\n\n\n\n<p>Bu metodoloji, piston durdurucunun bas\u0131n\u00e7 ve yanal stres alt\u0131nda s\u0131k\u0131 bir s\u0131zd\u0131rmazl\u0131k sa\u011flamas\u0131n\u0131 sa\u011flayarak ar\u0131zaya neden olabilecek ger\u00e7ek d\u00fcnya ko\u015fullar\u0131n\u0131 taklit eder.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">ISO 7886-1 Ek D Testi i\u00e7in Ekipman Gereklilikleri<\/h2>\n\n\n\n<p>\u015e\u0131r\u0131nga s\u0131v\u0131 s\u0131z\u0131nt\u0131 testini do\u011fru bir \u015fekilde ger\u00e7ekle\u015ftirmek i\u00e7in a\u015fa\u011f\u0131daki ekipman gereklidir:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u015e\u0131r\u0131nga memesi i\u00e7in bir s\u0131zd\u0131rmazl\u0131k cihaz\u0131.<\/li>\n\n\n\n<li>Pistona radyal kuvvet uygulamak i\u00e7in bir fikst\u00fcr.<\/li>\n\n\n\n<li>200-300 kPa'ya ula\u015fmak i\u00e7in bir bas\u0131n\u00e7land\u0131rma cihaz\u0131.<\/li>\n\n\n\n<li>Doldurma i\u015flemi i\u00e7in dam\u0131t\u0131lm\u0131\u015f su (18\u00b0C ila 28\u00b0C).<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">SSS<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u015e\u0131r\u0131nga s\u0131v\u0131 s\u0131z\u0131nt\u0131 testi ne i\u00e7in kullan\u0131l\u0131r?<br>\u015e\u0131r\u0131nga s\u0131v\u0131 s\u0131z\u0131nt\u0131 testi, piston t\u0131pas\u0131n\u0131n s\u0131k\u0131\u015ft\u0131rma alt\u0131nda uygun bir s\u0131zd\u0131rmazl\u0131k sa\u011flay\u0131p sa\u011flamad\u0131\u011f\u0131n\u0131 de\u011ferlendirerek steriliteyi veya dozaj do\u011frulu\u011funu tehlikeye atabilecek herhangi bir s\u0131z\u0131nt\u0131y\u0131 \u00f6nler.<\/li>\n\n\n\n<li>Cell Instruments\u2019 SPPT-01 testi nas\u0131l ger\u00e7ekle\u015ftiriyor?<br>SPPT-01 test cihaz\u0131, en k\u00f6t\u00fc durum ko\u015fullar\u0131n\u0131 sim\u00fcle ederek t\u0131pay\u0131 ge\u00e7en herhangi bir s\u0131z\u0131nt\u0131y\u0131 tespit etmek i\u00e7in noz\u00fcl s\u0131zd\u0131rmazken \u015f\u0131r\u0131nga pistonuna hem radyal hem de eksenel kuvvetler uygular.<\/li>\n\n\n\n<li>Bu test kalite kontrol i\u00e7in neden \u00f6nemlidir?<br>Her \u015f\u0131r\u0131ngan\u0131n ilac\u0131 g\u00fcvenli ve do\u011fru bir \u015fekilde vermesini sa\u011flayarak kontaminasyonu, dozaj kayb\u0131n\u0131 veya enjeksiyon hatalar\u0131n\u0131 \u00f6nler.<\/li>\n\n\n\n<li>SPPT-01 farkl\u0131 \u015f\u0131r\u0131nga boyutlar\u0131 i\u00e7in kullan\u0131labilir mi?<br>Evet, SPPT-01 \u00e7ok \u00e7e\u015fitli \u015f\u0131r\u0131nga t\u00fcrlerini ve kapasitelerini bar\u0131nd\u0131rmak i\u00e7in birden fazla fikst\u00fcrle birlikte gelir ve farkl\u0131 test ihtiya\u00e7lar\u0131 i\u00e7in \u00e7ok y\u00f6nl\u00fcl\u00fc\u011f\u00fcn\u00fc art\u0131r\u0131r.<\/li>\n<\/ol>\n\n\n\n<p>Bir \u015f\u0131r\u0131ngan\u0131n bas\u0131n\u00e7 alt\u0131nda s\u0131zd\u0131rmazl\u0131\u011f\u0131n\u0131 koruyabilmesini sa\u011flamak g\u00fcvenlik ve performans i\u00e7in \u00e7ok \u00f6nemlidir. Bu <strong data-start=\"4543\" data-end=\"4571\">\u015f\u0131r\u0131nga s\u0131v\u0131 s\u0131z\u0131nt\u0131 testi<\/strong>'de tan\u0131mland\u0131\u011f\u0131 gibi <strong data-start=\"4587\" data-end=\"4609\"><a href=\"https:\/\/www.iso.org\/standard\/64790.html\" target=\"_blank\" rel=\"noopener nofollow\">ISO 7886-1<\/a> Ek D<\/strong>bu kritik \u00f6zelli\u011fi de\u011ferlendirmek i\u00e7in standartla\u015ft\u0131r\u0131lm\u0131\u015f ve g\u00fcvenilir bir y\u00f6ntem sa\u011flar. gibi hassas ve tam uyumlu bir cihaz kullanarak <strong data-start=\"4747\" data-end=\"4801\">SPPT-01 \u015e\u0131r\u0131nga Pozitif Bas\u0131n\u00e7 S\u0131zd\u0131rmazl\u0131k Test Cihaz\u0131<\/strong> itibaren <strong data-start=\"4807\" data-end=\"4827\">H\u00fccre Enstr\u00fcmanlar\u0131<\/strong> \u00fcreticilerin kalite standartlar\u0131n\u0131 s\u00fcrd\u00fcrmelerine ve son kullan\u0131c\u0131lar\u0131 korumalar\u0131na yard\u0131mc\u0131 olur.<\/p>","protected":false},"excerpt":{"rendered":"<p>Ensuring the integrity of disposable syringes is critical for patient safety and product quality in pharmaceutical and medical device manufacturing. Among the most important assessments is the syringe liquid leak test, particularly at the plunger stopper under compression. This test verifies whether any leakage occurs when the plunger is subjected to both axial and radial [&hellip;]<\/p>","protected":false},"featured_media":0,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"product-category":[484,438,593],"product-tag":[],"class_list":["post-9584","products","type-products","status-publish","hentry","product-category-leak-testing","product-category-medical-and-pharmaceutical-testing","product-category-syringe-testing"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/tr\/wp-json\/wp\/v2\/products\/9584","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/tr\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.packqc.com\/tr\/wp-json\/wp\/v2\/types\/products"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/tr\/wp-json\/wp\/v2\/media?parent=9584"}],"wp:term":[{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/www.packqc.com\/tr\/wp-json\/wp\/v2\/product-category?post=9584"},{"taxonomy":"product-tag","embeddable":true,"href":"https:\/\/www.packqc.com\/tr\/wp-json\/wp\/v2\/product-tag?post=9584"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}