{"id":9582,"date":"2026-02-02T14:53:24","date_gmt":"2026-02-02T06:53:24","guid":{"rendered":"https:\/\/www.packqc.com\/products\/needle-toughness-tester\/"},"modified":"2026-04-16T10:11:17","modified_gmt":"2026-04-16T02:11:17","slug":"needle-toughness-tester","status":"publish","type":"products","link":"https:\/\/www.packqc.com\/uz\/products\/needle-toughness-tester\/","title":{"rendered":"NTT-01 igna mustahkamligini sinovchi"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Ig'naning sinishga chidamliligiga kirish<\/h2>\n\n\n\n<p>Ta'minlash <em data-start=\"453\" data-end=\"484\">Ig'naning sinishga qarshiligi<\/em> tibbiyot qurilmalarining xavfsizligi va ishonchliligining muhim qismi bo'lib, ayniqsa gipodermik ignalar uchun zarurdir. Ishlatish paytida sinib ketishi jiddiy jarohatlarga, ifloslanishga yoki mahsulotning nosozligiga olib kelishi mumkin. <strong data-start=\"720\" data-end=\"754\">NTT-01 igna mustahkamligini sinovchi<\/strong> Cell Instruments aniq, <b>ISO 9626 <\/b>Zanglamaydigan po'lat igna trubkasining mexanik mustahkamligini tekshirish uchun eritma.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Nega igna sinishga chidamlilikni sinash muhimdir<\/h2>\n\n\n\n<p>Tibbiyot asboblari ishlab chiqarish sohasida, xususan igna va kateterlar uchun, foydalanish paytida mexanik nosozliklar jiddiy xavf tug'diradi. <em data-start=\"1443\" data-end=\"1474\">Ig'naning sinishga qarshiligi<\/em> Bemor xavfsizligi va mahsulot yaxlitligini ta'minlash uchun tasdiqlanishi kerak. Ga ko'ra <strong data-start=\"1554\" data-end=\"1571\"><a href=\"https:\/\/www.packqc.com\/uz\/product-category\/iso\/iso-9626\/\" target=\"_blank\" rel=\"noopener\">ISO 9626<\/a>:2016<\/strong>, Tibbiyot qurilmalarida ishlatiladigan zanglamaydigan po'lat ignali naychalar bosim ostida chidamliligini tasdiqlash uchun qat'iy sinovlardan o'tishi kerak.<\/p>\n\n\n\n<p>Ushbu standart, xususan <em data-start=\"1728\" data-end=\"1737\">Ilova C<\/em>, baholashning batafsil usulini bayon etadi <em data-start=\"1782\" data-end=\"1816\">Turibaning sinishga qarshiligi<\/em>. Ushbu talablarga rioya qilish orqali ishlab chiqaruvchilar nafaqat muvofiqlikni ta'minlaydi, balki mahsulotlarining bozor ishonchliligini ham oshiradi.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Quvurlarning sinishga chidamliligi \u2013 ISO 9626 ilovasi C sinov usuli<\/h2>\n\n\n\n<p>Belish sinovi aniqlangan <strong data-start=\"2060\" data-end=\"2080\"><a href=\"https:\/\/www.packqc.com\/uz\/standard\/iso-9626\/\" target=\"_blank\" data-type=\"standard\" data-id=\"9825\" rel=\"noreferrer noopener\">ISO 9626<\/a> Ilova C<\/strong> Ushbu sinov shlangning bir uchini mahkam ushlab, belgilangan masofada nazorat ostida kuch qo'llash orqali shlangni ikkala yo'nalishda ham belgilangan burchak ostida egishni o'z ichiga oladi. Bu sinov igna haqiqiy klinik foydalanishda duch keladigan kuchlanishlarni taqlid qiladi.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"2328\" data-end=\"2346\">Egish burchaklari<\/strong>:\n<ul class=\"wp-block-list\">\n<li><em style=\"font-size: 16px;\" data-start=\"2354\" data-end=\"2364\">(25 \u00b11)\u00b0<\/em> oddiy devorli quvurlar uchun<\/li>\n\n\n\n<li><em style=\"font-size: 16px;\" data-start=\"2397\" data-end=\"2407\">(20 \u00b11)\u00b0<\/em> Yupqa devorli quvurlar uchun<\/li>\n\n\n\n<li><em style=\"font-size: 16px;\" data-start=\"2437\" data-end=\"2447\">(15 \u00b11)\u00b0<\/em> Qalinligi juda ingichka va ultra-ingichka devorli quvurlar uchun<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"2497\" data-end=\"2512\">Sinov tsikllari<\/strong>:<br>Oldinga va orqaga egilishning 20 to'liq tsikli<\/li>\n\n\n\n<li><strong data-start=\"2572\" data-end=\"2590\">Sinov chastotasi<\/strong>:<br>0,5 gerts<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\" style=\"margin-top:0;margin-bottom:0\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"Needle Tough Test with interval in the middle| Left and Right Bending\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/adX7tiXymqw?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<\/div><\/figure>\n\n\n\n<p>Sinovdan so'ng igna sinib ketish belgilarini aniqlash uchun vizual tekshiriladi. Ushbu protsedura quvurlarning chidamliligini baholash uchun standartlashtirilgan usulni taklif etadi, bu esa sifat nazorati va me'yoriy talablarga muvofiqlikni ta'minlashga yordam beradi.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">NTT-01 igna mustahkamligini sinovdan o'tkazish moslamasini taqdim etamiz<\/h2>\n\n\n\n<p>The <strong data-start=\"2870\" data-end=\"2904\">NTT-01 <a href=\"https:\/\/www.packqc.com\/uz\/product\/needle-toughness-tester\/\">Igna mustahkamligini sinovchi<\/a><\/strong> ISO 9626 ilova C sinov usulini yuqori aniqlik va foydalanuvchiga qulay boshqaruvlar bilan bajarish uchun mo'ljallangan. Bu ishlab chiqaruvchilarga baholash imkonini beradi <em data-start=\"3048\" data-end=\"3079\">Ig'naning sinishga qarshiligi<\/em> Turli qalinlikdagi quvur devorlarida izchillik va aniqlik bilan.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong data-start=\"3151\" data-end=\"3172\">Ishlash mexanizmi<\/strong><\/h3>\n\n\n\n<p>Uskuna quvur bir uchini qat'iy mahkamlaydi va belgilangan nuqtada kuch qo'llab, quvurni kerakli burchakka egadi. Keyin tizim yo'nalishni teskari tomonga o'zgartirib, jarayonni takrorlaydi hamda test chastotasi va burchak chegaralarini avtomatik boshqaradi.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Ig'na mustahkamligini sinovchi asbobning asosiy xususiyatlari<\/h2>\n\n\n\n<p>Ushbu asbob tadqiqot laboratoriyalari, ishlab chiqarish liniyalari va sifat nazorati bo'limlari uchun ideal.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong data-start=\"3584\" data-end=\"3623\">HMI sensorli ekrani bilan PLC boshqariladi<\/strong>: Intuitiv boshqaruv va sozlashni ta'minlaydi.<\/li>\n\n\n\n<li><strong style=\"font-size: 16px;\" data-start=\"3676\" data-end=\"3713\">Ikki yo'nalishli va bir yo'nalishli egilish rejimlari<\/strong>: Ikkala test talablarini ham qo'llab-quvvatlaydi.<\/li>\n\n\n\n<li><strong style=\"font-style: inherit;\" data-start=\"3752\" data-end=\"3782\">Sozlanadigan test parametrlari<\/strong>: chastota, turish vaqti va egilish burchagini o'z ichiga oladi.<\/li>\n\n\n\n<li><strong style=\"font-style: inherit;\" data-start=\"3840\" data-end=\"3869\">Avtomatik qaytish funksiyasi<\/strong>: Hatto quvvat uzilganda ham test yaxlitligini ta'minlaydi.<\/li>\n\n\n\n<li><strong style=\"font-style: inherit;\" data-start=\"3932\" data-end=\"3959\">Integratsiyalashgan mikroprinter<\/strong>: Test natijalarini darhol hujjatlashtirish uchun.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Asosiy texnik parametrlar<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Parametr<\/th><th>Spetsifikatsiya<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">Egish rejimi<\/td><td class=\"has-text-align-center\" data-align=\"center\">Ikki tomonlama, bir tomonlama<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Egish burchagi<\/td><td class=\"has-text-align-center\" data-align=\"center\">15\u00b0, 20\u00b0, 25\u00b0<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Sinov chastotasi<\/td><td class=\"has-text-align-center\" data-align=\"center\">0,5 gerts<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Quvvatlantirish manbai<\/td><td class=\"has-text-align-center\" data-align=\"center\">110 ~ 220 V<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Standart konfiguratsiya<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Igna mustahkamligini sinovchi<\/li>\n\n\n\n<li>Aniqlikli kaliper<\/li>\n\n\n\n<li>Quvvat kabeli<\/li>\n\n\n\n<li>Sug&#039;urta<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">Tibbiyot va unga aloqador sanoat sohalaridagi qo'llanilishi<\/h2>\n\n\n\n<p>NTT-01 asosan teri osti ignalari, kateterlar va naychalarni sinovdan o'tkazishda ishlatiladi. <strong data-start=\"4656\" data-end=\"4683\">tibbiy, farmatsevtika<\/strong>, va <strong data-start=\"4689\" data-end=\"4714\">shprits ishlab chiqarish<\/strong> sektorlar. Bu shuningdek keng qo'llaniladi <strong data-start=\"4756\" data-end=\"4787\">sifat nazorati agentliklari<\/strong>, yakuniy mahsulotlar xalqaro xavfsizlik standartlariga, masalan, muvofiq bo'lishini ta'minlaydi <a href=\"https:\/\/www.iso.org\/standard\/60480.html\" target=\"_blank\" rel=\"noopener nofollow\"><em data-start=\"4859\" data-end=\"4869\">ISO 9626<\/em><\/a>.<\/p>\n\n\n\n<p>Izlashni istagan kompaniyalar uchun <strong data-start=\"4899\" data-end=\"4931\">Sinov protseduralarini moslashtiring<\/strong> yoki sifat nazorati jarayonining bir qismini avtomatlashtirish uchun Cell Instruments aniqlikdan voz kechmasdan operatsiyalarni soddalashtirishga mo'ljallangan moslashtirilgan yechimlarni taklif etadi.<\/p>\n\n\n\n<p>Saqlash <em data-start=\"5129\" data-end=\"5160\">Ig'naning sinishga qarshiligi<\/em> Bu faqat tartibga soluvchi talab emas \u2014 bu mahsulot yaxlitligi va foydalanuvchi xavfsizligi masalasidir. <strong data-start=\"5256\" data-end=\"5290\">NTT-01 igna mustahkamligini sinovchi<\/strong>, Cell Instruments mukammallikka intilayotgan ishlab chiqaruvchilar uchun ilg'or va me'yoriy talablarga javob beradigan yechimni taqdim etadi. Siz standart tibbiy naychalarni yoki maxsus loyihalangan komponentlarni sinovdan o'tkazayotgan bo'lsangiz ham, NTT-01 barqaror ishlashni va xotirjamlikni ta'minlaydi.<\/p>\n\n\n\n<p>NTT-01 qanday qilib sinov standartlaringizni yaxshilashi mumkinligi haqida ko'proq ma'lumot olish yoki muhokama qilish uchun <strong data-start=\"5617\" data-end=\"5646\">avtomatlashtirish transformatsiyasi<\/strong> xizmatlar, aloqa <strong data-start=\"5665\" data-end=\"5695\"><a href=\"https:\/\/www.packqc.com\/uz\/\" target=\"_blank\" rel=\"noopener\">Hujayra asboblari<\/a> MChJ.<\/strong> bugun.<\/p>","protected":false},"excerpt":{"rendered":"<p>Ensuring needle resistance to breakage is a critical part of medical device safety and reliability, particularly for hypodermic needles.<\/p>","protected":false},"featured_media":5285,"parent":0,"template":"","meta":{"_acf_changed":true,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"product-category":[456,579,434,580,438,581,593],"product-tag":[],"class_list":["post-9582","products","type-products","status-publish","has-post-thumbnail","hentry","product-category-gb","product-category-gb-t-18457","product-category-iso","product-category-iso-9626","product-category-medical-and-pharmaceutical-testing","product-category-needle-toughness-tester","product-category-syringe-testing"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.packqc.com\/uz\/wp-json\/wp\/v2\/products\/9582","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packqc.com\/uz\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.packqc.com\/uz\/wp-json\/wp\/v2\/types\/products"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packqc.com\/uz\/wp-json\/wp\/v2\/media\/5285"}],"wp:attachment":[{"href":"https:\/\/www.packqc.com\/uz\/wp-json\/wp\/v2\/media?parent=9582"}],"wp:term":[{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/www.packqc.com\/uz\/wp-json\/wp\/v2\/product-category?post=9582"},{"taxonomy":"product-tag","embeddable":true,"href":"https:\/\/www.packqc.com\/uz\/wp-json\/wp\/v2\/product-tag?post=9582"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}